Display 

board

   Wire 

controller

Please adopt the shielded twisted-pair wire, 

and connect the shielded layed to (E)

To wire controller

The reserved wire control 

function is indicated in broken 

table, user can purchase the 

wire controller when necessary.

Fig. 7-4

Fig. 7-3

036 / 048

060

TO CCM 

COMM.BUS

TO INDOOR&OUTDOOR 

COMM.BUS

TO CCM 

COMM.BUS

TO INDOOR&OUTDOOR 

COMM.BUS

NOTE

The air conditioner should be grounded properly, otherwise it 

may affect the anti-interference of the whole unit.

7.6 Electrical Connection

Power supply

Main switch/fuse

 (can be purchased locally)

Power cable of indoor unit

IDU

Grounding

ODU

Grounding

Indoor and outdoor 

power cable

Power supply

 220-240V~ 50Hz

L    N   S

IDU

ODU

L(In)    N(In)   L(Out) N(Out) S(Out)

Incorrect wiring can cause some electrical components to 

malfunction.

Do not connect the cables with power on, which will 

endanger personal safety. 

CAUTION

NOTE

Remove the electric box cover of the outdoor unit (two screws).

Connect the cables of the indoor unit to the outdoor unit's 

terminal block according to the numbers.

To prevent water from entering, make an electrical coil with the 

connecting cable.

Wrap cables (conductors) that are not plugged into the terminal 

block with insulating tape so that they do not contact any 

electrical or metal parts.

■ Outdoor Unit

■ Cooling and heating type

Indoor and outdoor units are properly installed.
Piping length, and the amount of refrigerant charged have been 

recorded.
Piping and wiring are correct.
The voltage of the power supply is the same as the rated voltage 

of the air conditioner.
No leakage from the refrigerant piping system.
There is no obstacle at the air inlet and outlet of the IDUs and 

ODU.
Water discharge is smooth.
Open the check valves on the gas and liquid sides.
Heat insulation is complete.
Connect to the power supply to let the air conditioner warm up 

first.
Grounding cables have been properly connected.


10mm

40mm

Electric box cover

Connecting 

electrical cable

Terminal block of ODU

Wire clamp

L    N  S

7.5 Electrical Connection Diagram

      (For 

018 / 024

)

Fig. 7-5

Fig. 7-6

Summary of Contents for OTEC IEFC-D Series

Page 1: ...IEFC D Series Floor Ceiling Installation Manual...

Page 2: ...the set to fall water leakage electrical shock and fire Install at a strong and firm location which is able to withstand the set s weight If the strength is not enough or installation is not properly...

Page 3: ...radio waves a distance of 1 meter may not be sufficient enough to eliminate the noise The appliance is not intended for use by young children or infirm persons without supervision Don t install the a...

Page 4: ...T2 9x10 C H CAUTION 4 INDOOR UNIT INSTALLATION NOTE This manual is subject to changes due to technological improvement without further notices 4 1 The units may be mounted vertically provided that the...

Page 5: ...g arm on the hanging screw bolt Refer to Fig 4 11 Prepare the mounting bolts on the unit Refer to Fig 4 12 Screw nut Washer Hanging screw bolt Hanging arm Fig 4 11 20 25mm Fig 4 6 Fig 4 7 1 Fix the ho...

Page 6: ...hanging arm by sliding backward Securely tighten the mounting bolts on both sides Table 4 2 4 5 Material and size of the piping 5 1 The Procedure of Connecting Pipes 5 1 1 Measure the necessary length...

Page 7: ...ly flow 5 Be sure of no leakage by checking it with leak detector or soap water 6 Cover the joint of the connecting pipe to the indoor unit with the soundproof insulating sheath fittings and bind it w...

Page 8: ...Connect the indoor unit to power only after the refrigerant has been vacuumed 9 Don t connect the power wire to the signal wire connection end 7 1 The specification of power CAUTION A disconnection de...

Page 9: ...f the outdoor unit two screws Connect the cables of the indoor unit to the outdoor unit s terminal block according to the numbers To prevent water from entering make an electrical coil with the connec...

Page 10: ...e Check the following items according to the manual If there is any fault troubleshoot by referring to the section Fault and Troubleshooting in the manual Indoor Unit The wired remote controller switc...

Page 11: ...o restart function SW6 Definition SW7 Definition RESERVED RESERVED Unit state Display output Digital display panels Unit state Digital display Standby Shutting down Operation indicator flashes slowly...

Page 12: ...OMEGAIECS Round Flow Ceiling Cassette Technical Manual info otecvrf com www otecvrf com info omegavrf com www omegavrf com IECSJ3A IM1D0622...

Reviews: