ECD 15B / 40B / 90B / 150B - Installation and operating manual
2
Technical data
Please take the relevant climate zone into account when dimensioning yours specific ECD
series application.
Northern Europe, Canada, Northern USA, Central Asia
Central and Southern Europe, Central America
South East Asian coastal regions, Oceania, Amazon and Congo regions
Type
ECD 15B
ECD 40B
ECD 90B
ECD 150B
Voltage
115 VAC
115 V +/-10%
230 VAC
230 V +/-10%
Power
115 VAC
24 VA
230 VAC
24 VA
Frequency
50 – 60 Hz
Operation pressure range
0 – 16 bar / 0 – 232 psi
Drain capacity (7 bar / 101
psi)
15 l/h
0,0088 scfm
40 l/h
0,0235 scfm
90 l/h
0,0529 scfm
150 l/h
0,0882 scfm
Operating temperature
range
1,5 – 65°C
1,5 – 65°C
1,5 – 65°C
1,5 – 65°C
Inlet connection
G 1/2"
G 1/2"
G 1/2"
G 1/2"
Outlet connection
G 1/8"
G 1/8"
G 1/8"
G 1/8"
Power interface
3 x 0,75mm
2
3 x 0,75mm
2
3 x 0,75mm
2
3 x 0,75mm
2
Protection class
IP54
IP54
IP54
IP54
Volume
0,15 l
0,15 l
0,2 l
0,28 l
Mass
0,9 kg
0,9 kg
1,05 kg
1,15
Dimensions A x B x C [mm]
120 x 82 x 125
120 x 82 x 125
120 x 82 x 135
120 x 82 x 150
Peak Compressor
Performance
[m
3
/min]
11,6
29,4
60,6
111,6
9,3
23,5
48,5
89,3
5,8
14,7
30,3
55,8
Peak Dryer
Performance
[m
3
/min]
23,2
58,8
121,2
223,2
18,6
47,0
97,0
178,6
11,6
29,4
60,6
111,6
Peak Filter
Performance
[m
3
/min]
116
294
606
1116
93
235
485
893
58
147
303
558
Compressor power [kW]
Up to 30
Up to 75
Up to 160
Up to 315