background image

X (mm) 

Y(mm) 

Velocity 

– 

nominal velocity, 

150  (ft/min) 

Velocity 

– 

nominal velocity, 

800  (ft/min) 

10 

10 

138 

770 

10 

20 

154 

788 

10 

30 

153 

775 

10 

40 

153 

772 

20 

10 

153 

783 

20 

20 

157 

800 

20 

30 

155 

790 

20 

40 

158 

790 

30 

10 

153 

776 

30 

20 

158 

775 

30 

30 

155 

771 

30 

40 

151 

773 

40 

10 

153 

796 

40 

20 

153 

773 

40 

30 

152 

775 

40 

40 

158 

771 

60 

10 

154 

785 

60 

20 

152 

775 

60 

30 

153 

775 

60 

40 

152 

776 

90 

10 

154 

784 

90 

20 

153 

768 

90 

30 

154 

766 

90 

40 

155 

766 

120 

10 

155 

780 

120 

20 

153 

774 

120 

30 

155 

772 

120 

40 

153 

769 

150 

10 

154 

781 

150 

20 

154 

770 

150 

30 

153 

769 

150 

40 

154 

767 

202 

10 

154 

781 

202 

20 

154 

770 

202 

30 

153 

769 

202 

40 

154 

767 

 
 

Velocity distribution at the inlet of the test section for  

WT-3100 Wind Tunnel 

 

Summary of Contents for WT-3100

Page 1: ...omega com e mail info omega com For latest product manuals omegamanual info WT 3100 Controlled Open Loop Wind Tunnel Shop online at User sGuide...

Page 2: ...ged by the United Kingdom Office Toll Free 0800 466 342 TEL 33 0 161 37 29 00 FAX 33 0 130 57 54 27 e mail sales omega fr Germany Austria Daimlerstrasse 26 D 75392 Deckenpfronn Germany Toll Free 0 800...

Page 3: ...he front door for mounting of the boards A unique internal rail guides provide mechanisms for installation of test specimen of different sizes e g PCB heat sink Installation of different fan trays can...

Page 4: ...on Variable Speed Change the flow rate by controlling the fan RPM Flow Direction Test the effect of flow direction fan failure simulation by controlling the fans either variable RPM or on off Quick Ac...

Page 5: ...Figure 1 The WT 3100 System Components...

Page 6: ...variable DC power supply Voltage to the fans cannot exceed 26 Volts DC Adjust voltage until desired flow level is attained 5 Insert the velocity and temperature probes into the instrument ports provis...

Page 7: ...uadrant of the test section for two different velocity levels 0 75 m s and 4 m s 150 and 800 ft min respectively VELOCITY PROFILE WT 3100 test section top view Velocity measurement quadrant Velocity D...

Page 8: ...0 40 151 773 40 10 153 796 40 20 153 773 40 30 152 775 40 40 158 771 60 10 154 785 60 20 152 775 60 30 153 775 60 40 152 776 90 10 154 784 90 20 153 768 90 30 154 766 90 40 155 766 120 10 155 780 120...

Page 9: ...therwise shall not exceed the purchase price of the component upon which liability is based In no event shall OMEGA be liable for consequential incidental or special damages CONDITIONS Equipment sold...

Page 10: ...city Indicators Turbine Paddlewheel Systems Totalizers Batch Controllers pH CONDUCTIVITY pH Electrodes Testers Accessories Benchtop Laboratory Meters Controllers Calibrators Simulators Pumps Industria...

Reviews: