background image

GENERAL INFORMATION

3/8”, 1/2”, 3/4”, 1”, Female NPT thread

(SAE optional)

18 feet standard (maximum cable run 2000 ft.)

TFE

PVDF (Kynar)

Zirconia ceramic (silicon carbide optional)

TFE-coated Viton (EPDM or Kalrez optional)

Ruby ring and ball

TFE

160˚ F (70˚ C)

150 PSI (10 bar)

+1% of full scale

5-24 Vdc, 2 mA min

Current sinking pulse, 6-24 Vdc

3/8”, 1/2”, 3/4”, 1”, Female NPT thread

(SAE optional)

18 feet standard (maximum cable run 2000 ft.)

Polypropylene

PVDF (Kynar)

Nickel tungsten carbide (zirconia ceramic optional)

EPDM (Kalrez or TFE-coated Viton optional)

Ruby ring and ball

Acrylic (Polypro optional)

160˚ F (70˚ C)

150 PSI (10 bar)

+1% of full scale

5-24 Vdc, 2 mA min

Current sinking pulse, 6-24 Vdc

Connection Ports

Sensor Cable

Materials    Body

 

  Rotor

 

  Shaft

 

  O-Ring

 

  Bearings

 

  Cover

Maximum Temperature

Maximum Pressure

Accuracy

Power

Outputs

FPR300

FPR310

SPECIFICATIONS

FEATURES

Thread-in Sensor, Field Replaceable,
6-24 Vdc pulse

18’ Sensor Cable

Standard Acrylic Top (FPR300)

Removable Lens Assembly

Hex Screws

Female NPT Threads (SAE optional)

These  versatile  impeller  flowmeters  are  available  in  3/8", 

1/2”,  3/4”,  and  1"  nominal  pipe  sizes  with  female  NPT 

threads (SAE optional).  They employ jewel bearings to allow 

for very low minimum flow rates and superior life.

With  a  body  material  of  polypropylene,  the 

FPR300

  is  an 

economical choice for metering water or low corrosion fluids. 

The lens cover is available in a choice of materials: acrylic 

for visual flow indication of low-corrosive fluids; polypropylene 

when more corrosion resistance is needed. The standard ro-

tor assembly is Kynar with tungsten carbide shaft (ceramic 

shaft optional).  The O-ring is EPDM.

The 

FPR310

 offers greater chemical resistance with a TFE 

body and cover, TFE-coated Viton O-ring, and standard Kynar/

ceramic rotor assembly (silicon carbide shaft optional).

The pulse output of these meters is compatible with many 

different types of controls, including a full range of Omega rate 

displays and controls.  The Omega DPF75-A provides flow rate 

and total flow indication, with 4-20 mA ouput capability. 

FPR300

shown

(Internal)
Jewel bearings
Kynar/Carbide or Kynar/Ceramic Rotor Assembly
EPDM (FPR300) or TFE-coated Viton (FPR310) O-ring

FLOW RANGE

 Model #

 

 *K-Factor 

    

Gal/Min 

   Liter/Min

 

 

 

   (Pulses/Gal)

 

 

   FPR300    FPR310 

 

FPR301/311

   1417    1394    0.07-5 

 0.27-18.9

 

FPR302/312

    658    634 

  0.1-10 

 0.38-37.9

 

FPR303/313

    468    476 

  0.2-20 

 0.75-75

 

FPR304/314

    254    250 

  0.5-40 

 1.9-150

*Nominal K-factors (based on averages) for standard 2-magnet FPR310 and 
FPR300. High resolution (6-magnet) K-factors are approximately tripled.

Summary of Contents for FPR300 Series

Page 1: ...FPR310 FPR300 FPR300 310 SERIES Low Flow Meter User sGuide Shop online at omega com email Info omega com For latest product manuals omegamanual Info...

Page 2: ...78280 Guyancourt France TEL 33 0 1 61 37 2900 FAX 33 0 1 30 57 5427 Toll Free in France 0800 466 342 e mail sales omega fr Germany Austria Daimlerstrasse 26 D 75392 Deckenpfronn Germany TEL 49 0 7056...

Page 3: ...bearings to allow for very low minimum flow rates and superior life With a body material of polypropylene the FPR300 is an economical choice for metering water or low corrosion fluids The lens cover i...

Page 4: ...ound Signal DC Voltage Ground Figure 1 Figure 2 Input Designed for Current Sinking NPN Devices Input Designed for Current Sourcing PNP Devices 2 2K Ohm Pull up Resistor NPN Device NPN Device INSTALLAT...

Page 5: ...e rotor disconnect the meter and remove the four screws that hold the cover in place Lift the cover and remove the rotor see parts diagram When putting in the new rotor be sure that the ends of the sh...

Page 6: ...29 11129 Kynar ceramic 6 magnet high res 11132 11132 Kynar cabide 6 magnet high res 11130 11130 5 O Ring EPDM 25081 TFE coated Viton 31403 6 Cover Before 5 05 After 5 05 Before 5 05 After 5 05 Polypro...

Page 7: ...otherwise shall not exceed the purchase price of the component upon which liability is based In no event shall OMEGA be liable for consequential incidental or special damages CONDITIONS Equipment sold...

Page 8: ...rbine Paddlewheel Systems Totalizers Batch Controllers pH CONDUCTIVITY pH Electrodes Testers Accessories Benchtop Laboratory Meters Controllers Calibrators Simulators Pumps Industrial pH Conductivity...

Reviews: