background image

 

Omikron CallHelp 500RP                                                                                                                                         2 

 

 

Omikron CallHelp 500RP Manual

    Versie: 1.09  

Omikron CallHelp 500RP Repeater* 

 
Technical information:  
 
Voltage adapter: 12V/1A  
Frequency: UHF 433.92Mhz.  
RF Power: 10Mw 
Standby: <40 hour ** 
Back-up battery: Lithium battery 3.7V 800Mah 
Standby current: 20Ma 
Transmitting current: 90Ma 
Charging time: 50 hour 
 
 
 
*For use with CallHelp Paging systems or Buttons with  
Alpha Numeric Tekst Messages. 
 
**Depending on usage. 
 

Non Waterproof. Waranty 1 year. Except damage from 
falling, when opened cabinet, modification, wrong use, 
broken screen. 

 
***We advise to replace every year the backup 
battery for reliable working. 
 

 

                          Conformity Statement 

 
Herewith we declare that the following product: 
 
Omikron CallHelp 500RP Repeater is meeting all EU requirements 
in accordance  Directive 2014/53/EU (RED)  
 
Product description:                 HF oproepzender 
ID Markering:  500RP              Class 1 Equipment 
 
In accordance: 
2014/53/EU European Radio Equipment Directive (RED) 
2011/65/EU Restriction of Hazardous Substances (RoHS) and that 
the following harmonized European standards are applied:  
Health and safety: EN 60 950-1:2006 + A11:2009 + A1:2010 + 
A12:2011 + AC:2011 + A2:2013 Electromagnetic compatibility:   
EN 301 489-1 : V2.1.1 EN 301 489-3 : V1.6.1 Use of the radio 
frequency spectrum: EN 300 220-2 : V3.1.1 Assessment of 
hazardous substances: EN 50581:2012 
 

 

 

 
Omikron Europe  
Theo Kwantenstraat 53 
3223CE  Hellevoetsluis 
The Netherlands 
tel.       00 31 (0) 642705689 

web:

http://www.omikron-europe.com

 

e-mail :

 [email protected]

 

 
Hellevoetsluis, 1.10.2019 

 

P. Konstapel CEO 

 

System Setup 

Charge fully before use. Turn on with on/off switch. 

1.6

 

Long press SET switch side until LED RED quickly activates PC Setup Mode. 

1.7

 

PC Setup mode, see manual PC software. Escape program setup pressing long SET or after 60 seconds 
automaticly. 

1.8

 

Press again short activates System Coding by 500TXxBTTN. LED flashes fast GREEN. Press a 500TXxBTTN. 
LED Flashes 1x GREEN. Escape program setup pressing long SET or after 60 seconds automaticly. 

1.9

 

Press again short activates Range TEST mode. LED flashes slowly GREEN. Activate Range Test on a 
500TX3BTTN or activate Range Test on a 400TX. The repeater wilt retransmit every received signal 1X. 
Test Range with 500RX in TEST mode. Escape program setup pressing long SET or after 60 seconds 
automaticly. 

1.10

 

 Press again short activates automatic RANGE TEST mode. LED flashes slowly  RED. During 20 minutes 
every 1 second a trasnmission is send. Test with 500RX or next 500RP in test mode the range. Escape 
program setup pressing long SET or after 60 seconds automaticly. 
 
With PC software you can setup the number of the repeater, automatic hourly control and  systemcode. 
 
Repeaters can be numbered sequential. System will test every hour if all repeaters are present. This will 
be visual on display of  400TX or in 500RX pager. 
 
If any repeater receives a signal transmission from any button in its range it will retransmit by all 
repeaters. Placement of repeaters is preferably sequential. 
 