File Menu
The Open menu item displays a dialog box which allows you to choose a data 

file to open and display on the graph and in the data log. This file must be a 

file that was saved by the Save menu item in TRH Central. If the file has been 

modified externally, you may not be able to open it.
The Save menu item displays a dialog box which allows you to save the data 

currently displayed on the graph and in the data log. The file format is (*.csv) 

(comma separated values), which can be opened by Microsoft Excel for further 

analysis and charting. It is strongly recommended that you do not modify this 

file, or you may not be able to open it again in USB-Temp. Use Excel’s “Save 

As” option to save it as a Microsoft Excel Workbook (*.xls), which you can then 

modify.
The Export Graph menu item displays a dialog box that allows you to either 

save an image of the current graph on the Graph Tab, or copy it to the clipboard.
The Print Preview menu item displays a standard Windows Print Preview 

dialog, allowing you to view the item(s) as they would be printed on a printer. 

You can also print from this dialog by clicking the printer icon in the upper left 

corner. If the Graph Tab is displayed before choosing this option, the current 

graph image will be previewed. If the Data Acquisition Tab is displayed, the 

data table in grid style format will be previewed.
The Print menu item displays a standard Windows Print dialog box. This allows 

you to select printers, printer preferences, page ranges, number of copies, etc. 

If you click the “Print” button, the specified page(s) will be sent to the printer. 

If you click the “Apply” button, you can then select the Print Preview menu to 

view your changes without printing.
The Exit menu option exits the TRH Central program.

View Menu
The Show Toolbar menu allows you to display an optional toolbar for file open, 

save, print, and graph positioning.
The Show Most Recently Used menu option displays the most recently used 

(opened/saved) filenames in the File menu.
The Clear Most Recently Used menu option removes all recently used filenames 

from the File menu.

Graph Menu
Graph Tools Cursor
Floating Cursor, when checked, will display a crosshair type cursor that you can 

move with the mouse. You can use the Floating Cursor to pinpoint a particular 

temperature and time. The status bar displays the data point number, the time, 

and the temperature, where the crosshairs meet.
Tracking Cursor, when checked, will perform similarly to the Floating Cursor, 

except that it will lock on to the plot line. With this option enabled, you 

can move the mouse left and right without regard to up and down, and the 

horizontal cursor will remain pointing to the plot line.

Software

3

3-14

Summary of Contents for RH-USB

Page 1: ...s Sensors Connectors and Pressure Transducers TM TJ USB Probe RH USB Probe IR USB UTC USB Connector PX409 USB e mail info omega com For latest product manuals www omegamanual info Shop online at omega...

Page 2: ...pecifications without notice omega com info omega com Servicing North America U S A Omega Engineering Inc Headquarters Toll Free 1 800 826 6342 USA Canada only Customer Service 1 800 622 2378 USA Cana...

Page 3: ...2 1 2 2 Included Items 2 1 2 3 IR USB Accessories 2 1 2 3 1 IR USB Accessories Dimensions 2 2 2 3 2 Laser Sighting Accessory Operation 2 4 Section 3 Software 3 1 3 1 Getting Started 3 1 3 2 Software...

Page 4: ...4 License Agreement Screen 3 3 3 5 Confirm Installation Screen 3 3 3 6 Welcome to the Device Driver Installation Wizard Screen 3 4 3 7 Device Driver Installation Wizard Screen 3 4 3 8 Completing the...

Page 5: ...our device Attempting to repair or service your unit may void your warranty 1 2 Safety Warnings and IEC Symbols This device is marked with international safety and hazard symbols in accordance with IE...

Page 6: ...teel Housing UTC USB Patented Universal Thermocouple Connector Converter with USB output PX409 USB Pressure Transducer with direct USB connection features a micro machined silicon sensor and 316L stai...

Page 7: ...BELOW HEX 0 87 AF 2 m 6 ft 22 4 0 88 7 6 0 3 7 6 0 3 7 6 0 3 104 1 4 1 104 1 4 1 119 4 4 7 GAGE VENT DIMENSIONS mm in PRESSURE RA OUTPUT SERIAL NO OM MODEL NO SU PX3 0 TO 5V 1234 PRESSURE RA OUTPUT SE...

Page 8: ...Figure 1 6 IR USB Dimensions Introduction 1 1 4 DIMENSIONS mm in 21 1 0 83 63 5 2 5 3 4 16 UNF 2A 25 4 1 0 25 4 1 0...

Page 9: ...r examining and removing contents save packing material and carton in the event reshipment is necessary 2 2 Included Items The following items are supplied in the box 1 TJ USB Probe Assembly or 1 RH U...

Page 10: ...B Figure 2 2 Water Cooling Jacket OS100 WC 23 3 919 19 0 755 4 0 156 31 8 1 25 90 3 2 1 8 12 7 0 5 12 7 0 5 50 0 1 97 3 2 1 8 25 4 1 42 9 1 69 Dimensions mm in Diameter INLET OUTLET 1 8 NPT COMPRESSIO...

Page 11: ...l Jacket Assembly Figure 2 4 Air Purge Collar OS100 AP Hardware 2 2 3 INLET OUTLET TO MAIN HOUSING UP TO 200C 392F AMBIENT TEMPERATURE 4 3 2 1 28 6 1 125 1 16 NPT COMPRESSION FITTING 3 4 16 UNF 2B THR...

Page 12: ...ensor head position so that the laser beam points to the center of the target area Turn off the battery pack and remove the laser sighting accessory from the sensor head See Fig 2 5 for reference You...

Page 13: ...LE SWITCH ON OFF BATTERY PACK POWER SUPPLY 50 8 2 0 19 75 38 1 1 5 Dimensions mm in OUTPUT 1 mW WAVELENGTH 630 670 nm CLASS II 2 LASER PRODUCT COMPLIES WITH FDA 21CFR 1040 10 EN60825 1 11 2001 LASER R...

Page 14: ...should meet the following minimum requirements Pentium Class or higher processor Hard Drive Space 30 meg Ram 256 meg 1 Available USB Port 1 CD ROM Drive Windows XP Vista 32bit or 64bit or Windows 7 3...

Page 15: ...ton Figure 3 2 Install Options Screen From this screen you select the folder were you want the program files installed on your PC The default setting will install the software under your Program folde...

Page 16: ...Next button The setup wizard will now install the software Figure 3 4 License Agreement Screen The setup wizard now has all the information to complete the installation of the software on your PC To...

Page 17: ...proper drivers To continue with installing the program click the Next button Figure 3 6 Welcome to the Device Driver Installation Wizard Screen Driver installation begins Figure 3 7 Device Driver Inst...

Page 18: ...the Finish button Figure 3 8 Completing the Device Driver Installation Wizard Screen Congratulations You have just successfully installed the TRH Central Program on your PC To end installing the progr...

Page 19: ...ed when you run the program This screen provides a real time digital reading of relative humidity when used with model RH USB or pressure in PSI when used with model PX409 USB or temperature when used...

Page 20: ...ur mouse on the Up and Down buttons to advance to a higher or lower setting The displayed temperature reading will change to RED digits and begin blinking to indicate that the process temperature has...

Page 21: ...between response time and reading stability Figure 3 13 Device Configuration Screen 3 5 Chart Tab The Chart tab allows you to start stop and view real time data from the transmitters in a screen plot...

Page 22: ...points have been collected in the continuous mode the oldest data point is shifted out on the left and the newest data point is added to the right Data will continue to be collected and displayed unt...

Page 23: ...The narrower the range between min and max the more detail can be seen on the chart Figure 3 16 Configure Axis Screen C or F Button The C or F button allows you to change the units of degrees displaye...

Page 24: ...be expanded as well and the data line s to allow viewing more detail You can close either of the axis scroll bars by clicking on the Red button of each scroll bar Pan Allows you to move the chart as...

Page 25: ...option is also available in the View Chart menu in the main menu bar Line Options Allows you to select which channel s you want to display and or change the color of each channel data line This allow...

Page 26: ...button will open the dialog box shown below This box allows you to select one or more channels to be plotted Click the checkbox next to the channel s number you want to include in your plot Figure 3...

Page 27: ...be previewed If the Data Acquisition Tab is displayed the data table in grid style format will be previewed The Print menu item displays a standard Windows Print dialog box This allows you to select...

Page 28: ...out while dragging toward the top zooms in If you have a wheel mouse you can zoom in out by clicking on the chart then use the wheel to zoom in out Configure The Configure Axes menu allows you to adj...

Page 29: ...uracy K1 1 C 1 8 F K2 3 C 5 4 F Resolution USB TC K1 0 1 USB TC K2 1 Stability USB TC K1 0 25 C USB TC K2 0 5 C Cold Junction Compensation Automatic 10 to 70 C Operating Environment 10 to 70 C 0 95 re...

Page 30: ...5 of reading or 1 0 C 1 8 F whichever is greater Type T E N 0 5 of reading or 2 0 C 3 6 F whichever is greater Type R S B C 0 5 of full scale Measurement Resolution 1 C Cold Junction Compensation Auto...

Page 31: ...ctrical termination Secondary Containment Vacuum and Pressure 10 inH2O to 5 psi to 1000 psi 15 to 1000 psi to 3000 psi 1500 to 5000 psi to 15 000 psi Secondary Containment Absolute Pressure 5 to 1000...

Page 32: ...2 to 98 RH Accuracy 3 RH 15 to 90 RH Repeatability 1 RH PC Interface USB USB Cable Integral to sensor 2 m 6 shielded Type A plug Software Included Requires Windows XP Vista 32bit or 64bit or Windows...

Page 33: ...is greater Optical Field of View 6 1 distance spot size Repeatability 1 rdg Spectral Response 5 to 14 microns Response Time 100 ms 0 to 63 of final value Emissivity Range 0 1 to 1 00 adjustable Opera...

Page 34: ...50 C 32 to 122 F Operating Relative Humidity Less than 95 RH non condensing Power Switch ON OFF Slide switch on the Battery Pack Power Indicator Red LED Power Battery Pack 3 Vdc Consists of two 1 5 Vd...

Page 35: ...iron 0 94 Iron and steel excluding stainless rusted iron plate 0 69 Iron and steel excluding stainless polished steel 0 07 Iron and steel excluding stainless polished steel oxidized at 600 C 1112 F 0...

Page 36: ...d soda 0 85 to 0 95 Marble polished light gray 0 93 Paints lacquers and varnishes Black matte shellac 0 91 Paints lacquers and varnishes aluminum paints 0 27 to 0 67 Paints lacquers and varnishes flat...

Page 37: ...NOTES USB Series Probes Sensors Connectors and Pressure Transducers 5 3...

Page 38: ...NOTES USB Series Probes Sensors Connectors and Pressure Transducers 5 4...

Page 39: ...A if the unit is found to be defective it will be repaired or replaced at no charge OMEGA s WARRANTY does not apply to defects resulting from any action of the purchaser including but not limited to m...

Page 40: ...s M U Turbine Paddlewheel Systems M U Totalizers Batch Controllers pH CONDUCTIVITY M U pH Electrodes Testers Accessories M U Benchtop Laboratory Meters M U Controllers Calibrators Simulators Pumps M U...

Reviews: