engineering units (°C or °F) or display resolution (XXX, XXX.X or X.XX).
Following are two diagrams: a) menu hierarchy with factory default settings
b) programming procedure.
Figure 7. Programming Procedures
3.6 Approximate Target Plate Temperature Transition Graph
The BB703 heat-up and cool-down characteristics are illustrated in the following
graph. The graph illustrates the approximate time required to make a transition
from one plate temperature to another. First determine the current plate
temperature and go to the corresponding row. Now decide the new target plate
temperature and go to the appropriate column. Note that there are X’s along the
diagonal where original and target temperatures are the same.
Figure 8. Approximate Target Plate Temperature Transition Times
3
1. To enter programming menu hold down the and keys, simultane-
ously, for 3 seconds. Upon entering the menu, the user is always located at
the “tUnE” parameter. This is the first parameter of MENU1.
2. Use the
and
keys to scan through the various parameters on a given
menu level.
3. Use the
key together with the
key or the
key to change a given
parameter.
4. To change menu levels, scan to the first parameter on a given menu level,
using the
key. Next, hold down the
key in addition to the
key
or the key to go to a different menu level.
5. To leave the programming menu and return to the normal operation
mode, hold down the
and
keys, simultaneously.
6. All parameters are saved, even when power is removed from the unit.
150F
300F
450F
600F
750F
150F
13 min. 15 min. 16 min. 16 min. 65.6C
300F
17 min.
6 min. 15 min. 16 min. 148.9C
450F
18 min. 8 min.
12 min. 16 min. 232.2C
600F
35 min. 19 min. 18 min.
15 min. 315.6C
750F
40 min. 24 min. 20 min. 16 min.
398.9C
65.6C
148.9C 232.2C 315.6C 398.9C
TO:
TO:
FROM:
FROM: