3-3
Table 1 Piping Requirements
Figure 1 shows the FMA1000 transmitter with fixed probe mount and right
angle mount.
Figure 2 shows the transmitter with a remote sensor probe connecting with 15
feet of flexible cable.
Figure 3 shows the transmitter’s general dimensions.
Figure 4 shows the mounting holes dimension for mounting of the transmitter
case on a wall.
Installation
3
Recommended
Straight Pipe
Length "A "
T ypical Piping
Remarks
Withou t
V anes
With
Va ne s
15D
15 D
C
losed Branch
A
A
A
A
A
A
A
A
20D
15 D
Elbow . Te e,
Branch Pipe
25D
15D
Elbow , 2 planes
25D
15 D
Long-radius
bend s
30D
25D
15D
15D
Elbow
Long-radius
bend s
40D
35D
15D
15D
Elbow
Long-radius
bend s
20D
15 D
C
ontracting Pip e
40D
20D
Expanding Pipe
Recommend Mete r
Be Installed
Upstream
Regulating,
reducing valves
Ball, check valves
Shut-of f valves
V
aried Section
Va
lves
Fittings in
Tw
o Planes
All Fittings in Same Plan
e
Note: Straight pipe length on the downstram side to be 5 pipe diameters minimum .
Note: D – Pipe internal diameter
.