• Error codes:
Error code: Description:
Possible causes:
Error recovery:
C
The cooking zone can be
configured if a static “C” is
shown.
It’s not an error, the user is in
the service menu.
A suitably pan must be placed on the
relevant cooking zone.
C/-
The cooking zone will be
configured if a blinking “C”
is shown. After a successful
configuration the relevant
display shows “-”.
When the “-” is not displayed
please check the possible
causes of the E/5.
The user is in the service menu,
it’s not an error.
Wait for the sysmbol “-” or abort the
configuration activities by pressing the
selectkey and the “C” does not blink
anymore.
E
A blinking “E” on each cooking
zone indicates, that all configs
will be deleted.
The user is in the service menu,
it’s not an error.
Manual configuration.
E/2
Temperature limits are
excessed.
Electronik temperature to high. System must cool down.
E/3
Unsuitable pot.
Pot creates on the modul an
improper operating point
which can destroy devices,
e.g IGBT‘.
1. The error is automaticly cancelled
after 8s and the cooking zone can
be used again. In case of further
upcoming errors the pot have to be
changed.
E/4
Unconfigured induction
modul.
Induction modul is not
configured.
1. Delete the hob configuration and
activate the manual configuration.
2. Start the UI service menu to
configure the induction modul.
E/5
No communication between UI
and induction modul.
No power supply of induction
modul.
Contact the technical Service.
E/6
Main power disturbance.
1. Failure in main power
frequency detection.
2. Over voltage.
Contact the technical Service.
E/8
Fan failure.
Fan or control electronic is
defect.
Contact the technical Service.
E/9
Defect T sensor on inductor.
Sensor signal out of valid
range; sensor or electronic is
defect.
Contact the technical Service.
E/A
Hardware defect of induction
modul.
Defect hardware device
detected by the self check of
the modul.
Contact the technical Service.
E/C
Configuration failure.
2 cooking zones are dedicated
to the same element of the UI.
1. Erase the actual configuration
manual configuration with service
menu.
E/H
Fixed sensor value.
-
System must cool down.
- 11 -