background image

 

Specifications 

OMG-USB-232-2

 

Page 

5

 

 

Technical Description 

The 

OMG-USB-232-2

 utilizes two USB UARTs. These chips feature 

programmable baud rate, data format, 128 byte Dual Port TX Buffer, and 384 byte 
Dual Port RX Buffer. The RS-232 transceiver supports data rates up to 460.8K 
baud. 

Features 

• 

Hot pluggable device that does not require opening the case 

• 

No system resources are required (i.e. I/O ports or IRQ’s) 

• 

LED status indicators for USB Enabled and port activity 

 

 
RS-232 

(DB-9 Male) 

Signal 

Name 

Pin # 

Mode 

GND 

Ground 

 

TX 

Transmit Data 

Output 

RTS 

Request To Send 

Output 

DTR 

Data Terminal Ready 

Output 

RX 

Receive Data 

Input 

CTS 

Clear To Send 

Input 

DSR 

Data Set Ready 

Input 

DCD 

Data Carrier Detect 

Input 

RI 

Ring Indicator 

Input 

 

Summary of Contents for OMG-USB-232-2

Page 1: ...www omega com e mail info omega com User sGuide OMG USB 232 2 Dual Port RS 232 to USB Adaptor Shop online at...

Page 2: ...court France TEL 33 0 1 61 37 29 00 FAX 33 0 1 30 57 54 27 Toll Free in France 0800 466 342 e mail sales omega fr Germany Austria Daimlerstrasse 26 D 75392 Deckenpfronn Germany TEL 49 0 7056 9398 0 FA...

Page 3: ...PECIFICATIONS 6 MANUFACTURING 6 POWER CONSUMPTION 6 MEAN TIME BETWEEN FAILURES MTBF 6 PHYSICAL DIMENSIONS 6 APPENDIX A TROUBLESHOOTING 7 APPENDIX B HOW TO GETASSISTANCE 8 APPENDIX C ELECTRICAL INTERFA...

Page 4: ...s that it does not require opening the computer case nor does it require resources such as I O ports or IRQ s It does require a system that supports USB both in terms of hardware and operating system...

Page 5: ...ther at the PC host or an upstream hub The OMG USB 232 2 is hot pluggable meaning there is no need to power down your computer prior to installation Connect the OMG USB 232 2 to an upstream host or hu...

Page 6: ...3 You can access your new COM ports by using the assigned COM identifiers as shown above In this case it is COM 3 4 However this assignment will vary from system to system At this point the hardware...

Page 7: ...S 232 interface Simply install the included software and connect the adapter to your USB port The device is immediately recognized by the system At that point connect the adapter to your target device...

Page 8: ...60 8K baud Features Hot pluggable device that does not require opening the case No system resources are required i e I O ports or IRQ s LED status indicators for USB Enabled and port activity RS 232 D...

Page 9: ...to UL 94V0 rating and are 100 electrically tested These printed circuit boards are solder m ask over bare copper or solder mask over tin nickel Power Consumption This device is a high power USB device...

Page 10: ...lled on the machine so that the necessary files are in place to complete the installation 3 When the OMG USB 232 2 is configured properly the USB Enabled LED E will be lit This should allow you to use...

Page 11: ...a computer ready to run diagnostics 3 Omega Engineering maintains a home page on the Internet Our home page address is www omega com The latest software updates and newest manuals are available via o...

Page 12: ...Terminal Equipment and Data Circuit Terminating Equipment Employing Serial Binary Data Interchange Both implementations are in wide spread use and will be referred to as RS 232 in this document RS 23...

Page 13: ...f a pre defined number of stop bits usually 1 1 5 or 2 An extra bit used for error detection is often appended before the stop bits Remain Idle or next start bit Odd Even or Unused STOP P BIT 5 to 8 D...

Page 14: ...e separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV t...

Page 15: ...022 Class B Limits and methods of measurement of radio interference characteristics of information technology equipment EN55024 Information technology equipment Immunity characteristics Limits and met...

Page 16: ...shall not exceed the purchase price of the component upon which liability is based In no event shall OMEGA be liable for consequential incidental or special damages CONDITIONS Equipment sold by OMEGA...

Page 17: ...city Indicators Turbine Paddlewheel Systems Totalizers Batch Controllers pH CONDUCTIVITY pH Electrodes Testers Accessories Benchtop Laboratory Meters Controllers Calibrators Simulators Pumps Industria...