background image

REPAIR

FPR300/310 Parts List

2

1

8

3

4

5

3

6

7

FPR300

FPR310

1

Body

-038

100221

100269

-050

100222

100268

-075

100223

100267

-100

100224

100266

2

Flow direction Label

100256

100256

3

Bearing Assembly 

(includes 2)

103313

103313

Bearing Removal Tool 

(not shown)

100372

100372

4

Rotor with Shaft

PVDF/Ceramic 

(2 magnet)

103930

103930

PVDF/Carbide 

(2 magnet)

103931

n/a

PVDF/Silicon Carbide 

(2 magnet)

103933

103933

PVDF/Ceramic 

(6 magnet, high res)

100453

100453

PVDF/Carbide 

(6 magnet, high res)

103932

n/a

PVDF/Silicon Carbide 

(6 magnet, high res)

103934

103934

5

O- Ring

EPDM

100264 (standard)

100264 (optional)

FKM

100219 (optional)

100219 (optional)

PTFE-coated FKM

100973 (optional)

100973 (standard)

6

Cover 

(after 5/2005)

Polypro

100849

Not available

Acrylic

100848

Not available

PTFE

Not available

100847

7

Cover Screws 

(4 required)

Hexscrew

100310

Not applicable

Screw 

(requires hex nut 100025)

 

Not applicable

100022

Hex nut 

(requires screw 100022)

 

Not applicable

100025

8

Sensor

100419

100419

FPR300/310 SERIES INSTRUCTIONS

 

Page 8 

omega.com

Summary of Contents for FPR310 Series

Page 1: ...e mail info omega com For latest product manuals www omegamanual info User sGuide Shop online at omega comSM FPR300 FPR310 FPR300 310 SERIES Low Flow Meter...

Page 2: ...ering Service 1 800 872 9436 USA Canada only Tel 203 359 1660 Fax 203 359 7700 e mail info omega com For Other Locations Visit omega com worldwide omega com info omega com The information contained in...

Page 3: ...Page 5 Installation Connections Piping Requirements Page 6 K Factor Page 6 Connections to Control Devices Page 6 Repair Rotor Replacement Page 7 Sensor Replacement Page 7 FPR300 310 Parts List Page 8...

Page 4: ...pes of controls including a full range of Omega rate displays and controls The Omega DPF 143 and DPF 144 provide flow rate and total flow indication The DPF 144 also includes 4 20 mA output capability...

Page 5: ...ring and ball Ruby ring and ball Cover Acrylic with clear lens polypropylene without clear lens optional PTFE Maximum Temperature 160 F 70 C 180 F 82 C Maximum Pressure 150 psi 10 bar 150 psi 10 bar A...

Page 6: ...cal 2 The sensor power supply can provide at least 2 mA 100 mA is typical 3 The sensor input on the PLC can accept a current sinking device 4 The PLC frequency response flow meter output frequency Inp...

Page 7: ...ing the cover The rotor can be easily dropped into the bottom bearing Starting the shaft into the upper bearing requires a bit of care It is easier if the rotor is spinning which can be done by lightl...

Page 8: ...Ceramic 6 magnet high res 100453 100453 PVDF Carbide 6 magnet high res 103932 n a PVDF Silicon Carbide 6 magnet high res 103934 103934 5 O Ring EPDM 100264 standard 100264 optional FKM 100219 optiona...

Page 9: ...nd check for free spinning replace rotor Failed magnetic sensor Replace magnetic sensor Inaccurate metering Not enough straight pipe between meter and severe flow disturbance Move meter away from flow...

Page 10: ...FPR300 310 SERIES INSTRUCTIONS Page 10 omega com...

Page 11: ...y OMEGA if the unit is found to be defective it will be repaired or replaced at no charge OMEGA s WARRANTY does not apply to defects resulting from any action of the purchaser including but not limite...

Page 12: ...locity Indicators M U Turbine Paddlewheel Systems M U Totalizers Batch Controllers pH CONDUCTIVITY M U pH Electrodes Testers Accessories M U Benchtop Laboratory Meters M U Controllers Calibrators Simu...

Reviews: