Increasing the Output
Power
35
If, for a parallel connection, some CMA's are not used, the amplifiers not in use
• must stay in Power-ON condition or
• must be disconnected at "Ampl. in",
otherwise the input signal gets distorted by the amplifiers in the power-OFF
condition.
4 C M A parallel
1 C M A 5 6
Figure 11
Output power per CMA 56 phase and for parallel connection of 4
CMA amplifiers