background image

Thank  you  for  your  selection  of 
this

 

Fruit Hardness Tester

.    

To

 

ensure

 

that

 

you

 

get

 

the

 

most

 

out

 

of

 

the

 

instrument

,

we

strongly  recommend  you  read  
and    follow  the  instructions  in 
this manual carefully.

 ALL RIGHTS RESERVED

!

*

held compact penetrometer for 

f r u i t  f i r m n e s s  a n d  s o m e 

vegetable hardness testing, the 

universally  accepted  measure 

of ripeness.

* The HFH80 series is the grower’s

indispensable tool for knowing 

when to pick and ship.

* The HFH80 Fruit Tester measures

the force required to push a 

   

   

     

The  Ripeness  Tester  is  a  hand-

FRUITS & VEGETABLES

MULTIPLE DISPLAY UNIT-KG, LB, N & Pa

EASY ZERO ADJUSTMENT.

ACCURACY VERIFICATION

Accurate Fruit Testing Requires:

Controlling tip penetration.

Providing  a  means  to  verify 

gage accuracy.

Controlling  the  speed  of  tip 

penetration.

1. FEATURES

General operation precautions

                      

WARNING

2.  A  GUIDE  TO  SELECT  THE 

MODEL

The model of HFH80 Fruit Testers

to  chose  from  3  models  is  used 

with  specific  size  penetrometer 

tips  for  testing  ripeness  of 

specific fruit.

HFH81

(3.5mm)  Small Fruits, Soft Fruits,

HFH83

(7.9mm)  Larger  Fruits,  Firm 

Fruits ,Hard Fruits

(11.1mm)  Apple, Firm Fruits

Small  Fruits:  e.g.  Strawberry, 

Cherry,  Grape , 

Berries

Soft Fruits:  e.g. Peach, Banana, 

A p r i c o t ,  P l u m , 

M e l o n ,  C i t r u s , 

Persimmon

Firm Fruits: e.g. Pear, Nectarine, Kiwi

Hard Fruits: e.g. Avocado

Display 4 digits,10 mm LCD

Range:  

HFH81

2

0.2-5.0 kgf/cm

Tip size 3.5mm

HFH83

2

0.2-11.0 kgf/cm  Tip size 11.1mm

2

0.4-22.0 kgf/cm  Tip size 7.9mm

Tip  size  can  be  interchanged 

after tip size is chosen. 

Resolution: 

0.01 if reading<10

0.1 if 10<reading<99.9

1 if reading>100

Unit conversion:

2

 kgf  (kgf/cm )

2

lbf (lbf/cm )

2

N (N/cm )

Pa

2

Accuracy:  ± (1%H+0.1)kgf/cm

Power supply: 4x1.5 AAA size

3. SPECIFICATIONS

3-1 Display

3-8 RS-232C interface

3-9 Battery compartment

3-2 Power key (Multifunctional)

3-3 Unit conversion

3-4 Tip selection (HFH80 only)

3-5 Max hold key

3-6 Zero 

3-7 Plunger tip

reading on the display should be 0. 

If  not,  depress  the  'ZERO'  key  to 

make the HFH80 tester display “0”.

E.  Hold  the  fruit  against  a  hard 

s u r f a c e  a n d  f o r c e  t h e  t i p 

vertically  into  the  pulp  at  a 

uniform  speed  (take  about  3 

seconds). 

F.  The  tip  should  consistently 

penetrate  to  the  break  in  tip 

diameter or to the scribed line on 

some tips.

G. Record reading on the display. 

H. If a maximum reading is needed, 

just press the key 'MAX' till the 

mark 'Max' shows on the display 

before taking measurements. 

The appearance of mark 'Max' is 

controlled by the key 'MAX'.

I.  To take the next measurement, just 

depress the 'ZERO' key and repeat 

steps from E to G. 

J. Unit conversion is controlled by 

depressing the key 'UNIT'.

K. For the model HFH83, make sure 

the plunger tip is in  accordance

5. MEASUREMENT PROCEDURES

Larger Fruits 

A. Select an appropriate plunger tip 

for  the  commodity  to  be  tested. 

See  “

A  GUIDE  TO  SELECT 

THE MODEL

”.

B. Select a random sample of 10 to 15 

fruits of uniform size and the same 

temperature or 3% of the lot to be 

sampled. For best results, suggest 

one person should test the lot.

C. R e m o v e   a   d i s c   o f   s k i n   o n

opposite  cheeks  of  the  fruit 

midway  between  the  stem  and 

bottom  on  sun  and  shade  sides. 

Then proceed with puncture test.

D. Zero adjustment

Hold the HFH80 vertically with the

plunger tip hanging in the air, the

plunger  tip  of  specified  size 

into  the  fruit  pulp.  The  force 

reading  assists  in  determining 

the appropriate picking time or 

monitoring  fruit  softening 

during storage.

*  Because  of  the  number  of  fruit 

a n d  v e g e t a b l e  v a r i e t i e s , 

geographical  locations  and 

o t h e r   v a r i a t i o n s ,   t h e  

a p p r o p r i a t e  f i r m n e s s  f o r 

harvesting will vary. Therefore 

HFH80 users must combine

 

 

experience  and  expertise  to 

establish  the  firmness  value 

that  applies  to  their  specific 

variety and locale.

*   Automatic power off to conserve

power.

*   Can communicate with PC for

r e c o r d i n g ,   p r i n t i n g   a n d  

analyzing  by  the  optional 

software  and  cable  for  RS232C 

interface.

Power off :  2 modes

Manual off at any time

Auto  power  off  after  5 

m i n u t e s  f r o m  l a s t  k e y 

operation

Operating conditions:

Temperature : 0-45

Humidity : below 90% RH

Dimensions: 

204x62x33mm or 

8.0x2.4x1.3 inch

Weight: 

230g   (not  including batteries)

Standard accessories  included :

    Carrying case ………………1 pc.

     Operation manual………… .1 pc.

Optional accessory:

Cable and software for 

R

P/N: HFH80-SW

S232C and USB

4. FRONT PANEL DESCRIPTIONS

3-5

3-4

3-3

3-2

3-6

3-8

3-1

3-7

3-9

HFH80 SERIES

Fruit Hardness Tester

M5080/0112

Shop online at: omega.com e-mail: [email protected]

Made in Taiwan

For latest product manuals: omegamanual.info

INSTRUCTION

SHEET

Reviews: