background image

OMEGAnet

SM

 On-Line Service

http://www.omega.com

Internet e-mail

[email protected]

For immediate technical or application assistance:

USA and Canada:

Mexico and Latin America:

Sales Service: 1-800-826-6342 / 1-800-TC-OMEGA

SM

Tel: (95) 800-TC-OMEGA

SM

Customer Service: 1-800-622-2378 / 1-800-622-BEST

SM

FAX: (95) 203-359-7807

Engineering Service: 1-800-872-9436 / 1-800-USA-WHEN

SM

En Español: (203) 359-7803

TELEX: 996404  EASYLINK: 62968934  CABLE: OMEGA e-mail: [email protected]

Servicing North America:

USA:

 ISO 9001 Certified

Canada:

One Omega Drive, Box 4047

976 Bergar

Stamford, CT 06907-0047 Laval (Quebec) H7L5A1

Tel: (203) 359-1660

Tel: (514) 856-6928

FAX: (203)359-7700

FAX: (514) 856-6886

e-mail: [email protected] e-mail: [email protected]

Servicing Europe:

Benelux:

Postbus 8034, 1180 LA Amstelveen,

The Netherlands

Tel: (31) 20 6418405 FAX: (31) 20 6434643

Toll Free in Benelux: 06 0993344

e-mail: [email protected]

Czech Republic:

ul. Rude armady 1868, 733 01 Karvina-

Hranice, Czech Repubic

Tel: 420 (69) 6311627 FAX: 420 (69)

6311114

e-mail: [email protected]

France:

9, rue Denis Papin, 78190 Trappes

Tel: (33) 130-621-400 FAX: (33)130-699-120

Toll Free in France: 0800-4-06342

e-mail: [email protected]

Germany/Austria:

Daimlerstrasse 26, D-75392

Deckenpfronn, Germany

Tel: 49 (07056) 3017 FAX: 49 (07056) 8540

Toll Free in Germany: 0800 82 66342

e-mail: [email protected]

United Kingdom:

 

ISO 9002 Certified

One Omega Drive

Riverbend Technology Centre Northbank, Irlam,

Manchester, M44 5EX, England

Tel: 44 (161) 777-6611 FAX: 44 (161) 777-6622

Toll Free in England: 0800-488-488

e-mail: [email protected]

omega.com

TM

Summary of Contents for OS643W

Page 1: ...OMEGA OS643W Infrared Thermometer...

Page 2: ...info omega com e mail info omega com Servicing Europe Benelux Postbus 8034 1180 LA Amstelveen The Netherlands Tel 31 20 6418405 FAX 31 20 6434643 Toll Free in Benelux 06 0993344 e mail nl omega com Cz...

Page 3: ...sing MEAS button to extend battery life and with analog signal output function Temperature indication follows Reference Temperature Voltage Tables N I S T Monograph 175 Revised to ITS 90 for K type th...

Page 4: ...2 WARNING To avoid damage or burns do not make temperature measurement in microwave ovens The symbol on the instrument indicates that the operator must refer to an explanation in this manual...

Page 5: ...e errors Do not touch or hold by the front cone Temperature reading can be affected by heat from hand Do not place the meter on or around hot objects 70 C 158 F It may cause damage to the case If the...

Page 6: ...rement rate 2 5 times per second nominal Operating Environment 32 F to 122 F 0 C to 50 C at 70 relative humidity Storage Temperature 40 F to 140 F 20 C to 60 C 0 to 80 R H with battery removed from me...

Page 7: ...perating temperature Temperature Coefficient 0 2 of reading or 0 36 F 0 2 C whichever is greater change in accuracy per F C change in ambient operating tempera ture above 82 4 F 28 C or below 64 4 F 1...

Page 8: ...6 Spot size increases with distance from the probe tip as shown...

Page 9: ...r 0 3 rdg 2 F 58 F to 1999 F 0 3 rdg 1 C 50 C to 1000 C 0 5 rdg 1 C 1000 C to 1300 C Temperature Coefficient 0 1 times the applicable accuracy specification per C from 32 F to 64 F and 83 F to 122 F 0...

Page 10: ...MEASURE Button Depress MEAS button to turn on the meter for measuring temperature Releasing MEAS button to stop measuring temperature and automatically hold the display reading the meter turns off au...

Page 11: ...temperature is to be measured 6 Press the MEAS button Measurement is performed as long as the MEAS button is kept pressed 7 Referring to the spot size figure NOTE Although the field of measurement or...

Page 12: ...se switch to turn on or turn off the display Back Light 4 Use F C switch to select F or C the Temperature Range 5 Connect a type K thermocouple to the jack on the instrument Place the probe or thermoc...

Page 13: ...by solid matter With an emission thermometer which operates by detecting infrared radiation accurate measurement is possible irrespective of the air tempera ture or the measurement distance 3 Emissio...

Page 14: ...reflective object to 1 00 for a black body Factory set emissivity value of 0 95 which cover 90 of typical applications 5 If the surface to the measured is covered by frost or other material clean it...

Page 15: ...on the LCD display when replacement is needed To replace the batteries remove the screw from the back of the meter and lift off the battery cover case Remove the batteries from battery contacts Clean...

Page 16: ...der 0 96 Earth 0 92 to 0 96 Lacquer 0 80 to 0 95 Water 0 92 to 0 96 Lacquer matt 0 97 Ice 0 96 to 0 98 Rubber black 0 94 Snow 0 83 Plastic 0 85 to 0 95 Glass 0 90 to 0 95 Timber 0 90 Ceramic 0 90 to 0...

Page 17: ...use of its various products Nevertheless OMEGA only warrants that the parts manufactured by it will be as specified and free of defects OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND W...

Page 18: ...ondence The purchaser is responsible for shipping charges freight insurance and proper packaging to prevent breakage in transit FOR WARRANTY RETURNS please have the following information available BEF...

Page 19: ...onnectors Panels Assemblies Wire Thermocouple RTD Thermistor Calibrators Ice Point References Recorders Controllers Process Monitors Infrared Pyrometers ENVIRONMENTAL MONITORING AND CONTROL Metering C...

Reviews: