background image

 

Appendix C - Electrical Interface 

OMG-USB-232-2

 

Page 

9

 

Appendix C - Electrical Interface 

 

RS-232 

Quite possibly the most widely used communication standard is RS-232. This 
implementation has been defined and revised several times and is often referred 
to as RS-232 or EIA/TIA-232. The IBM PC computer defined the RS-232 port on a 
9 pin D sub connector and subsequently the EIA/TIA approved this 
implementation as the EIA/TIA-574 standard. This standard is defined as the 

9-Position Non-Synchronous Interface between Data Terminal Equipment and 
Data Circuit-Terminating Equipment Employing Serial Binary Data 
Interchange

. Both implementations are in wide spread use and will be referred to 

as RS-232 in this document. RS-232 is capable of operating at data rates up to 20 
Kbps at distances less than 50 ft. The absolute maximum data rate may vary due 
to line conditions and cable lengths. RS-232 is a single ended or unbalanced 
interface, meaning that a single electrical signal is compared to a common signal 
(ground) to determine binary logic states.  The RS-232 and the EIA/TIA-574 
specification define two types of interface circuits, Data Terminal Equipment 
(DTE) and Data Circuit-Terminating Equipment (DCE). The OMG-USB-232-2 is a 
DTE device. 

 

Summary of Contents for OMG-USB-232-2

Page 1: ...www omega com e mail info omega com User sGuide OMG USB 232 2 Dual Port RS 232 to USB Adaptor Shop online at...

Page 2: ...court France TEL 33 0 1 61 37 29 00 FAX 33 0 1 30 57 54 27 Toll Free in France 0800 466 342 e mail sales omega fr Germany Austria Daimlerstrasse 26 D 75392 Deckenpfronn Germany TEL 49 0 7056 9398 0 FA...

Page 3: ...PECIFICATIONS 6 MANUFACTURING 6 POWER CONSUMPTION 6 MEAN TIME BETWEEN FAILURES MTBF 6 PHYSICAL DIMENSIONS 6 APPENDIX A TROUBLESHOOTING 7 APPENDIX B HOW TO GETASSISTANCE 8 APPENDIX C ELECTRICAL INTERFA...

Page 4: ...s that it does not require opening the computer case nor does it require resources such as I O ports or IRQ s It does require a system that supports USB both in terms of hardware and operating system...

Page 5: ...ther at the PC host or an upstream hub The OMG USB 232 2 is hot pluggable meaning there is no need to power down your computer prior to installation Connect the OMG USB 232 2 to an upstream host or hu...

Page 6: ...3 You can access your new COM ports by using the assigned COM identifiers as shown above In this case it is COM 3 4 However this assignment will vary from system to system At this point the hardware...

Page 7: ...S 232 interface Simply install the included software and connect the adapter to your USB port The device is immediately recognized by the system At that point connect the adapter to your target device...

Page 8: ...60 8K baud Features Hot pluggable device that does not require opening the case No system resources are required i e I O ports or IRQ s LED status indicators for USB Enabled and port activity RS 232 D...

Page 9: ...to UL 94V0 rating and are 100 electrically tested These printed circuit boards are solder m ask over bare copper or solder mask over tin nickel Power Consumption This device is a high power USB device...

Page 10: ...lled on the machine so that the necessary files are in place to complete the installation 3 When the OMG USB 232 2 is configured properly the USB Enabled LED E will be lit This should allow you to use...

Page 11: ...a computer ready to run diagnostics 3 Omega Engineering maintains a home page on the Internet Our home page address is www omega com The latest software updates and newest manuals are available via o...

Page 12: ...Terminal Equipment and Data Circuit Terminating Equipment Employing Serial Binary Data Interchange Both implementations are in wide spread use and will be referred to as RS 232 in this document RS 23...

Page 13: ...f a pre defined number of stop bits usually 1 1 5 or 2 An extra bit used for error detection is often appended before the stop bits Remain Idle or next start bit Odd Even or Unused STOP P BIT 5 to 8 D...

Page 14: ...e separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV t...

Page 15: ...022 Class B Limits and methods of measurement of radio interference characteristics of information technology equipment EN55024 Information technology equipment Immunity characteristics Limits and met...

Page 16: ...shall not exceed the purchase price of the component upon which liability is based In no event shall OMEGA be liable for consequential incidental or special damages CONDITIONS Equipment sold by OMEGA...

Page 17: ...city Indicators Turbine Paddlewheel Systems Totalizers Batch Controllers pH CONDUCTIVITY pH Electrodes Testers Accessories Benchtop Laboratory Meters Controllers Calibrators Simulators Pumps Industria...