background image

Quick Start Manual

Troubleshooting Tips

Why is the wireless data logger not appearing in the software?

If the OM-CP-RFCURRENT2000A doesn’t appear in the Connected Devices panel, or an error message is  
received while using the OM-CP-RFCURRENT2000A, try the following: 

• Check that the OM-CP-RFC1000-EXT is properly connected. For more information, see Troubleshooting  

 

Interface Cable problems (below).

• Ensure that the battery is not discharged. For best voltage accuracy, use a voltage meter connected to the 

battery of the device. If possible, try switching the battery with a new OM-CP-BAT103. 

• Ensure that no other Omega software is running in the background.
• Ensure that 

Omega Software

 is being used.

• Ensure that the 

Connected Devices 

panel is large enough to display devices. This can be verified by  

positioning the cursor on the edge of the Connected Devices panel until the resize cursor appears, then 
dragging the edge of the panel to resize it. The screen layout may also be reset in the options menu by  
selecting 

File

Options

, and scrolling to the bottom.

Troubleshooting Interface Cable problems 

Check that the software properly recognizes the connected OM-CP-RFC1000-EXT wireless transceiver.

If the wireless data logger is not appearing in the 

Connected Devices

 list, it may be that the OM-CP-RFC1000-

EXT is not properly connected.

1.  

In the software, click the 

File

 button, then click 

Options

2.  

In the 

Options

 window, click 

Communications

3.  

The 

Detected Interfaces

 box will list all of the available communication interfaces. If the OM-CP-

   

RFC1000-EXT is listed here, then the software has correctly recognized and is ready to use it.

Check that Windows recognizes the connected OM-CP-RFC1000-EXT wireless transceiver.

If the software does not recognize the OM-CP-RFC1000-EXT, there may be a problem with Windows or the 
USB drivers.

1.  

In Windows, click 

Start

, right-click 

Computer

 and choose 

Properties

 or press 

Break

 as a 

 

keyboard shortcut. 

2.  

Click 

Device Manager

 in the left hand column.

3.  

Double click 

Universal Serial Bus Controllers

4.  

Look for an entry for

 Data logger Interface

.

5.

  

If the entry is present, and there are no warning messages or icons, then windows has correctly  

 

recognized the connected OM-CP-RFC1000-EXT. 

6.

  

If the entry is not present, or has an exclamation point icon next to it, the USB drivers may need to be 

 

installed. These are available on the software flash drive included with the OM-CP-RFC1000-EXT, and

   

on the Omega website.

Ensure that the USB end of the OM-CP-RFC1000-EXT is securely connected to the computer.
1.  

Locate the USB-A plug of the OM-CP-RFC1000-EXT. 

2.  

If the interface cable is connected to the PC, unplug it. Wait ten seconds. 

3.

  

Reconnect the cable to the PC.

4.

  

Check to make sure that the red LED is lit, indicating a successful connection.

Questions?

  For more details and instructions, please refer to the rest of this guide, visit us online at www.omega.com  

or contact us for support at 1 (800) 872-9436.

Summary of Contents for OM-CP-RFCURRENT2000A

Page 1: ...OM CP RFCURRENT2000A Wireless Current Data Logger...

Page 2: ...alone data logger or used with the OM CP RFC1000 EXT wireless transceiver to transmit data back to a central PC The OM CP RFCURRENT2000A transmits up to 500 line of sight to the OM CP RFC1000 EXT tran...

Page 3: ...data logger by clicking the Start icon 7 To download data select the device in the list click the Stop icon and then click the Download icon A graph will automatically display the data 1 Install the...

Page 4: ...fications will not be received if settings are incorrect 5 Click OK The OK button will be disabled if the Rule name box is empty Changing the Alarm Settings of a Device 1 In the Connected devices pane...

Page 5: ...on then click Options 2 In the Options window click Communications 3 The Detected Interfaces box will list all of the available communication interfaces If the OM CP RFC1000 EXT is listed here then th...

Page 6: ...4 Push the cover closed until it clicks Recalibration Standard recalibration for the OM CP RFCURRENT2000A 3A are two points 0A and 1 00A For the OM CP RFCURRENT2000A 20mA the standard calibration poin...

Page 7: ...ature CO2 flow rate and more Calibration Digital calibration through software Calibration Date Automatically recorded within device Battery Type Ultralife 9V lithium battery included user replaceable...

Page 8: ...line of sight unobstructed 500 max indoors typical urban environment Measurement Wireless Battery Warning WARNING MAY LEAK FLAME OR EXPLODE IF DISASSEMBLED SHORTED CHARGED CONNECTED TOGETHER MIXED WI...

Page 9: ...Quick Start Manual OM CP RFC1000 EXT Wireless Transceiver Other models available OM CP RFC1000 EUR Approved for European markets OM CP RFC1000 IP69K Splash Proof for harsh environments...

Page 10: ...85 C and a humidity range of 0 to 95 RH non condensing The OM CP RFC1000 EXT is rated IP40 and is protected against solids that are greater than 1mm in size This device is not water resistant LEDs Th...

Page 11: ...performance both the OM CP RFC1000 EXT and the Omega data loggers should be mounted in the same orientation This usually means that the external antenna should be pointing straight up The antenna can...

Page 12: ...r The images below show the orientations available of the switches for each channel Channel 26 all switches in the up position is not supported Follow the instructions below to configure the channel s...

Page 13: ...o wireless mode by holding down the Wireless button for 5 seconds Deploying and Activating Devices 1 Plug the OM CP RFC1000 EXT into the USB port on the base station computer Additional OM CP RFC1000...

Page 14: ...OM CP RFC1000 EXT is not properly connected 1 In the software click the File button then click Options 2 In the Options window click Communications 3 The Detected Interfaces box will list all of the a...

Page 15: ...als FCC ID OA3MRF24J40MC IC 7693A 24J40MC Transmission Distance To other OM CP RFC1000 EXTs 4000 max outdoor line of sight unobstructed 1000 max indoors typical urban environment Transmission Distance...

Page 16: ...ustrie Canada applicables aux appareils radio exempts de licence L exploitation est autoris e aux deux conditions suivantes 1 l appareil ne doit pas produire de brouillage et 2 l utilisateur de l appa...

Page 17: ...l application used on humans or misused in any way OMEGA assumes no responsibility as set forth in our basic WARRANTY DISCLAIMER language and additionally purchaser will indemnify OMEGA and hold OMEGA...

Reviews: