Main Screen
The main screen summarises the current status of the machine
Current Air Cycle Status (1):
a) STAND-BY:
on status but motor off.
b) STATUS-OFF:
the motor is off and the load solenoid valve is disabled.
c) NO LOAD
:
the motor is on but the load solenoid valve is disabled.
d) LOADED:
the motor is on and the load solenoid valve is enabled.
e) REMOTE-OFF:
Remote program enabled in stand-by for the start-up remote command.
f) TIME-OFF:
Start-up program enabled, in stand-by for start time.
START-UP AND OPERATION
070°C
003°C
STATUS-OFF
08.5->10.0
09.0
BAR
STATUS-OFF
09.0BAR
08.5->10.0
100%
t <= 4°C
4< t <= 6°C
6< t <= 8°C
8< t <=10°C
t>10°C
AUT.
R.
R
P
16:18:33
14-03-13
!
AUT.
R.
R
P
!
Screw Temperature Panel
Dryer Status Panel
Current Time and Date Panel
Air Cycle Status Summary Panel
:
Current Pressure
:
Pressure range set
:
(functioning percentage indication)
:
Graphical representation of the motor without
inverter
:
Graphical representation of the motor with inverter
(indicazione percentual di funzionamento)
Machine Status Summary Panel
:If present, it indicates maintenance
is necessary on one or more
parts of the compressor
:If present, it indicates the
cooling fan is on
:If present, it indicates an alarm
is on
:If present, it indicates the remote
function is on
:If present, it indicates the
automatic start function is on
:If present, it indicates the dryer
function is on.
Negative when compressor dryer on
:If present, it indicates the
condensate drainage function is on.
Negative when the solenoid valve is on
:If present, it indicates functioning
with events programming
If activated, it indicates the dryer
temperature in two ways:
Graphic:
Text: indicates the temperature in
degrees