7.1
OIL LEAKS
Oil leaks may appear at the joins in the pipes if a pipe
fitting or screw is loosened. Every 300 ÷ 400 working
hours, tighten the connecting screws of the flanges or
the nuts of the quick couplings.
An insufficient level of oil is signalled by the
INDUSTRIAL PC and by the resulting stopping of the
machine: the oil level will then need to be topped up.
7.2
OIL FILTER
The clogging of the oil filter is signalled by the
INDUSTRIAL PC.
In this case the machine does not stop but the
cartridge/filter should be replaced as soon as
possible.
The filter used is made by M.P. and is the following
type:
MPS 350 R G1 P10 A FX
(Omera code 76801060)
The cartridge used is made by M.P. and is the
following type:
CS 150 – P10A
(Omera Code 76801120)