Summary of Contents for Ti-400

Page 1: ...e m a i l i n f o o m e g a c o m F o r l a t e s t p r o d u c t m a n u a l s o m e g a c o m e n u s p d f m a n u a l s ...

Page 2: ...ia Turbine Paddlewheel Systems lia Totalizers Batch Controllers pH CONDUCTIVITY lia pH Electrodes Testers Accessories lia Benchtop Laboratory Meters lia Controllers Calibrators Simulators Pumps lia Industrial pH Conductivity Equipment DATA ACQUISITION lia Communications Based Acquisition Systems lia Data Logging Systems lia Wireless Sensors Transmitters Receivers lia Signal Conditioners Data Acqui...

Page 3: ...2 Main Menu 17 3 2 1 Isotherms 17 3 2 2 Measurement 18 3 2 3 Voice Note 18 3 2 4 System Setting 19 3 2 5 Files 19 3 2 6 SD Card 20 3 2 7 About this imager 20 3 3 Measurement Menu 21 3 3 1 Spot 21 3 3 2 Area 22 3 3 3 High and Low Temperature Capture 22 3 3 4 Emissivity 23 3 3 5 Commonly Used Materials 23 3 3 6 Lens Temperature Range 24 3 3 7 Temperature Alarm 24 3 4 Display Menu 25 3 4 1 Display Mo...

Page 4: ...amage will be caused to the thermal imager Caution Thermal imagers must transported inside original package No strong shaking or collision during the transportation and usage of thermal imager Caution The imager is recommended to keep inside original with environment of cool and dry ventilation without a strong electromagnetic Caution Keep any part of imagers from greasy dirt and any chemicals Ple...

Page 5: ...dew Repair evaluate remedial measures to ensure that the area is completely dry Others Iron and steel industry monitoring of steel rolling rolling process diagnosis of hot blast furnace damage annealing of plate temperature etc Fire extinguish forest fire prevention and potential fire source finding special material self ignition prevention electrical fire safety inspection Medical Body surface te...

Page 6: ...ssemble the product Laser beams can damage your eyes Please fix the product only through authorized technical service sites Warning In order to prevent personal injury Please only use the product for the specified purpose otherwise it may weaken the protection of the product Please replace the battery when indication of insufficient battery capacity otherwise the measurement may be incorrect Pleas...

Page 7: ...2Introduction of infrared thermal imager 2 1 Function Keys l EOMEG A 10 9 7 5 I 8 6 ...

Page 8: ...en seconds before turn on to ensure the safety of the thermal imager 2 Power on indicator Indicator is green after turn on 3 Charging indicator After the connection of the power adapter if the battery is installed correctly the red charging indicator lights up When the charging is complete the charging indicator will go out if the battery is not installed correctly the red charging indicator will ...

Page 9: ...the USB flash the imager contacted with the PC you can view files in the SD card by PC and the thermal imager can t take pictures About the machine you can see the relevant information about the thermal imager 5 6 7 8 Direction keys The arrow keys include up down and left and right referring to 5 6 7 8 respectively 9 F2 Measurement key Set the camera display mode palette flashlight and laser light...

Page 10: ...rea deletion and playback view etc Mode you can choose three modes the imager digital camera and picture in picture Palette can switch imager palette including the palette options iron red hot gray rainbow rain and grey red six palette Flashlight switch option controls the on and off of the thermal imager flashlight The laser light laser light switch option controls the on and off of the thermal i...

Page 11: ...2 2 Interfaces l EOMEG A 0 1 Jt ___ I 1 ...

Page 12: ...e which can be connected to the external headset for voice recording and playback 2 Video Video output 3 Power The external power input interface the power requirements of DC12V the center plug is positive 4 Micro USB 5 SD card slot l EOMEG A 5 ...

Page 13: ...1 1 Loading and Unloading of Battery The battery is in the handle of the instrument Push the battery cover at the bottom then unloading the battery When you loading the battery please note that one end of the battery contact should inserted firstly ...

Page 14: ...ed once of a period The interval is as follows Environmental temperature is 20 20 once every 6 months Environmental temperature is 20 45 once every 3 month Environmental temperature is 45 60 once every 1 months Each charge must be greater than 50 of the battery capacity The battery should be charged at 0 to 40 ambient temperature Under 0 will reduce the capacity of battery while the battery temper...

Page 15: ... have different functions Therefore all the signs in the interface are not necessarily displayed under various modes 3 1 4 Taking Picture After installing the battery press the thermal imager power switch greater than 3 seconds until the boot screen appears After about 50 seconds the instrument is initialized and entered the working state Open the lens cover aim at the target adjust the focus of t...

Page 16: ...F1 enter the playback view use the left and right arrow keys to view the picture When you have finished checking click the return key to return to the real time image of the thermal imager ll OMEGA Protot e Prot ot e Di rectory Names mm Numbe r Of F i I es 20 1 26 0 42 10 05 f 0 95 return Protot e DCit i11706 0 en 05095829 IR 1 26 2 42 10 06 f 0 95 Enter return ...

Page 17: ...de to built in memory to continue shooting the image Or remove the SD card insert it into the SD card reader and connect to the USB port of the PC machine You can view and export the stored images 3 2 Main Menu The main menu includes isotherm settings measurements voice notes system notes files SD cards and about imager 3 2 1 Isotherms Set the isotherms on and off the isothermal temperature and th...

Page 18: ...orrection and level span and other parameters 3 2 3 Voice Note Voice record and playback for better understand the images Ll OMEGA iiiiiuM g a Correct ion Leve I Span 42 10 08 S 0 95 Ent er return Protot1 e Start Recordin Voice Playback 42 10 07 S 0 95 Ent er return ...

