OMEGA | WATER SOURCE HEAT PUMPS  

                                                                       

OMEGA-VSHP.F-IOM-1907

 

 

 

37

 

www.omega-heatpump.com   

 

 

 

0

0.05

0.1

0.15

0.2

0.25

0.3

0.35

0.4

0.45

0.5

0.55

0.6

SCFM

SCFM

SCFM

SCFM

SCFM

SCFM

SCFM

SCFM

SCFM

SCFM

SCFM

SCFM

SCFM

WHISPER* 

M ODE

N/A

N/A

N/A

210

195

180

160

145

130

115

100

75

55

-

-

-

LOW

250

240

225

210

200

185

150

-

-

-

-

-

-

MED

-

-

255

240

225

215

200

190

175

165

150

-

-

MED

-

-

255

240

225

215

200

190

175

165

150

-

-

HIGH

-

-

-

-

260

240

230

220

210

195

185

175

165

WHISPER* 

M ODE

N/A

N/A

N/A

225

210

195

175

160

145

130

115

100

85

70

-

-

LOW

315

305

295

285

275

265

250

240

225

-

-

-

-

MED

350

340

335

325

315

305

295

285

275

265

255

245

235

MED

350

340

335

325

315

305

295

285

275

265

255

245

235

HIGH

-

-

365

355

350

340

330

320

310

305

295

285

275

WHISPER* 

M ODE

N/A

N/A

N/A

250

230

225

205

180

160

145

125

110

90

75

-

-

LOW

410

400

390

380

370

365

350

340

330

325

310

300

-

MED

460

450

445

440

430

425

415

405

395

385

375

365

355

MED

460

450

445

440

430

425

415

405

395

385

375

365

355

HIGH

-

-

-

-

470

465

455

445

435

430

420

410

400

WHISPER* 

M ODE

N/A

N/A

N/A

450

430

410

390

370

350

320

300

270

250

220

-

-

LOW

520

510

490

470

450

430

410

390

375

-

-

-

-

MED

-

-

550

540

520

505

485

470

450

430

410

390

375

MED

-

-

550

540

520

505

485

470

450

430

410

390

375

HIGH

-

-

-

-

-

-

555

540

525

510

490

475

460

WHISPER* 

M ODE

N/A

N/A

N/A

450

430

410

390

370

350

320

300

270

250

220

-

-

LOW

580

565

550

540

520

505

485

470

450

-

-

-

-

MED

640

620

610

595

580

565

555

540

525

510

490

475

460

MED

640

620

610

595

580

565

555

540

525

510

490

475

460

HIGH

-

-

675

670

655

650

640

620

610

595

580

565

550

WHISPER* 

M ODE

N/A

N/A

N/A

620

580

560

520

480

440

410

380

340

300

260

-

-

LOW

800

760

740

720

695

660

640

620

-

-

-

-

-

MED

880

860

840

820

800

780

750

720

700

670

650

625

600

MED

880

860

840

820

800

780

750

720

700

670

650

625

600

HIGH

-

-

-

-

895

880

860

820

805

795

780

770

760

WHISPER* 

M ODE

N/A

N/A

N/A

620

580

560

520

480

440

410

380

340

300

260

-

-

LOW

960

940

920

890

860

840

820

800

775

750

-

-

-

MED

1080

1060

1040

1010

990

970

950

930

900

880

860

840

820

MED

1080

1060

1040

1010

990

970

950

930

900

880

860

840

820

HIGH

-

-

-

-

1110

1090

1070

1060

1040

1020

990

980

960

WHISPER* 

M ODE

N/A

N/A

N/A

620

580

560

520

480

440

410

380

340

300

260

-

-

LOW

1120

1100

1090

1070

1050

1025

1010

990

970

940

920

-

-

MED

1230

1200

1185

1170

1150

1130

1110

1095

1080

1055

1040

1020

1000

MED

1230

1200

1185

1170

1150

1130

1110

1095

1080

1055

1040

1020

1000

HIGH

1320

1290

1275

1260

1240

1225

1205

1190

1175

1160

1140

1120

1100

100

LOW ESP

750

1010

HIGH ESP

120

LOW ESP

900

1200

HIGH ESP

060

LOW ESP

450

630

HIGH ESP

080

LOW ESP

600

820

HIGH ESP

040

LOW ESP

300

460

HIGH ESP

050

LOW ESP

375

530

HIGH ESP

020

LOW ESP

150

200

HIGH ESP

030

LOW ESP

220

350

HIGH ESP

External Static Pressure (in w .g.)

Model

EC Motor 

Speed

External 

Static 

Pressure 

Option

Min. 

SCFM

Rated 
SCFM

Note: All airflow ratings are taken at lowest voltage rating of dual rating (ie. 208 volt). 

Airflow ratings include resistance of dry coil, Return Air panel and clean MERV10 air filters.  

*Whisper mode during Fan On / Compressor Off mode for air circulation. Requires filed jumper of ‘R’ and ‘G1’ on terminal strip. See 

Figure 24 for wiring information. 

Table 18  

ECM Fan Data 

Summary of Contents for VSHP SERIES

Page 1: ...Manual IOM VERTICAL STACKED WATER SOURCE HEAT PUMPS MODEL VSHP DEV F DOCUMENT RELEASE OMEGA VSHP F IOM 1907 ISSUE DATE JULY 2019 3325A Orlando Dr Mississauga ON L4V 1C5 T 905 670 2269 F 905 670 3822...

Page 2: ...eason 7 Heating Season 7 Operating Limits 8 6 Chassis Installation 8 Installation of Fittings and Hoses 8 Units with NPSM Riser and Chassis Fittings 8 Units with NPT Riser and Chassis Fittings 8 Chass...

Page 3: ...Panel Dimensional Drawing 29 Figure 19 Perimeter Panel Cabinet Base Height Calculation 30 Figure 20 Perimeter R A Panel Furring Drawing Typ 2x2 Framing 31 Figure 21 Perimeter R A Panel Furring Drawing...

Page 4: ...ere and follow code could result in death of serious injury ALL FIELD WIRING MUST BE PER FORMED ONLY BY A QUALIFIED ELECTRICIAN All wiring must be in accord ance of with the manufacturer s specificati...

Page 5: ...d registers 2 CABINET DIMENSIONS Table 1 VSHP Cabinet Dimensions Silver Gold Series Figure 1 Silver Series Dimensional Drawing Model Cabinet Size Dimensions in W D C VSHP 020 X 16 18 5 14 VSHP 030 VSH...

Page 6: ...ns on same size piping Contractor to provide couplings where the piping is not swaged or for joining dissimilar piping sizes Use flexible duct connections to supply ducts and registers Power Wiring En...

Page 7: ...eld knockout supply air openings Front Back Side Top with 1 1 2 duct flange 3 Electrical box with advanced microprocessor 4 Removable direct drive blower motor assembly 5 Heat pump chassis 6 Chassis s...

Page 8: ...s Once discharge plenum is fastened to the underside of the concrete slab ship ping brackets must be removed See Figure 4 for com parison of Silver and Gold series cabinets Factory in stalled flexible...

Page 9: ...Do not rest or lean the unit on the risers Do not use the risers or stub outs to pick up the unit Only des ignated lift points should be used when moving or lifting cabinets Do not drop the risers 5...

Page 10: ...s to flow in the chassis water coil Damage to water components may occur Supply and return pipes must be interconnected at a minimum in the top and bottom units of each riser with factory supplied hos...

Page 11: ...t of the cabinet and tilt chassis so that the back aligns with the cabinet rails 3 Slide chassis into cabinet partially Check to ensure wiring harnesses are not being pinched Adjust the chas sis to en...

Page 12: ...intro duced during chassis installation ___Riser loop water is circulating through all units and at design conditions ___Unit condensate drain hose is securely attached to drain pan and condensate ris...

Page 13: ...f connecting thermostats with single speed control at the thermostat set DIP switch 6 to the OFF position In this mode thermostat can be connected to any of the G1 G2 and G3 terminals and a Run Fan re...

Page 14: ...all for compressor the low pressure switch is bypassed for the first 2 minutes of compressor operation to prevent nuisance low pressure start ups Timers and Interlocks Microprocessor board utilizes a...

Page 15: ...oard and to wireless router port 3 Open up your internet browser i e Explorer Google Chrome and type in the following address 192 168 0 99 Direct to Laptop Method 1 To connect to the controller you wi...

Page 16: ...ing unit operation information during faults or at start up as a troubleshooting aid For example in the figure below the first line item indicates Y terminal was ener gized Y 1 when the Cooling CLG 1...

Page 17: ...TENANCE 1 Check condensate flow to ensure adequate drainage and test for signs of impending blockages 2 Check that condensate alarm is operating correctly Alarm trips whenever water level rises above...

Page 18: ...re test If manual mode re test confirms proper water flow actuator is likely faulty Cooling Water too hot Reduce water loop temperature Heating Inadequate air flow Check blower Typical airflow should...

Page 19: ...missing or close shorted Latching alarm replace sensor CO Condensate Over flow Red Solid Condensate overflow alarm Hard Lock Out 2 Trips Red Blinking Condensate overflow alarm Soft Lock Out RST Refrig...

Page 20: ...Omega standard product built as free standing design The optional Gold series cabinet includes a factory built in canvas flex duct collar between the base chassis blower section and upper discharge pl...

Page 21: ...ft Hand LH RS Legend S Supply Riser C Condensate Riser R Return Riser Figure 5 Riser Handing Configurations Top View Table 9 VSHP Cabinet Riser Dimensions Notes As viewed from top risers can be order...

Page 22: ...required Riser Length Floor Clearance Height Slab Thickness 2 inch overlap Rounded up to 120 or 144 Omega supplies two standard riser lengths 120 10 and 144 12 to be field cut on site Omega does not s...

Page 23: ...ut Opening 4 3 Note Stub Outs Centered on Back Riser 6 6 Base Height Figure 7 Riser Stub Out Opening Detail Side View Note Back Rear Risers are centered to the cabinet Return Air Return Air Center ris...

Page 24: ...nnection w MNPSM Male Thread Figure 9 Hose Kit Details Table 10 Hose Kit Sizes Model Hose Kit Size in Length in VSHP 020 1 2 24 VSHP 030 1 2 24 VSHP 040 1 2 24 VSHP 050 1 2 24 VSHP 060 1 2 24 VSHP 080...

Page 25: ...upply Air Opening Sizes Return Air W W H H TOS Top Offset 3 Std 1 5 Min TOS F Front L Left T Top B Back R Right TOS 020 030 040 050 060 080 100 120 Horizontal 14 x 8 14 x 8 14 x 10 16 x 12 16 x 12 18...

Page 26: ...emote mounted ERV Figure 11 Optional Fresh Outside Air Duct Note Handing is referenced by facing the unit return air opening front OA Fresh Outside Air Intake The introduction of cold conditioned outs...

Page 27: ...ght Duct 3 Typ 3 Typ A B HORIZONTAL DISCHARGE VERTICAL DISCHARGE HBL Horiz Back Left Duct HBR Horiz Back Right Duct A B 3 Typ 3 Typ 3 Typ 3 Typ 3 Typ 3 Typ 2 Typ 2 Typ 2 Typ 2 Typ VBL Vert Back Left D...

Page 28: ...for enhanced sound attenuation Table 13 Acoustic Panel Sizes Figure 13 VHSP Acoustic Return Air Panel D C A 2 Mounting Holes x4 A B C D VSHP 020 VSHP 030 VSHP 040 VSHP 050 VSHP 060 VSHP 080 VSHP 100...

Page 29: ...clude flooring thickness underlayment and any concrete leveling as part of calculation Example If using a 5 baseboard with 1 Finished Flooring height and 0 5 gap B 5 1 0 5 1 5 B 5 Therefore a 5 Cabine...

Page 30: ...stical insulation for additional sound attenuation Figure 15 Acoustic Panel Furring Detail Typ 2x2 Framing Plan View 0 625 Min 2 Front of Cabinet to Front Drywall Typ 1 2 Drywall Nom 2x2 Studs Shown 1...

Page 31: ...n 1 increments C Flange Height Above Floor B 1 25 D Rough In Height Above Floor B 2 5 Table 14 Acoustic Panel Rough In Dimensions Y X W D X Y VSHP 020 VSHP 030 VSHP 040 VSHP 050 VSHP 060 VSHP 080 VSHP...

Page 32: ...er Panel Dimensional Drawing Table 15 Perimeter Panel Sizes D C A 2 B A B C D VSHP 020 VSHP 030 VSHP 040 VSHP 050 VSHP 060 VSHP 080 VSHP 100 VSHP 120 Model Cabinet Size Perimeter RA Panel Dimensions i...

Page 33: ...part of calculation Example If using a 5 baseboard with 1 Finished Flooring height and 0 5 gap B 5 1 0 5 0 5 B 7 Therefore a 7 Cabinet Base is required G BH B 0 5 Flooring Cabinet Base Concrete Slab B...

Page 34: ...units Seal RA perimeter with foam gasket tape or foil tape Insulate the drywall enclosure with plenum rated acoustical insulation for additional sound attenuation 2 Min 2 Front of Cabinet to Front Dry...

Page 35: ...1 increments C Flange Height Above Floor B 0 5 D Rough In Height Above Floor B 0 625 Table 16 Perimeter Panel Rough In Dimensions Y X W D X Y VSHP 020 VSHP 030 VSHP 040 VSHP 050 VSHP 060 VSHP 080 VSH...

Page 36: ...OMEGA WATER SOURCE HEAT PUMPS OMEGA VSHP F IOM 1907 33 www omega heatpump com Figure 23 VHSP Electrical Schematic PSC Fan Motor...

Page 37: ...OMEGA VSHP F IOM 1907 www omega heatpump com 34 Figure 24 VHSP Electrical Schematic ECM Fan...

Page 38: ...ntrance Low Voltage Control Wire Entrance G1 G2 R G3 Y O B C Notch For Optional Front Low Voltage Control Wire Entrance Optional ECM Fan w Whisper Mode Jumper R1 G1 Standard Fan Mode w Factory 6 wire...

Page 39: ...30 355 340 315 280 240 185 030 210 350 LOW 275 235 220 MED 310 275 250 230 HIGH 405 370 350 315 280 235 040 270 460 LOW 340 300 275 MED 410 370 350 338 315 HIGH 600 550 520 500 380 310 050 370 530 LOW...

Page 40: ...HIGH 675 670 655 650 640 620 610 595 580 565 550 WHISPER M ODE N A N A N A 620 580 560 520 480 440 410 380 340 300 260 LOW 800 760 740 720 695 660 640 620 MED 880 860 840 820 800 780 750 720 700 670 6...

Page 41: ...ncing valve see nameplate for GPM rating Air Temperature Measure the difference in temperature across air coil for measuring sensible capacity T LAT EAT Sensible Capacity Btuh T x CFM x 1 08 Entering...

Reviews: