If your range hood does not function correctly when attempting any of the above, please ensure that your 

power is on and is functioning correctly. If the power seems to be functioning correctly in the house, there 

may be a problem with the range hood. Please call your authorized Omega service centre in this case to 

organize a service call. 

Lamp Replacement 

1. 

Switch the unit off and disconnect from mains power first. 

2. 

Remove filter and read labels regarding maximum lamp ratings. 

3. 

Press the light face and remove by turning in anti-clockwise 

direction. 

4. 

Pull out the LED lamp carefully and replace with the same type 

and same rated LED LAMP (240V 1.5W MAX). 

a.  ILCOS-D Code for the lamp is: DBR-1.5/65-H-64 

b.  Max Wattage: 2 x 1.5W 

 

Cleaning 

SAFETY PRECAUTION 

Before cleaning your rangehood or performing any maintenance, please ensure that the rangehood is 

turned off at the power point. 
Do not use abrasive cleaners to clean the rangehood. The use of warm soapy water and a cloth are 

recommended. 
Ensure that the rangehood is cleaned regularly, as a build-up of grease and fat may occur otherwise. 
The filters on the rangehood must be cleaned regularly to maintain efficiency, and prevent grease build up. 

The filter mesh is made of a high density Stainless Steel. It is recommended that this is undertaken every 4 

– 6 weeks, depending on frequency of use. The filters can be cleaned with warm soapy water or a cloth. 
Cleaning of the rangehood must be performed as described above; otherwise there is a possibility of a fire 

hazard due to grease and fat build up. 

Troubleshooting 

Fault 

Possible Cause 

Solution 

Light on, but motor 

does not work 

Fan switch turned off 

Select a fan switch position. 

Fan switch failed 

Contact Everdure Service. 

Motor failed 

Contact Everdure Service. 

Light does not work, 

motor does not work 

House fuses blown 

Reset/Replace fuses. 

Power cord loose or disconnected 

Refit cord to power outlet. 

Switch power outlet on. 

Oil leakage 

One-way valve and the air ventilation 

entrance are not tightly sealed 

Take down the one-way valve and seal with 

sealant. 

Leakage from the connection of U-shaped 

section and cover 

Take U-shaped section down and seal. 

Lights not working 

Broken/Faulty LED lamp 

Contact Everdure Service. 

Insufficient suction 

The distance between the rangehood and 

the gas top is too far 

Refit the rangehood to the correct distance. 

The Rangehood 

inclines 

The fixing screw not tight enough 

Tighten the hanging screw and make it 

horizontal. 

 

 