Technical Information

9.I FEEL button

Press this button to start I FEEL function and "     " will be displayed on the remote controller. After this function is set, the remote

 controller will send the detected ambient temperature to the controller and the unit will automatically adjust the indoor 

 temperature according to the detected temperature. Press this button again to close I FEEL function and "     " will disappear.

●  Please put the remote controller near user when this function is set. Do not put

●  Sleep3- the sleep curve setting under Sleep mode by DIY could be inquired:

The user could accord to sleep curve setting method to inquire the presetting sleep curve,

enter into user individuation sleep

 

 setting status, but do not change the tempera-ture, press “Turbo” button directly for confirmation. Note: In the above presetting or 

enquiry procedure, if continuously within 10s, there is no button pressed, the sleep curve setting within 10s, there is no button 

pressed,  the sleep curve setting status will be automatically quit and resume to display the original displaying. In the presetting or

enquiry procedure, press 

"ON/OFF" button, "Mode" button, "Timer" button or "Sleep" button, the sleep curve setting 

or enquiry status will quit similarly. 

Press this button to set clock time. "     " icon on remote controller will blink. Press "▲" or "    " button within 5s to set clock time. 

 Each pressing of "▲" or "    " button, clock time will increase or decrease 1 minute. If hold "▲" or "    " button, 2s later

,

time will change quickly. Release this button when reaching your required time. 
Press "CLOCK" button to confirm the time. "     " icon stops blinking.

Note:

● Clock time adopts 24-hour mode.

● The interval between two operation can’t exceeds 5s. Otherwise, remote contro-

   ller will quit setting status. Operation for

 

TIMER ON/TIMER OFF is the same.

11.CLOCK button

Note:

● Under on and off status, you can set TIMER OFF or TIMER ON simultaneously.

● Before setting TIMER ON or TIMER OFF, please adjust the clock time.

● After starting up TIMER ON or TIMER OFF, set the constant circulating valid.   

   After that, air conditioner will be turned on or turned off according to setting time. 

   ON/OFF button has no effect on setting. If you don’t need this function, please   use remote controller to cancel it.

 temperature or low temperature in order to avoid detecting inaccurate 

    the remote controller near the object of high 

When I FEEL function is turned on, the remote controller should be put within the area where indoor unit can receive the 

 signal sent by the remote controller.

 ambient temperature.    

 

TIMER ON button

   "TIMER ON" button can set the time for timer on.

 

After pressing this button, "     "

    remote controller blinks. Press "▲" or

   icon disappears and the word "ON" on

   "    " button to adjust

 

TIMER ON setting.

 

After each pressing "▲" or "    " button,

   

TIMER ON setting will increase or decrease 1min. Hold "▲" or "    " button, 2s

   later , the time will change quickly

 until reaching your required time. 

   Press "TIMER ON" to confirm it.

 

The word "ON" will stop blinking. "     " icon 

   resumes displaying. Cancel

 

TIMER ON: Under the condition that

 

TIMER ON is  started up, press "TIMER ON"

 button to cancel it.

● TIMER OFF button

   "TIMER OFF" button can set the time for timer off. After pressing this button,"     "

 on remote controller blinks. Press "▲" or 

   icon disappears and the word "OFF" 

   "    " button to adjust

 

TIMER OFF setting.

 

After each pressing "▲" or "    " button, 

   

TIMER OFF setting will increase or decrease 1min. Hold "▲" or "    " button, 2s 

   later , the time will change quickly 

until reaching your required time. 

   Press "TIMER OFF" word "OFF" will stop blinking. "     " icon resumes displaying. 

   Cancel TIMER OFF. Under the condition that TIMER OFF is started up, press

   "TIMER OFF" button to cancel it.

10.TIMER ON /

 

TIMER OFF button

12.QUIET button

Press this button, the Quiet status is under the Auto Quiet mode (display "     " and "AUTO" signal ) and Quiet mode 

(display "     " singal) and Quiet OFF (there is no signal of "     " displayed), after powered on, the Quiet OFF is defaulted. 

Note:

 

 

The Quiet function can be set up in all modes; Under the Quiet mode,the fan 

   speed is not available.

● When quiet function is selected:

   Under cooling mode: indoor fan operates at notch 4 speed. 10 minutes later or 

   when indoor ambient temperature≤28

Ƈ

, indoor fan will operate at notch 2 speed 

   or quiet mode according to the compari son between indoor ambinet temperature 

   and set temperature.

   Under heating mode: indoor fan operate s at notch 3 speed or quiet mode according   to the comparison between indoor

  ambient temperature and set temperature.

   actual cooling, heating or fan mode.

   Under dry, fan mode: indoor fan operates at quiet mode.

   Under auto mode: the indoor fan operates at the auto quiet mode according to 

Summary of Contents for CB432022800

Page 1: ...IEWQ ICHQ Series High Wall Inverter Technical Manual ...

Page 2: ...ooling and Heating Data Sheet in Rated Frequency 5 3 Outline Dimension Diagram 6 3 1 Indoor Unit 6 3 2 Outdoor Unit 7 4 Refrigerant System Diagram 8 5 Electrical Part 9 5 1 Wiring Diagram 9 5 2 PCB Printed Diagram 11 Appendix 22 Appendix 1 Reference Sheet of Celsius and Fahrenheit 22 Appendix 2 Configuration of Connection Pipe 22 Appendix 3 Pipe Expanding Method 23 Appendix 4 List of Resistance fo...

Page 3: ...1 Technical Information 1 Summary Part Ⅰ Technical Information Indoor Unit Outdoor Unit IEWQ036J3A RWI100 ICHQ036J3A RLH100 Remote Controller ...

Page 4: ...nit IEWQ036J3A RWI100 Indoor Unit Product Code CB434N14900 CB432N22800 Fan Type Cross flow Diameter Length DXL mm Φ108X522 7 Fan Motor Cooling Speed SH H MH M ML L SL r min 1550 1300 1200 1100 1000 950 850 Fan Motor Heating Speed SH H MH M ML L SL r min 1550 1300 1200 1100 1000 950 900 Output of Fan Motor W 70 Fan Motor RLA A 0 28 Fan Motor Capacitor μF Evaporator Form Aluminum Fin copper Tube Pip...

Page 5: ... mm 994X57 1X748 Fan Motor Speed rpm 880 Output of Fan Motor W 90 Fan Motor RLA A 0 65 Fan Motor Capacitor μF Air Flow Volume of Outdoor Unit m3 h 4000 Fan Type Axial flow Fan Diameter mm Φ550 Defrosting Method Automatic Defrosting Climate Type T1 Isolation I Moisture Protection IPX4 Permissible Excessive Operating Pressure for the Discharge Side MPa 4 3 Permissible Excessive Operating Pressure fo...

Page 6: ...h 7 5m Conditions Indoor DB20 C WB15 C Outdoor DB7 C WB6 C Indoor air flow High Pipe length 7 5m Conditions Indoor DB20 C WB15 C Outdoor DB7 C WB6 C Indoor air flow High Pipe length 5m Cooling Heating Cooling 32 33 35 36 38 43 40 41 42 100 105 95 90 85 80 75 70 65 60 55 50 Conditions Indoor DB27 C WB19 C Indoor air flow Super High Pipe length 7 5m Outdoor temp C Capacity ratio Heating 15 10 5 110 ...

Page 7: ...it Inlet and outlet pipe temperature of heat exchanger Fan speed of indoor unit Fan speed of outdoor unit Compressor frequency Hz Indoor Outdoor P MPa T1 C T2 C 27 19 35 24 36K 0 9 to 1 2 12 to 14 43 to 41 Super High High 56 Rated heating condition C DB WB Model Pressure of gas pipe connecting indoor and outdoor unit Inlet and outlet pipe temperature of heat exchanger Fan speed of indoor unit Fan ...

Page 8: ...6 Technical Information 3 Outline Dimension Diagram 3 1 Indoor Unit Model W H D 36K Unit mm W D 295 90 40 350 254 746 Φ70 Φ70 H 28K 90 150 54 168 5 462 159 5 Φ55 Φ55 54 1350 326 253 ...

Page 9: ...7 Technical Information 3 2 Outdoor Unit Unit mm 1003 790 395 610 920 370 427 ...

Page 10: ...tion Liquid pipe 1 4 6mm Gas pipe 5 8 16mm Indoor unit Outdoor unit COOLING HEATING 4 Way valve Discharge Suction Heat exchanger evaporator Heat exchanger condenser Valve Valve Liquid pipe side Gas pipe side Strainer Electric expand valve Strainer Capillary Compressor Accumlator ...

Page 11: ...ngle of horizontal lover for this model 60000700130505 3OHDVH GRQ W WRXFK DQ HOHFWURQLF FRPSRQHQW RU WHUPLQDO ZKHQ WKH PDFKLQH LV UXQQLQJ VWRSSLQJ RU KDV EHHQ SRZHUHG RII IRU OHVV WKDQ PLQXWHV WR SUHYHQW HOHFWULF VKRFN 287 225 81 7 8 1 1 2 5220 7 03 78 7 03 6 1625 6 1625 63 2 5 5 9 5 1 0 1 2 5 803 3 3 6 1 8 78 5220 3 63 63 0 3 02725 9 325 725 1 1 20 287 1 1 8 7 7 5 7 5 7 50 1 02725 67 33 1 83 2 1 ...

Page 12: ... RU KDV EHHQ SRZHUHG RII IRU OHVV WKDQ PLQXWHV WR SUHYHQW WKH ULVN RI HOHFWULF VKRFN 51 1 20 11 5 1 B 1 1 8 3 1 1 1 8 7 1 225 81 7 5 1 1 8 2 7 50 1 0 1 7 32 5 1 7 6 1625 203 9 8 35 17 5 8 7 2 5 3 1 1 02725 2 1 7 9 7 9 9 9 9 0 3 9 OHFWURQLF SDQVLRQ 9DOYH 3 1 3 5 1 0 1 7 29 5 2 3527 725 5 9 8 8 8 5 57 57 57 5 29 203 6 7 203 8 7 03 6 1625 28778 2875220 7 03 6 1625 867 7 03 6 1625 3 1 3 8 1 LURQ VKHOO...

Page 13: ...lay used for controlling wire 6 Auto key 7 up down swing interface 8 WIFI 9 Interface of ambient temperature sensor 10 Interface of tube temperature sensor 11 Display board 12 Interface of communication wire for indoor unit and outdoor unit 13 Interface of health function live wire 14 15 Fuse Applicable for some models Applicable for some models Interface of health function neutral wire Top view B...

Page 14: ...ure cooling temperature sensor 7 Terminal of low pressure protection 12 Terminal of live wire 3 Terminal of electronic expansion valve 8 Terminal of outdoor fan 13 Terminal of communication 4 Terminal of outdoor temperature sensor 9 Terminal of compressor electric heating 14 Terminal of grounding wire 5 Terminal of compressor overload protection 10 Terminal of 4 way valve 15 Terminal of neutral wi...

Page 15: ...roller 16 30 61 86 F Fan speed auto low speed low medium speed medium speed medium high speed high speed 3 FAN button This button is used for setting Fan Speed in the sequence that goes from AUTO to then back to Auto Auto Medium speed Low Medium speed Low speed High speed Medium High speed Note 4 TURBO button Under COOL or HEAT mode press this button to turn to quick COOL or quick HEAT mode icon i...

Page 16: ...culation sequence stated above Press this button can select left right swing angle Fan blow angle can be selected circularly as below button no display stops at current position 6 7 main unit setting temperature will increase 1 two hours setting temperature increa sed 2 setting temperature In Heat mode sleep status after run for one hour the setting temperature will decrease 1 two hours setting te...

Page 17: ...use remote controller to cancel it temperature or low temperature in order to avoid detecting inaccurate the remote controller near the object of high When I FEEL function is turned on the remote controller should be put within the area where indoor unit can receive the signal sent by the remote controller ambient temperature TIMER ON button TIMER ON button can set the time for timer on After pres...

Page 18: ... CLOCK buttons simultaneously to start up or turn off energy saving function When energy saving function is startedup SE will be shown on remote controller and air conditioner will adjust the set temperature automatically according to ex factory setting to reach to the best energy saving effect Press TEMP and CLOCK buttons simultaneously again to exit energy saving function Note Under energy savin...

Page 19: ...CK buttons simultaneously again to exit 8ćheating function heating function has been set under Replacement of batteries in remote controller THREE TIMERS TWO TIMERS TIMER CANCELLATION NOTE 1 Press the back side of remote controller marked Press uninterruptedly LIGHT button 6 times in 5 seconds thus we enter the Multi Timer mode as well as three minute counting down stars If three couples of times ...

Page 20: ...ure setting range is 16 30 and the indoor unit displays operation icon cooling icon and set temperature Protection Functions Antifreezing protection If the system is under antifreezing protection the compressor and the outdoor fan stops operation and the indoor fan operates at setting speed If antifreezing protection is eliminated and the compressor has been stopped for 3 minutes the unit will res...

Page 21: ...protection is detected the compressor and the outdoor fan will stop operation and the indoor fan will operate at low speed When the antifreezing protection is eliminated and the compressor has been stopped for 4 minutes the complete unit will resume its previous operation state Other protection Other protections are the same as those in cooling mode 3 Heating mode not available for cooling only ty...

Page 22: ...erate according to previous setting status Timer OFF If timer OFF is set at unit OFF the system will keep standby status If timer OFF is set at unit ON upon OFF time reaches the unit will stop operation Timer Change Although timer has been set the unit still can be turned on off by pressing ON OFF button of remote controller You can also set the timer once again and then the unit will operate acco...

Page 23: ...perature display returns some models if set temperature display is set by the remote controller present set temperature will be displayed 10 Locked protection to PG motor 9 Display When starting the fan if motor s rotational speed is slow for a period of time the unit will display locked and stop running to avoid auto protection for motor If the unit is at on status currently error code H6 will be...

Page 24: ...mbient temperature Fahrenheit display temperature o F Fahrenheit o F Celsius o C Fahrenheit display temperature o F Fahrenheit o F Celsius o C Fahrenheit display temperature o F Fahrenheit o F Celsius o C 32 33 32 0 55 56 55 4 13 79 80 78 8 26 34 35 33 8 1 57 58 57 2 14 81 80 6 27 36 35 6 2 59 60 59 15 82 83 82 4 28 37 38 37 4 3 61 62 60 8 16 84 85 84 2 29 39 40 39 2 4 63 62 6 17 86 87 86 30 41 42...

Page 25: ...teps A Cut the pip Confirm the pipe length according to the distance of indoor unit and outdoor unit Cut the required pipe with pipe cutter B Remove the burrs Remove the burrs with shaper and prevent the burrs from getting into the pipe C Put on suitable insulating pipe D Put on the union nut Remove the union nut on the indoor connection pipe and outdoor valve install the union nut on the pipe E E...

Page 26: ...3 10 63 72 2 439 111 0 737 5 63 46 34 10 2 73 2 358 112 0 717 4 60 23 35 9 779 74 2 28 113 0 697 3 57 18 36 9 382 75 2 206 114 0 678 2 54 31 37 9 003 76 2 133 115 0 66 1 51 59 38 8 642 77 2 064 116 0 642 0 49 02 39 8 297 78 1 997 117 0 625 1 46 6 40 7 967 79 1 933 118 0 608 2 44 31 41 7 653 80 1 871 119 0 592 3 42 14 42 7 352 81 1 811 120 0 577 4 40 09 43 7 065 82 1 754 121 0 561 5 38 15 44 6 791 ...

Page 27: ...5 84 61 34 13 59 73 3 144 112 0 956 4 80 31 35 13 04 74 3 04 113 0 93 3 76 24 36 12 51 75 2 94 114 0 904 2 72 41 37 12 76 2 844 115 0 88 1 68 79 38 11 52 77 2 752 116 0 856 0 65 37 39 11 06 78 2 663 117 0 833 1 62 13 40 10 62 79 2 577 118 0 811 2 59 08 41 10 2 80 2 495 119 0 77 3 56 19 42 9 803 81 2 415 120 0 769 4 53 46 43 9 42 82 2 339 121 0 746 5 50 87 44 9 054 83 2 265 122 0 729 6 48 42 45 8 7...

Page 28: ...1 32 101 3 22 15 362 9 24 51 41 63 10 93 102 3 13 14 342 8 25 49 19 64 10 54 103 3 04 13 323 9 26 47 08 65 10 18 104 2 96 12 306 2 27 45 07 66 9 83 105 2 87 11 289 6 28 43 16 67 9 49 106 2 79 10 274 29 41 34 68 9 17 107 2 72 9 259 3 30 39 61 69 8 85 108 2 64 8 245 6 31 37 96 70 8 56 109 2 57 7 232 6 32 36 38 71 8 27 110 2 50 6 220 5 33 34 88 72 7 99 111 2 43 5 209 34 33 45 73 7 73 112 2 37 4 198 3...

Page 29: ...OMEGA IEWQ HQ High Wall Inverter Technical Manual info otecomega com www otecomega com IEWQ CHQ I3A TM1R0622 info otecomega com www otecomega com ...

Reviews: