background image

Specifications subject to change      REV 05/04

How to Program the Features:
Step #1:

Turn off the ignition.

Step #2:

Press the valet switch 5 times, wait for audible response, and then select the feature by pressing the valet
button a number of times equal to the feature number.

Step #3:

Press the Lock or Unlock transmitter button to configure the feature as desired.

Step #4:

Repeat pressing the valet switch to access the next feature, and then again press the Lock or Unlock
button to configure the selected feature.

Smart Trigger:  The Smart Trigger utilizes the Domelight Supervision circuit for the alarm’s open door trigger input-
simply program the polarity with the Smart Trigger jumper.

Feature #28

Open Door Warning Upon Arming

OFF

ON

OFF

Feature #29

III Button Operates "Panic" or 3rd Channel Output

Panic

Panic       3rd Channel

Feature #30

Remote Start Run Time 10 or 20 Minutes

10 Minutes          20 Minutes     10 minutes

Feature #31

Steady / Flashing Lights During Remote Start

Steady

Steady

Flashing

Feature #32

Gasoline or Diesel Engine

Gasoline

Gasoline

Diesel

Feature #33

Extended Starter Cranking Time                                                                           Minimum- all 4 buttons used; 4 cranking times

Feature #34

“Tach Wire” or “Tachless “ Starter Operation

“Tachless”      “Tachless”    “Tach Wire”

Feature #35

Manual Transmission Remote Starting

OFF

ON

OFF

Feature #36

Turbo Timer

OFF

ON

OFF

Omega MAX-E

Wiring  Diagram  Overview

10 Amp

10 Amp

MAX-

E

Smart Trigger Port

Auxiliary Sensor Port #1

Auxiliary Sensor Port #2

Red/Black:
 Brake (+)

Satellite

Relay Ports

Doorlock Port

Yellow/Green:
Factory Disarm
Output
Yellow/Red:
Factory Arm
Output

Gray: (-) Trunk

Release  Output

Yellow

White

Green

Red/White   & Red

Black

Pink/Black: Start Activation (-)

White: (-) Arm Input

Programming Port

Blue/White:
 Safety Input (-)

P
R
N
D
L

Black/Yellow:
Tach Input

?

123

123

123

Brown: (-) Disarm Input

   

Pink: (-) 3rd  Channel Output

   (-) Door
Pin Switch

Hood /
Trunk
Switch

 Or
Pin

   

White: (+) Parking Light Output

   

Blue: (-) Instant

   

Violet: (+) Door

   

Green:

 (-) Door

   

Green/Violet: Dome

Light Output - connect to
vehicle’s dome light wire

Black/Red:

To (-) or (+) as needed

Status Light / Valet Switch

Holder Assembly

Status
Light &
Valet Switch may be
mounted separately

O

   Receiver
  Unit

Light

Switch

12345678901

12345678901

12345678901

12345678901

12345678901

12345678901

12345678901

12345678901

Parking Lights

   (+) Door
Pin Switch

    Yellow: 

 Ignition  Input/Output

Red/White:

 (+) 12 Volts

   

   White: 

Accessory Output

Red:

 (+) 12 Volts

Black: 

 (-) Ground

      White:
To Starter

Red: To
 Ignition
  Switch

Relay

   

Green: 

Starter Output

     Starter

Orange:

Armed (-) Output

AU-SOCKET
& relay for
starter interrupt

Battery

+

30 Amp

30 Amp

     Switch

Ignition

   

Brown: (+)

 Siren
    Red
        wire

Siren Black wire

to Ground

Siren

Siren Output