2. INSTALLATION

 

Please ensure that before installing the range hood all power has been switched off. 
Installation  must  be  in  accordance  to  the  local  electrical  authority  and  codes.  This 
range hood must be earthed at all times for the operators’ safety. 
The  power socket for  the  range  hood  should  be  positioned  to  enable  the  user  to  turn 
the power on and off easily (as there are no controls on the appliance) and to turn the 
appliance off to enable cleaning and any maintenance required. 
Ensure that when installing the range hood, that it is protected from any possible 
damage from tools etc. 
Ducting for this unit must be installed in accordance to the local authority.  Ensure that 
the fixings used for this range hood are suitable. 
Check  the  area  where  the  range  hood  is  to  be  fitted,  to  ensure  that  it  is 
structurally sound. 
Before using the appliance, remove the plastic coatings protecting  the stainless 
steel finish. 

 

Ensure that the wall is structurally sound, and is capable of carrying the weight 
of the range hood.

 

It is recommended that the dimension be checked on the range hood before 
installing.

 

 

1.  The cooker hood should be placed at a distance of 65-75cm from the 

cooking surface for the best effect. 

2.  Drill a hole in the cupboard, 490*265(mm) for model  ORU50PX. Make  sure 

the  distance  between  the edge of the hole and the edge of the cupboard 
edge is at least 35mm. Remove the filter. Remove the two halogen lights 
(twist anticlockwise), unscrew the two screws holding the lower facia panel 
and remove the lower fascia panel. 

3.  Fit the two flaps into the outlet (tabs facing upwards) creating the one way 

valve. 

4.  Fit the appliance into the 490*265mm hole, and fix into place using the 

supplied wood screws (8 positions). 

5.  Reattach the lower fascia panel using the two original 10mm screws. Refit 

the two halogen lights and attach the filter. 

6.  Connect the electrical plug to the power socket and test that the lights and 

fan operate when power is turned on. 

7.  Connect ducting (outlet is Ø150mm) to the outlet of the appliance. The 

ducting must remove the exhaust from the room. 

 

 

 

 

 