background image

2

3.0   LCD DISPLAY SYMBOLS

On Target Indicator.  Blinks on whenever there is an input
signal.  Will appear to be solid on at higher frequencies.

Low Battery icon.  Indicates that the batteries are low and
need to be replaced.

Times Ten icon.  Indicates that the value shown is ten times
that which is displayed.

Laser Indicator.  Red laser is on when this indicator is
illuminated.

Lock icon.  Indicates that the unit is “Locked” on and making
continuous measurements (Lock mode).

Hand-held

21

10.0   MAKING MEASUREMENTS

10.1   Non-Contact Measurements

10.2   Direct Contact Measurements

Laser

 External Sensor (HHT20-ROS

shown)

OR

Light

WARNING:  Making measurements in direct contact with rotating
equipment can be dangerous.  Keep all loose clothing and hair
away from exposed moving machinery.  Keep the hand holding
the instrument well behind the back end of the Remote Contact
Assembly.  Properly replace all machinery guards after completing
measurement.  Do not use for rotation greater than 20,000 RPM.

to RCA

from HHT13

from HHT13

Rotational

Linear

(Use concave
tip for small
shafts)

ONLY USE MODERATE PRESSURE

Summary of Contents for HHT13

Page 1: ...sed on humans or misused in any way OMEGA assumes no responsibility as set forth in our basic WARRANTY DISCLAIMER language and additionally purchaser will indemnify OMEGA and hold OMEGA harmless from...

Page 2: ...tated This instrument is not user serviceable For technical assistance contact the sales organization from which you purchased the product In order to comply with EU Directive 2002 96 EC on Waste Elec...

Page 3: ...E Operation 14 8 0 TOTALizer Mode 15 8 1 TOTALizer Setup 15 8 2 TOTALizer Operation 18 9 0 TIMER Mode 19 9 1 TIMER Setup 19 9 2 TIMER Operation 20 10 0 MAKINGMEASUREMENTS 21 10 1 Non Contact Measureme...

Page 4: ...arrow LCD display Menu Select and Lock on button Battery compartment AVOID EXPOSURE LASER RADIATION IS EMITTED FROM THIS APERTURE Output socket Input socket Belt clip Tripod mounting bushing undersid...

Page 5: ...easurements Lock mode Hand held 21 10 0 MAKING MEASUREMENTS 10 1 Non Contact Measurements 10 2 Direct Contact Measurements Laser External Sensor HHT20 ROS shown OR Light WARNING Making measurements in...

Page 6: ...resolution limit Operating Range up to 25 feet 7 62 m or up to 70 degrees off perpendicular to reflective tape target Contact Specifications using optional Remote Contact Assembly Range Contact Tips...

Page 7: ...00 to 999 990 IPH Feet per Second 10 cm 0 003 to 109 36 FT S 12 in 0 009 to 200 00 FT S Feet per Minute 10 cm 0 164 to 6 561 7 FT M 12 in 0 500 to 12 000 FT M Feet per Hour 10 cm 9 843 to 393 700 FT...

Page 8: ...per Hour 10 cm 3 000 to 120 000 M H 12 in 9 144 to 219 460 M H TOTALIZER Counts 0 to 999 999 Scale Totals in Inches Feet Yards Centimeters or Meters Input Internal or External optics or linear contact...

Page 9: ...to be safe for indoor use under the following conditions per IEC61010 1 Installation Category II per IEC 664 Pollution Degree Level II per IEC 664 Temperature 40 F to 105 F 5 C to 40 C Humidity Maximu...

Page 10: ...For Small Shafts Select and install contact option 1 Contact Tip Convex tip shown Use Concave tip for small shafts Align flats 16 6 Enter selection of Units 7 Select Units 8 Save and advance Rotationa...

Page 11: ...with optional 12 inch wheel In S S S S S 15 1 Turn Power ON 2 Enter Setup Mode 3 Enter selection of Mode 4 Select TOTAL Mode 5 Save and advance OR Repeat until TOTAL displayed Last Mode selected is di...

Page 12: ...RPM or RPH Last Units selected are displayed Locked On Press and Hold 14 Unit will remember these settings including lock on off even if turned off and back on DONE USE CONTACT TIP or wheel selected...

Page 13: ...o measure 13 Rotational CRPS CRPM or CRPH Linear IPS IPM IPH FT S FT M FT H YPS YPM YPH MPH CM S CM M CM H M SEC M MIN M H NONE 1 2 or 3 OR Repeat until desired decimal places displayed OR Repeat unti...

Page 14: ...R 12 1 Turn Power ON 2 Enter Setup Mode 3 Enter selection of Mode 4 Select RATE Mode 5 Save and advance OR Toggles between RATE and TOTAL Select RATE Last Mode selected is displayed 1a To toggle Lock...

Reviews: