/5
Fig. 1.0
1.0 CS Test (Customer services)
1.1 Operations to enter into CS test mode :
1. Remove the battery
2. Wait for the LCD segments to disappear.
3. Hold the crown pressed in.
4. Insert the battery, the LCD displays «TEST 0».
5. Release the crown, test 0 is carried out.
6. Press the crown to perform the next test, the LCD
displays the number of the next test «TEST X» (see p. 7).
7. Release the crown to carry out the test.
Rate adjustment
Test 1 displays the current value of the rate correction.
This correction is calculated then saved in the movement
during production tests.
This test is also used to modify this correction value if
necessary. Every connection between the battery’s + pole
and the C+ or C- test points increases or decreases the
correction value and therefore adjusts the watch rate.
C-
C+
B pole
OMEGA SA
WORLD SERVICE ORGANIZATION
GT-19-C-069-E - A - 1666
/5
Speci
fi
c Information for calibre 1666