13
GETTING
AROUND
LVCN
‐
40
SERIES
Step
Eight
LVCN
‐
40
Series
features
a
6
‐
digit
display
with
relay
indicators
and
a
three
‐
button
user
interface.
The
indicator
displays
the
measured
value
and
relay
status
of
the
connected
sensor
(if
the
sensor
has
relays
and
they
are
configured
for
use).
Relay
1
‐
4
–
Indicates
when
the
sensor’s
relay
is
energized.
Note:
Not
all
LVCN
‐
414
series
sensor
models
have
relays.
o
If
the
sensor
does
not
have
any
relays,
then
the
indicators
will
remain
off.
6
‐
digit
Display
–
Shows
the
liquid
level
in
height
(inches,
cm,
feet
or
meters)
or
the
volume
of
liquid
(gallons
or
liters).
o
The
selection
of
height
vs.
volume
is
set
in
the
LVCN
‐
414
‐
SW
6.0
software.
Up
Button
–
Used
to
increase
a
set
point
value.
Select
Button
–
Used
to
enter
the
Menu
and
accept
values.
Down
Button
–
Used
to
decrease
a
set
point
value.
Note:
To
increase
the
scrolling
speed
of
the
display,
hold
down
the
SELECT
button
while
simultaneously
pressing
the
UP
or
DOWN
button.
Entering
the
MENU:
If
desired,
users
can
change
the
sensor’s
relay
ALARM,
VALVE
or
PUMP
ON
‐
OFF
set
points
using
LVCN
‐
40
Series.
To
enter
the
menu
LVCN
‐
40
Series
MENU
functions,
press
and
hold
the
SELECT
button
for
5
seconds.
The
MENU
will
then
scroll
between
the
configured
PUMP,
ALAMRS
and
RUN
modes.
Note:
If
the
relays
are
configured
for
PUMPS
and
ALARMS,
then
both
will
appear
in
the
menu.
If
the
relays
are
configured
for
Alarms
only,
then
PUMP
will
not
appear.
If
the
relays
are
configured
for
PUMPS
only
(also
for
valves),
then
ALARMS
will
not
appear.
To
change
a
pump
set
point
value,
press
SELECT
when
PUMP
appears.
To
change
an
Alarm
set
point
value,
press
SELECT
when
ALARMS
appear.
To
exit
the
menu
and
return
to
run
mode,
press
SELECT
when
RUN
appears.