Page 19: ...m language system and units and other parameters and can resume production settings 3 2 5 Files Select the appropriate folder and the number of files in that folder ll OMEGA iffiliPY Date Time Eng I I sh PAL Un1 t Save Current Settings Reset to default settings iffiGl Y Directory Names mmB f Jumber Of Fi Ies 20 42 10 08 S O 95 Enter return ...

Page 20: ... connect PC read SD card image or connect to the phone and take pictures by the phone 3 2 7 About this imager View the serial number and version number of the thermal imager Ll OMEGA 1 26 0 Bui Id in Memor USB Flash Memory 41 10 09 Z 0 95 Ent er x1 22 SlCSHSB1003 Fotric 326 L28 Ii oil 38 10 20 S 0 r s Enter L _ iffiiii4 1 ffiiiM S ...

Page 21: ... temperature range and temperature alarm switch etc 3 3 1 Spot Add the temperature measurement point the number of temperature measurement points vary according to the model Select the temperature points you can use the arrow keys to move the temperature measurement points ll OMEG Prot ot e Emissivity 95 General aterial Len Range Temperature Alarm 41 10 09 S O 95 Enter Prot ot e ...

Page 22: ...ture Capture Open the high and low temperature capture the image will appear Max and Min numerical points representing the highest temperature and minimum temperature values At the same time H and L are used to mark the position of the highest and lowest pixels in the picture ll OMEGA iDiGiP 5 1 a l 25 9 Box2 I Box3 Box4 BoxS 41 10 10 S 0 95 Enter return iDiGit Add Spot Add Box hot co Id On Em1ss1...

Page 23: ...commonly used materials list ll OMEGA iJ w idifoM S Add Spot ll dd Box hot cold On Emiss1 v1t 0 95 General aterial Len Range Temperature Alarm 41 10 11 S 0 95 Ent er Skin 0 98 Rubber 0 95 Copper Ox ide 0 78 Pa ints Wood o 90 Iron Red Rust 0 69 Stain less Steels Oxid ized 0 85 Concrete 0 92 Brick 0 94 41 10 12 S 0 95 ...

Page 24: ...and 200 650 lens have Len0 Len1 and Len2 options 3 3 7 Temperature Alarm There are three options for temperature alarm which are turn off high temperature alarm and low temperature alarm Ll OMEGA MGM lllll Temp Syal Is Lens 5 5mm L28 41 10 12 f O 95 Ent er Protot e Al arm Alarm Temp 25 ot J 26 3 41 10 12 f O t5 Ent er ...

Page 25: ...d playback view and other functions 3 4 1 Display Mode Three display modes thermal imager digital camera and picture in picture Below is the equipment in picture in picture display mode under which you can move the thermal image by arrow key Ll OMEGA Prot ot e Iron FI ash I i ght Off Laser Off Remove Al I View pictures ...

Page 26: ... off of the thermal imager laser 3 4 5 Clear The cleanup options include removing the temperature points lines isotherms and regions 3 4 6 Playback Enter the playback view option to view the captured image in the thermal imager Before viewing you need to select the folder you want to see in the main menu file LEOMEGJr Prot ot e DCitrll706 0 en 05095829 IR 1 22 6 37 10 14 f 95 Enter L ...

Page 27: ... the thermal imager mode press the display menu key F1 and then press the arrow keys up and down to adjust the infrared magnification As shown below the magnification of the image is 1 50 times magnification Adjust the infrared image edge in picture mode press the menu key F1 and then press the arrow keys up and down can adjust the infrared image part of the upper and lower edge xJ 22 Min 22 2 J 2...

Page 28: ... Thermal imager power off protection Wait 10 seconds to power on Automatic power off Battery runs out Change battery Automatic power off is turn on Turn off this function Battery consumption fast The environment temperature is too low Battery is not fully charged re charge the battery The life of battery runs out buy new battery Inactive thermal image The lens cover is not open Open the cover Free...

Page 29: ...idation 100 0 21 Wrought iron Dull 25 0 94 Polishing 38 0 28 Nickel Oxidation 200 0 37 Stainless steel Oxidation 60 0 85 Steel Oxidation under 800 200 0 79 Brick Surface 20 0 93 Concrete Surface 20 0 92 Glass Polishing and flat 20 0 94 Paint White 100 0 92 Black 100 0 97 Carbon Soot 25 0 95 Candle smoke 20 0 95 Graphite rough surface 20 0 98 Paint Average value of 16 colors 100 0 94 Paper White 20...

Page 30: ...ue Emissivity 0 96 Corrected temperature 0 C Background temperature close Analyze set parameter table Parameter Value Temperature alarm Off Threshold temperature 50 0 C Alarm temperature Not available Isothermal Off Isothermal temperature 50 0 C Isothermal span 1 0 C System settings parameter table Parameter Value Languish Chinese Automatic correction 60S LCD brightness 60 Shortcut key Laser Video...

Page 31: ...otherwise shall not exceed the purchase price of the component upon which liability is based In no event shall OMEGA be liable for consequential incidental or special damages CONDITIONS Equipment sold by OMEGA is not intended to be used nor shall it be used 1 as a Basic Component under 10 CFR 21 NRC used in or with any nuclear installation or activity or 2 in medical applications or used on humans...

Page 32: ...2 2378 USA Canada only Engineering Service 1 800 872 9436 USA Canada only Tel 203 359 1660 Fax 203 359 7700 e mail info omega com For Other Locations Visit omega com worldwide The infonnatioo contained in this document is believed to be correct but OMEGA accepts no liability for any errors it contains and re s erve s the right to alter specifications without notice ...