Omikron CallHelp 500RP 2
Omikron CallHelp 500RP Manual
Versie: 1.09
Omikron CallHelp 500RP Repeater*
Technical information:
Voltage adapter: 12V/1A
Frequency: UHF 433.92Mhz.
RF Power: 10Mw
Standby: <40 hour **
Back-up battery: Lithium battery 3.7V 800Mah
Standby current: 20Ma
Transmitting current: 90Ma
Charging time: 50 hour
*For use with CallHelp Paging systems or Buttons with
Alpha Numeric Tekst Messages.
**Depending on usage.
Non Waterproof. Waranty 1 year. Except damage from
falling, when opened cabinet, modification, wrong use,
broken screen.
***We advise to replace every year the backup
battery for reliable working.
Conformity Statement
Herewith we declare that the following product:
Omikron CallHelp 500RP Repeater is meeting all EU requirements
in accordance Directive 2014/53/EU (RED)
Product description: HF oproepzender
ID Markering: 500RP Class 1 Equipment
In accordance:
2014/53/EU European Radio Equipment Directive (RED)
2011/65/EU Restriction of Hazardous Substances (RoHS) and that
the following harmonized European standards are applied:
Health and safety: EN 60 950-1:2006 + A11:2009 + A1:2010 +
A12:2011 + AC:2011 + A2:2013 Electromagnetic compatibility:
EN 301 489-1 : V2.1.1 EN 301 489-3 : V1.6.1 Use of the radio
frequency spectrum: EN 300 220-2 : V3.1.1 Assessment of
hazardous substances: EN 50581:2012
Omikron Europe
Theo Kwantenstraat 53
3223CE Hellevoetsluis
The Netherlands
tel. 00 31 (0) 642705689
e-mail :
Hellevoetsluis, 1.10.2019
P. Konstapel CEO
System Setup
Charge fully before use. Turn on with on/off switch.
1.6
Long press SET switch side until LED RED quickly activates PC Setup Mode.
1.7
PC Setup mode, see manual PC software. Escape program setup pressing long SET or after 60 seconds
automaticly.
1.8
Press again short activates System Coding by 500TXxBTTN. LED flashes fast GREEN. Press a 500TXxBTTN.
LED Flashes 1x GREEN. Escape program setup pressing long SET or after 60 seconds automaticly.
1.9
Press again short activates Range TEST mode. LED flashes slowly GREEN. Activate Range Test on a
500TX3BTTN or activate Range Test on a 400TX. The repeater wilt retransmit every received signal 1X.
Test Range with 500RX in TEST mode. Escape program setup pressing long SET or after 60 seconds
automaticly.
1.10
Press again short activates automatic RANGE TEST mode. LED flashes slowly RED. During 20 minutes
every 1 second a trasnmission is send. Test with 500RX or next 500RP in test mode the range. Escape
program setup pressing long SET or after 60 seconds automaticly.
With PC software you can setup the number of the repeater, automatic hourly control and systemcode.
Repeaters can be numbered sequential. System will test every hour if all repeaters are present. This will
be visual on display of 400TX or in 500RX pager.
If any repeater receives a signal transmission from any button in its range it will retransmit by all
repeaters. Placement of repeaters is preferably sequential.