background image

CLEANING  AND  DISAS SEMBLY 

Occasional cleanin:s may be required if dirt appears in 

the flow tube or if float movement becomes restricted. 
To clean,  remove lhe  top  plug  and  remove  the  float. 

Wash the tapered hole and top plug with a mild liquid 
detergent and  soft  brush.  Rinse  all  parts  with  clean 
water  and  dry  thoroughly  with  clean  air or  nitrogen. 

Do not  use solvents  to clean  this  meter 

as they will 

attack the acrylic and destroy the meter. 

FL-2001 

FL-203I 

FL-2060 

DIMENS IONS 

to 

to 

to 

FL-202S 

FL-20S7 

FL-2069 

IN. 

6½ 

6 5/8 

mm 

102 

165 

164 

IN. 

1/1 

5 1/2 

mm 

76.2 

140 

140 

IN. 

I  3/8 

I  1/8 

mm 

25.1 

34.9 

28.6 

IN. 

I  5/8 

3½ 

3 1/, 

mm 

41.3 

88.9 

38.1 

IN. 

I  3/16 

I  !/2 

11/2 

mm 

30.2 

38.1 

38.1 

IN. 

I  1/8 

I  1/8 

I  3/8 

mm 

:!9.6 

28.6 

34.9 

IN. 

1/8-27 

1/8-27 

1/4-18 

mm 

MNPT 

MNPT 

MNPT 

*Does not include l /8" backplate. 

FL-2001 to FL-202S FLOW RATES 

RANGE 

MODEL 

RANGE 

MODEL 

SCFHOF AIR 

CODE 

LPM OF AIR 

CODE 

1-1 

FL-2001 

04-5 

FL-2010 

2-2 

l'L-2002 

1-1 

FL-2011 

4-5 

FL-2003 

2-2 5 

FL-2012 

5-10 

FL-2004 

4-5 

FL-2013 

2-20 

FL-2005 

1-10 

FL-2014 

3.-30 

FL-2006 

2-25 

FL-2015 

4-50 

FL-2007 

4-50 

FL-2016 

10-100 

FL-2008 

10-100 

FL-2017 

20-200 

.� 

GPHOFWATER 

CODE 

CCM OFWATER 

CODE 

2-2 

FL-2021 

5-50 

FL-2018 

.4-5 

FL-2022 

10-100 

FL-2019 

1-10 

FL-2023 

20-240 

FL-2020 

2-20 

FL-2024 

4-40 

FL-2025 

RE-AS SEMBLY 

Check to  make sure that  all  parts are clean and dry. 

To  lubricate  the  o-rings,  apply  a  small  amount  of 

halocarbon grease prior to re-assembly. If applicable, 

reinstall  the  rod  guide  assembly  into  the  flowmeter 
body.  Make sure the rod guide is seated firmly in the 
body of the meter. Reinstall the top plug, making sure 
that  the  rod  guide  is  properly  aligned.  Tighten  top 
plug  until  it's  flush  with  top  of  acrylic  body. 
Exceeding this may damage the meter body. 
If you have any questions regarding  the  installation, 

maintenance or use of this  flowmeter,  please call  the 

Customer Service Department. 

-. 

10-32MEADED 

INSERTS (2Pt..ACES) 

<:f 

__ _l 

- F  ---! 

_,,,_____J 

�-c�i 

FL-2060 to FL-2069 FLOW  RA TES* 

RANGE 

MODEL 

RANGE 

SCFM OF AIR 

CODE 

LPM OF AIR 

5-5 

FL-2060 

14-140 

1-10 

FL-2061 

30-280 

2-20 

FL-2062 

60-560 

GPM OFWATE R 

CODE 

LPM OFWATER 

2-2.5 

FL-2066 

8-9 

4-5 

F L -2067 

1.5-20 

FL-203 I to FL-20S7 FLOW  RA TES 

RANGE 

MODEL 

RANGE 

SCFHOF AIR 

CODE 

CCM OFWATER 

.4-5 

FL-2031 

4-50 

1-10 

FL-2032 

10-120 

2-20 

FL-2033 

25-225 

4-40 

FL-2034 

40-400 

10-100 

FL-2035 

40-u60 

14-150 

FL-2036 

100-1500 

20-200 

FL-2037 

200-3000 

CCM OF AIR 

CODE 

300-3700 

100-1000 

FL-2038 

GPHWATER 

LPM OF AIR 

CODE 

1-10 

4-5 

FL-2039 

2-25 

1-10 

FL-2040 

4-50 

2-20 

FL-2041 

6-60 

3-30 

FL-2042 

SCFM OF AIR 

4-50 

FL-2043 

.3-3 

10-100 

FL-2044 

MODEL 

CODE 

FL-2063 

FL-2064 
FL-2065 

CODE 

FL-2068 

FL-2069 

MODEL 

CODE 

FL-2045 
FL-2046 

FL-2047 
FL-2048 

FL-2049 
FL-2050 
FL-2051 
FL-2052 

CODE 

FL-2053 
FL-2054 
FL-2055 

FL-2056 

CODE 

FL-2057 

CONTINUED PRODUCT IMPROVEMENT MAY RESULT IN SPECIFICATION REVISIONS 

WHEN ORDERING PARTS PLEASE tNCLUDE PART DESCRlPTION, ITEM NUMBER AND lYPE OF MATERIAL REQUIRED. 

M-3231 /0505 