TROUBLESHOOTING

FPR300/310 SERIES INSTRUCTIONS

 

Page 9 

omega.com

Problem

Probable Cause

Things to Try...

No signal after installation

Insufficient flow

Consult Flow Rate Chart

Reduce pipe size or use different sensor

Bad connections to control 

electronics

Check connections at control:

Red (+), Black (-), White (signal)

Incompatible control

Use 6–36 Vdc power supply 

Add pull up resistor, if using current-sourcing 

device

Damaged or missing rotor

Remove flow sensor from fitting and check for free 

spinning; replace rotor

Failed magnetic sensor

Replace magnetic sensor

Inaccurate metering

Not enough straight pipe 

between meter and severe flow 

disturbance

Move meter away from flow disturbance or field 

calibrate

Wrong K-Factory entered

Check fitting for K-Factor, check indicator to  see if 

it is entered properly ("Set  K" on DPF143/144) 

Magnetic sensor failing to pick up 

each blade

Remove flow sensor from pipe. If indicator is 

DPF143/144, set K to 1.00, turn rotor slowly by 

hand, indicator should count each blade; replace 

sensor

Wrong time units on flow  

indicator

If using DPF143/144, check left side of display (sec, 

min, hr, day); change to desired unit

Summary of Contents for FPR310 Series

Page 1: ...e mail info omega com For latest product manuals www omegamanual info User sGuide Shop online at omega comSM FPR300 FPR310 FPR300 310 SERIES Low Flow Meter...

Page 2: ...ering Service 1 800 872 9436 USA Canada only Tel 203 359 1660 Fax 203 359 7700 e mail info omega com For Other Locations Visit omega com worldwide omega com info omega com The information contained in...

Page 3: ...Page 5 Installation Connections Piping Requirements Page 6 K Factor Page 6 Connections to Control Devices Page 6 Repair Rotor Replacement Page 7 Sensor Replacement Page 7 FPR300 310 Parts List Page 8...

Page 4: ...pes of controls including a full range of Omega rate displays and controls The Omega DPF 143 and DPF 144 provide flow rate and total flow indication The DPF 144 also includes 4 20 mA output capability...

Page 5: ...ring and ball Ruby ring and ball Cover Acrylic with clear lens polypropylene without clear lens optional PTFE Maximum Temperature 160 F 70 C 180 F 82 C Maximum Pressure 150 psi 10 bar 150 psi 10 bar A...

Page 6: ...cal 2 The sensor power supply can provide at least 2 mA 100 mA is typical 3 The sensor input on the PLC can accept a current sinking device 4 The PLC frequency response flow meter output frequency Inp...

Page 7: ...ing the cover The rotor can be easily dropped into the bottom bearing Starting the shaft into the upper bearing requires a bit of care It is easier if the rotor is spinning which can be done by lightl...

Page 8: ...Ceramic 6 magnet high res 100453 100453 PVDF Carbide 6 magnet high res 103932 n a PVDF Silicon Carbide 6 magnet high res 103934 103934 5 O Ring EPDM 100264 standard 100264 optional FKM 100219 optiona...

Page 9: ...nd check for free spinning replace rotor Failed magnetic sensor Replace magnetic sensor Inaccurate metering Not enough straight pipe between meter and severe flow disturbance Move meter away from flow...

Page 10: ...FPR300 310 SERIES INSTRUCTIONS Page 10 omega com...

Page 11: ...y OMEGA if the unit is found to be defective it will be repaired or replaced at no charge OMEGA s WARRANTY does not apply to defects resulting from any action of the purchaser including but not limite...

Page 12: ...locity Indicators M U Turbine Paddlewheel Systems M U Totalizers Batch Controllers pH CONDUCTIVITY M U pH Electrodes Testers Accessories M U Benchtop Laboratory Meters M U Controllers Calibrators Simu...

Reviews: