Installation Guide

Installing the Interface cable

- OM-CP-IFC200
  Refer to the “Quick Start Guide” included in the package. 

Installing the software

Insert the Omega Software Flash Drive in an open USB port. If the autorun does not appear, locate the drive 
on the computer and double click on 

Autorun.exe

. Follow the instructions provided in the Installation Wizard.

Device Operation

Connecting and Starting the data logger

1.  Once the software is installed and running, plug the interface cable into the docking station. 
2.  Connect the USB end of the interface cable into an open USB port on the computer. Place the data logger 

into the docking station.

3.  The data logger will automatically appear under 

Connected Devices

 within the software.

4.  For most applications, select “

Custom Start

” from the menu bar and choose the desired start method, 

reading rate and other parameters appropriate for the data logging application and click “Start”. (

Quick 

Start

” applies the most recent custom start options, “

Batch Start

” is used for managing multiple loggers at 

once, “

Real Time Start

” stores the dataset as it records while connected to the logger.)

5.  The status of the device will change to “

Running

”, “

Waiting to Start

” or “

Waiting to Manual Start

”, 

depending upon your start method.

6.  Disconnect the data logger from the docking station and place it in the environment to measure. 

Note: The device will stop recording data when the end of memory is reached or the device is stopped. At this 
point the device cannot be restarted until it has been re-armed by the computer.

 

Downloading data from a data logger

1.  Connect the logger to the docking station.
2.  Highlight the data logger in the 

Connected Devices

 list. Click “

Stop

” on the menu bar.

3.  Once the data logger is stopped, with the logger highlighted, click “

Download

”. You will be prompted to 

name your report.

4.  Downloading will offload and save all the recorded data to the PC.

OM-CP-VOLT101A & OM-CP-VOLT101A-160MV

Summary of Contents for OM-CP-VOLT101A

Page 1: ...M0000 0016 INSTRUCTION SHEET Shop online at omega comSM e mail info omega com For latest product manuals www omegamanual info Xxxxx Xxxxxx Xxxxx Xxxxxx Xxxxxxxx M0000 0016 INSTRUCTION SHEET Shop onlin...

Page 2: ...15V and 30V models Single Ended Wiring OM CP VOLT101A 160MVDC Differential Wiring Two position removable screw terminal connections accepts 2 wire configurations Three position removable screw termina...

Page 3: ...be that the OM CP IFC200 is not properly connected 1 In the software click the File button then click Options 2 In the Options window click Communications 3 The Detected Interfaces box will list all...

Page 4: ...rs appropriate for the data logging application and click Start Quick Start applies the most recent custom start options Batch Start is used for managing multiple loggers at once Real Time Start store...

Page 5: ...inals and verify it is secure 4 Screw the enclosure back together securely Note Be sure not to over tighten the screws or strip the threads Recalibration The OM CP VOLT101A and OM CP VOLT101A 160MV st...

Page 6: ...FC200 Baud Rate 115 200 Typical Battery Life 10 years at a 15 minute reading rate Operating Environment 40 C to 80 C 40 F to 176 F 0 RH to 95 RH non condensing Enclosure Material ABS plastic Dimension...

Page 7: ...e VDC 160mVDC Measurement Resolution 5 V Calibrated Accuracy 0 01 FSR Memory 1 000 000 readings software configurable memory wrap 330 000 in enhanced start stop mode Reading Rate 4 readings very secon...

Page 8: ...a Basic Component under 10 CFR 21 NRC used in or with any nuclear installation or activity or 2 in medical applications or used on humans Should any Product s be used in or with any nuclear installat...

Reviews: