Logger Setting:

(Pic.5)

(Pic.3)

(Pic.4)

8

NOTE:

If software message box show as Pic2.Follow the next steps.

1.Click My computer Content in hardware content, click

””

Device manager to find the listed (COMx) listed under Ports

(COM & LPT as below with red line. If you may Prolific

USB-to-Serial Comm. Port , it means the logger is connected

to computer properly.

2. Remember the Comm port number and go back to software.
3 Click “Setting” ”Comm port “ select the port number as you

.

see from step 1, then press OK button.

9

BASIC:(Pic.3)

1:ID setting

Maximum 20 characters , name your logger press OK

button to confirm

Please  type in capital. Space is unacceptable.

2:Current Date/Time

Clock setting, the system automatically shows current date and

time of  your pc. Press OK  to confirm.

(Note: Schedule date & time refer to current pc date and time)

Please click OK to sync the meter’s date and time

every time.

ALARM&SENSOR:(Pic.4)

1.Appear the parameter.

HCHO model default with Temp. and RH sensor.

SETTING:(Pic.5)

1. Set sample point (K=1,000 multiple basis within total

memory points).

2.Set sample rate, start mode  to record:

Select “hour(1~6), “minute(0~59)”,“second(0~59)” time interval.

Select 5 start modes from:

Immediate (Logger start recording immediately)

Real-time(PC is always connected with the logger)

Key start/off (Start/stop recording by long pressing

SEL/R button)

Roll-over (when memory are full, logger covers the earliest memory

automatically)

Schedule (Select the date and time meter will start recording.)

3.Select Unit :

Select Temperature unit °C/°F for recording,

press OK to confirm.

Long press

10

  

Schedule start mode:

Select the date and time meter will start recording.

The recording start time as software’s current time not

meter’s. Please set up the current time correctly.

  

Real-time start mode:

1.After set start mode at real-time,datalogger starts login records.

When logger records, the green fan at left corner shows it is

under recording.(Meter should be connected with pc all the time,
under this mode.

)

2.In real-time mode, it shows “STOP” button  instead of

“DOWNLOAD” at the right corner.  Press STOP to stop

real-time recording.

Before exit software data has to be downloaded.

  

Key-start/off  mode:

Select the mode to record once long press

button for 3 seconds. Long press

R

/

L

E

S

R

/

L

E

S

button again to stop recording. Data has to be

downloaded before next key-start. LCD

display appear “Logging” at left corner.

After key off the recording, the data has to download

NOTE:

before restart the Key-Start function.

  Roll-over mode:

After Roll-over mode is selected. Press OK, the meter will start to

record. When the data is full, it will cover the earliest memory.

After download the data , long press

button to record

SEL/R

without reset up each parameter and selection.

Logger Status:

Before download data, press

to show ID,

LOGGER status

Records, Sample rate, Unit.

Once

button is pressed, recording is

NOTE:

Download

inactivated.

(pic.6)

11

Logger function:

Download data:

Press DOWNLOAD button, data download in few seconds.

Graph shows automatically

Please do not press DOWNLOAD button if you won’t

NOTE:

stop record. You can press LOGGER STATUS button to see

record points.

Retrieve file:

Press RETRIEVE FILE button to select file and show the graph.

Save data:

Press SAVE button to save txt.or csv.file. After save as txt.

may print as pdf. file if needed.

View Data Table

:

Press View button to get data table with details.(pic.6)

Print graph:

Press PRINT button and print graph. Follow the print setting

below to print full screen graph. Press OK to print pdf file.(pic.7)

Print Table Data:

Press table data, the screen shows the

record range, enter the start number to the

end number (For example: 1~500 or

200~1000...or leave it blank for printing

all data ).(pic.8)

Save each pdf. files with different names.


(pic.7)

(pic.8)

=

Screen graph zoom in

=

Ctrl

+

Screen graph zoom out

Mouse

Hold

Click

Shift

Click

Mouse

=

Move screen graph

Press

or

= Read each measurement .

Ctrl

+

Hold

Click

Ctrl

+

Hold

Mouse

12

Clear Data:

The data is stored in the memory till next setting start, meter

will clean previous data automatically. So if you start next

data logging, there is no way you can find the data you

haven't stored.

Line color selection:

1.Click the color beside the reading(Temp. RH. HCHO),

color box appear.

2.Move mouse to review and select color.

3.Click to save, the color appear on line and bar.

Zoom in/out&Move

NOTE:

May follow the line color selecting, the graph size will

go back to default.

Meas. Range
Audible alarm
Interfacce
LED(Green.Red)
Temp. range
RH%range
Resolution
Accuracy

Accuracy(HCHO)

Response time
Memory
Sensor life time

YES (Adjustable)

0.00-5.00 ppm (mg/m

3

)

10 ~ 90%RH

YES

AQM-101

USB

T90: Less than 30 seconds

Expected 3 years

0~50

°C

(32~122

°F

)

0.01ppm(HCHO) ,1

°C

/

°F

, (1%RH)

±1

°C

/2

°F

(Temperature), ±5% (10~90%RH)

±5% of r 0.03ppm (mg/m3)

( Under vaccum ,ventilated standard gas chamber

). Meet NOISH acceptance criterion /-25%

of the true value at th e95% confidence level.

Example: OSHA Formaldehyde regulation
0.10ppm ( EPA 0.08ppm), accuracy within

0.025ppm ( 0.075~0.125ppm)

32,000 points

13

SPECIFICATIONS

TROUBLE SHOOTING

(1) When meter appears break character, please find

out if meter ever dropped to the floor. If “yes”,

please contact with local distributor for technical service.

(2) Error codes:

Er1 : HCHO/Temp./RH sensor is failed

Er2 : HCHO/Temp./RH Over range

14

WARRANTY

This instrument is warranted for two years from the date of

purchase(One year limited warranty applies to cables). A Return

Authorization letter must be issued before returning for any reason.

This warranty does not apply to defects resulting from action of

the user such as misuse, abuse, alteration neglect, improper

wiring, improper maintenance or repair, or unauthorized

modification, damage resulting from leaking batteries, operation

outside of specification.

During the warranty period the manufacturer reserved the right to

decide either to repair or replace the product. The meters are to be

returned along with good packing to prevent any damage in

shipment and insured against possible damage or loss.

The two years’ warranty doesn’t apply to:

Accessories and batteries (not covered by  warranty).

Claims is not acceptable for improper use (including

adaptation to particular applications not foreseen in

the instructions manual) or improper combination

with incompatible accessories or equipment, or by

previous attempts for repair carried out by none

skilled or unauthorized personnel.

Sensor damaged by user improper use

(Watering,Burning,Condensation....)

HCHO LEVELS AND GUIDELINES

Non-enforced reference levels:

a) 0.03 ppm-Average outdoor level.

b) 0.10 ppm-Recommend upper limit for residences by

ASHRAE , ANSI,EPA,NIOSH for STEL.

c) 0.40 ppm-Recommended upper limit for manufactured homes.

d) 0.50 ppm-OSHA workplace limit.

e) 0.75 ppm-OSHA TWA limit.

f ) 0.80 ppm-Level at which most people first detect odor.

g) 2.00 ppm-OSHA STEL limit.

 

WARRANTY/DISCLAIMER

OMEGA  ENGINEERING,  INC.  warrants  this  unit  to  be  free  of  defects  in  materials 

and  workmanship  for  a  period  of 

13  months

  from  date  of  purchase.  OMEGA’s 

WARRANTY adds an additional one (1) month grace period to the normal 

one (1) 

year  product  warranty

 to cover handling and shipping time. This ensures that 

OMEGA’s customers receive maximum coverage on each product. 
If  the  unit  malfunctions,  it  must  be  returned  to  the  factory  for  evaluation. 

OMEGA’s  Customer  Service  Department  will  issue  an  Authorized  Return 

(AR)  number  immediately  upon  phone  or  written  request.  Upon  examination 

by  OMEGA,  if  the  unit  is  found  to  be  defective,  it  will  be  repaired  or  replaced 

at  no  charge.  OMEGA’s  WARRANTY  does  not  apply  to  defects  resulting  from 

any  action  of  the  purchaser,  including  but  not  limited  to  mishandling, 

improper  interfacing,  operation  outside  of  design  limits,    improper  repair,  or 

unauthorized modification. This WARRANTY is VOID if the unit shows evidence of  

having  been  tampered  with  or  shows  evidence  of  having  been  damaged  as  a 

result  of  excessive  corrosion;  or  current,  heat,  moisture  or  vibration;  improper 

specification;  misapplication;  misuse  or  other  operating  conditions  outside  of 

OMEGA’s control. Components in which wear is not warranted, include but are not  

limited to contact points, fuses, and triacs.

OMEGA  is  pleased  to  offer  suggestions  on  the  use  of  its  various  products. 

However, OMEGA neither assumes responsibility for any omissions or errors 

nor assumes liability for any damages that result from the use of its products 

in accordance with information provided by OMEGA, either verbal or written. 

OMEGA warrants only that the parts manufactured by the company will be as 

specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR  

REPRESENTATIONS  OF  ANY  KIND  WHATSOEVER,  EXPRESSED  OR 

IMPLIED,  EXCEPT  THAT  OF  TITLE,  AND  ALL  IMPLIED  WARRANTIES 

INCLUDING  ANY  WARRANTY  OF  MERCHANTABILITY  AND  FITNESS  FOR 

A  PARTICULAR  PURPOSE  ARE  HEREBY  DISCLAIMED.  LIMITATION  OF  

LIABILITY:  The  remedies  of  purchaser  set  forth  herein  are 

exclusive,  and  the  total  liability  of  OMEGA  with  respect  to  this  order, 

whether  based  on  contract,  warranty,  negligence,  indemnification, 

strict  liability  or  otherwise,  shall  not  exceed  the  purchase  price  of  the  

component upon which liability is based. In no event shall OMEGA be liable 

for consequential, incidental or special damages.

CONDITIONS:  Equipment sold by OMEGA is not intended to be used, nor shall it 

be used: (1) as a “Basic Component” under 10 CFR 21 (NRC), used in or with any 

nuclear  installation  or  activity;  or  (2)  in  medical  applications  or  used  on  humans. 

Should  any  Product(s)  be  used  in  or  with  any  nuclear  installation  or  activity, 

medical  application,  used  on  humans,  or  misused  in  any  way,  OMEGA  assumes 

no responsibility as set forth in our basic WARRANTY/DISCLAIMER language, and, 

additionally,  purchaser  will  indemnify  OMEGA  and  hold  OMEGA  harmless  from 

any liability or damage whatsoever arising out of the use of the Product(s) in such 

a manner.

Reviews: