![Omega OME-PCI-1002 User Manual Download Page 33](http://html1.mh-extra.com/html/omega/ome-pci-1002/ome-pci-1002_user-manual_4006654033.webp)
For OME-PCI-1002H:
[Bit1,Bit0]
[0 0]
[0 1]
[1 0]
[1 1]
Gain 1 10 100
1000
3.
These registers are set to 0 after power-on or a hardware reset signal.
3.2.2.8 The General Control Register
The general control register (18h) is used to control the add-on interrupt
source and the A/D trigger method. The format of this register is:
Bit4-2 Bit
1-0
Interrupt source
selection register
A/D trigger method
selection register
3.2.2.8.1 Interrupt Source Selection
There are four interrupt sources selectable for the OME-PCI-1002 (see
section 1.4.4).
[Bit4,Bit3,Bit2] Description
[ 0, 0, 0 ]
No interrupt source, disable all interrupts.
[ 0, 0, 1 ]
Interrupt after A/D conversion completes.
[ 0, 1, 0 ]
Interrupt after 8254 timer 0 falling.
[ 0, 1, 1 ]
Interrupt after external trigger falling.
[ 1, 0, 0 ]
Interrupt after 8254 timer 1 falling.
Others
No interrupt source, disable all interrupts.
Note: Bit 3-3 of general control register is set to 0 after a hardware reset.