Specifications
4
4-5
Section 4 – Specifications cont’d.
Model IR-USB and IR-USB-HT Infrared Sensor
PC Interface: USB
USB Cable:
Integral to sensor, 2 m (6') shielded Type A
plug
Software (Included):
Requires Windows
®
XP, Vista (32bit or 64bit),
or Windows 7 (32bit or 64bit) operating system
Temperature Range:
-18 to 538°C (0 to 1000°F)
Accuracy @ 22°C (72°F) Ambient
Temperature and Emissivity of
0.95 or Greater:
±2% rdg or 2.2°C (4°F), whichever is greater
Optical Field of View:
6:1 (distance/spot size)
Repeatability:
±1% rdg
Spectral Response:
5 to 14 microns
Response Time:
100 ms (0 to 63% of final value)
Emissivity Range:
0.1 to 1.00, adjustable
Operating Temperature
Sensor Head:
0 to 70°C (32 to 158°F)
Sensor Head (-HT Model): 0 to 85°C (32 to 185°F)
Sensor Head with OS100-WC
(Water Cooling Jacket):
0 to 200°C (32 to 392°F)
Operating Relative Humidity: Less than 95% RH, non-condensing
Water Flow Rate (OS100-WC): 0.25 GPM, room temperature
Thermal Shock:
˜30 minutes for 25°C (77°F) abrupt ambient
temperature change
Warm-Up Period:
3 minutes
Air Flow Rate (OS100-AP):
1 CFM (0.5 L/s) (1 x 2.5")