background image

OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible. This affords 

our customers the latest in technology and engineering.
OMEGA is a trademark of OMEGA ENGINEERING, INC.
© Copyright 2017 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied, 

reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without the 

prior written consent of OMEGA ENGINEERING, INC.

FOR 

WARRANTY

 RETURNS, please have the 

following information available BEFORE  

contacting OMEGA:
1.  Purchase Order number under which the product

was PURCHASED,

2.  Model and serial number of the product under

warranty, and

3. Repair instructions and/or specific problems

relative to the product.

FOR 

NON-WARRANTY

 REPAIRS, consult OMEGA 

for current repair charges. Have the following 

information available BEFORE contacting OMEGA:
1.  Purchase  Order  number  to  cover  the  COST 

of the repair,

2. Model and serial number of the product, and
3. Repair instructions and/or specific problems

relative to the product.

WARRANTY/DISCLAIMER

OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a 

period of 

61

 months

 from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month 

grace period to the normal 

five

 (

5

) year product warranty

 to cover handling and shipping time. This 

ensures that OMEGA’s customers receive maximum coverage on each product. 
If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA’s Customer Service 

Department will issue an Authorized Return (AR) number immediately upon phone or written request. 

Upon examination by OMEGA, if the unit is found to be defective, it will be repaired or replaced at no 

charge. OMEGA’s WARRANTY does not apply to defects resulting from any action of the purchaser, 

including but not limited to mishandling, improper interfacing, operation outside of design limits,  

improper repair, or unauthorized modification. This WARRANTY is VOID if the unit shows evidence of  

having been tampered with or shows evidence of having been damaged as a result of excessive corrosion; 

or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating 

conditions outside of OMEGA’s control. Components in which wear is not warranted, include but are not  

limited to contact points, fuses, and triacs.

OMEGA is pleased to offer suggestions on the use of its various products. However,  

OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for 

any damages that result from the use of its products in accordance with information provided 

by OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by the 

company will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR  

REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF 

TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY 

AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF  

LIABILITY: The remedies of purchaser set forth herein are exclusive, and the total liability of  

OMEGA with respect to this order, whether based on contract, warranty, negligence,  

indemnification, strict liability or otherwise, shall not exceed the purchase price of the  

component upon which liability is based. In no event shall OMEGA be liable for  

consequential, incidental or special damages.

CONDITIONS:  Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a “Basic 

Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical 

applications or used on humans. Should any Product(s) be used in or with any nuclear installation or 

activity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibility 

as set forth in our basic WARRANTY/DISCLAIMER language, and, additionally, purchaser will indemnify 

OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the 

Product(s) in such a manner.

RETURN REQUESTS/INQUIRIES

Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. 

BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED 

RETURN (AR) NUMBER FROM OMEGA’S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID 

PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return 

package and on any correspondence.
The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent 

breakage in transit. 

 

MQS5541_1017

Summary of Contents for CS8DPT

Page 1: ...ervice 1 800 622 2378 USA Canada only Engineering Service 1 800 872 9436 USA Canada only Tel 203 359 1660 Fax 203 359 7700 e mail info omega com For Other Locations Visit omega com worldwide The infor...

Page 2: ...RATION AND PROGRAMMING 9 4 1 PLATINUM Series Navigation 9 4 2 Selecting an Input INIt INPt 10 4 3 Set the Setpoint 1 Value PRoG SP1 10 4 4 Set up the Control Output 11 4 4 1 Select an Output Channel P...

Page 3: ...onal safety and hazard symbols shown in the table below in accordance with 2014 35 EU Low Voltage Directive It is important to read and follow all precautions and instructions in this manual before op...

Page 4: ...the packing list it is important to verify all equipment shipped has been delivered as shown in Figure 1 and Table 1 If there are any questions about the shipment please email or call the Customer Se...

Page 5: ...Power Cord DM 230V 16A USA Canada Mexico Power Cord Molded 120V Italy Power Cord IT 230V 16A Continental Europe Power Cord E 10A 240V 10A Europe Power Cord E 16A 240V 16A 3 HARDWARE SETUP This section...

Page 6: ...l communications transmit Table 5 summarizes the universal input pin assignments for different sensor inputs All sensor selections are firmware controlled and no jumper settings are required when swit...

Page 7: ...rs R1 and R2 included in the provided Wire Kit across terminals 4 and 6 and terminals 1 and 8 respectively This allows the Bridge voltage to be measured When powering a bridge from the unit use an int...

Page 8: ...s Output 2 3 Ethernet Port RJ45 10 100Base T Optional 4 AC Main Input Plug IEC60320 C13 Power Socket 90 to 240 Vac 50 60 Hz 5 Output 1 Relay Output 90 240 VAC 3A Max 6 Output 2 SSR Output 90 240 VAC 5...

Page 9: ...es across a set of menu choices at a given level When changing numerical settings press the LEFT button to make the next digit one digit to the left active The RIGHT button moves across a set of menu...

Page 10: ...all process ranges MANL Rd 1 ____ Low display reading IN 1 ____ Manual input for Rd 1 Rd 2 ____ High display reading IN 2 ____ Manual input for Rd 2 LIVE Rd 1 ____ Low display reading IN 1 ____ Live R...

Page 11: ...ng Parameters oFF Turn off the output channel factory default PId Set the output to Proportional Integral Derivative PID Control oN oF Set the output to On Off Control Mode RtRN Set up the output for...

Page 12: ...tion ACtN parameter PRoG PID S ACtn as detailed below Setting Description RVRS Reverse Output increases the process value dRCt Direct Output decreases the process value 5 Set the Autotune Timeout A to...

Page 13: ...10 Volts factory default 0 5 0 to 5 Volts 0 20 0 to 20 mA 4 20 4 to 20 mA 0 24 0 to 24 mA 4 7 2 Set Mode to Retransmission Enable the output by setting the mode to Retransmission PRoG IAN 1 Mode RtRN...

Page 14: ...r electrical equipment for measurement control and laboratory EMC Measurement Category I Category I includes measurements performed on circuits not directly connected to the Mains Supply power Maximum...

Page 15: ...er calibration is available with adjustable gain and offset as well as ice point calibration Refer to the Platinum Series User s Manual M5451 for additional information on user calibration options Opt...

Page 16: ...ation misapplication misuse or other operating conditions outside of OMEGA s control Components in which wear is not warranted include but are not limited to contact points fuses and triacs OMEGA is p...