background image

 

 

OMEGA ALTISE 

 

 

CONTROLS 

 
 

FUNCTION BUTTONS: 

 
 
 
 
 
 

 
 
 
 
 
 

 
  CONTROL PANEL ON FRONT OF BODY                                                                        REMOTE CONTROL 
 
There are 6 function buttons on the control panel at the front of the main body and on the remote control. Make sure the 
power has been connected (indicator 6 will light up to indicate this) and the water tank has been filled. 
1)

 

Off button (9): This button turns the fan off when pressed. The Fan Function icon will turn off. 

2)

 

On/Speed button (10): When connected to the power supply, the “Power on” indicator (6) will light up. Press the 
On/Speed button to start the fan on slow speed. The digital display (1) will show the low speed as “1”. The Fan Function 
icon (2) will also light up. Press the button a second time for medium speed (shown as “2”) and a third time for high 
speed (displayed as “3”). Pressing once more will cycle the speed back to low. 

3)

 

Mist button: This button turns the mist function on and off. Press the button (11) once to start the misting function (with 
or without the fan working) and the mist will start to come out of the misting plate. The Misting Function icon (8) will also 

light up. Press the button another time and the mist will stop (Misting Function icon (8) will turn off). Note that the 
amount of mist may start off a little low, which is normal. 

4)

 

Ioniser button: This button turns the Ioniser on and off. Press the Ioniser button (12) once to turn the function on (the 
Ioniser function button (4) will light up). Press a second time to turn the function off. 

5)

 

Rotate button: This button turns the rotation of the front venting on and off. With the fan running, press the Rotate 
button (13) once to start the venting rotating (the Rotation icon (3) will light up), and again to turn it off. 

6)

 

Timer: This button is used to set up the timer for the fan and mist functions (the Ioniser function is not affected by the 
timer). First start the fan and/or mist function. Press the Timer button (14) once. The first digital display (1) will change 
to “H” and the Timer display (5) will show the current timer period (1). The Timer button can be pressed again to 
increase the timer period for up to 9 hours (in 1 hour increments). Pressing once more after the timer has reached 9 
hours will reset the timer to zero. Once set, the misting will fan can be left to run, with the timer counting down & 
stopping the function(s) at the end of the set time. The appliance can still be turned off with the Off button. 

 

OPERATING THE MISTING FAN: 

 

With the power cord plugged in, the power switched on, and the water tank full, the misting fan is now ready for operation. 

a)

 

To use the fan, press the On/Speed button (starts at low speed). Press again to cycle through the speeds. To turn the 
fan off, press the Off button. 

b)

 

To start the fan vent rotating, press the Rotate button once…press a second time to turn it off. The direction of the 
venting can be adjusted in the same way, or by hand. 

c)

 

The misting function can be turned on & off using the Mist button. This forces water droplets through the mist cover, to 
increase the humidity of the air. This can be used with the fan running to spread the moisture faster, or with the fan off. 
Make sure that the water tank is full (this can be seen through the water level indicator at the front of the main body). 
Note that it takes a little while for the full force of the misting function to start up – a lower amount of mist at start-up 
is normal. 

d)

 

The Ioniser function can be turned on & off with the Ioniser button. This function creates negatively charged ions which 

float through the air, attracting airborne particles & acting as an air purifier. 

e)

 

A timer for the fan and/or mist function can be set by pressing the timer button (each press of the button increases the 
time by an hour up to 9 hours. One more press resets the timer to 0 (continuous)). The display shows the remaining 
time when the timer is active. The timer function does not affect the other functions. 

Summary of Contents for altise AM360R

Page 1: ...OMEGA ALTISE OPERATION MAINTENANCE AND SAFETY INSTRUCTIONS FOR OMEGA ALTISE MISTING FAN MODELS INCLUDE AM360R ...

Page 2: ...onnect with the power source Always grasp the plug to pull it out Do not remove the plug from the power source with wet hands or if water has spilt on the ground where you are standing 8 Do not run power cords under rugs or other combustible materials Do not place power cords in areas where they can be a tripping hazard 9 Do not insert any objects into the appliance as it may cause an electric sho...

Page 3: ... plastic bag and the carton and unwind the cord to its full length 2 Place the appliance onto a stable flat and dry surface 3 Fill the water tank with cool water 4 Plug the cord set into a 230 240V A C 50Hz earthed electrical outlet Turn the power on at the electrical outlet 1 LED Display 2 Control Buttons 3 Control Panel 4 Air Guide wheel 5 Misting Plate 6 Front Cover 7 Water Level Indicator 8 Pa...

Page 4: ...d or mist function Press the Timer button 14 once The first digital display 1 will change to H and the Timer display 5 will show the current timer period 1 The Timer button can be pressed again to increase the timer period for up to 9 hours in 1 hour increments Pressing once more after the timer has reached 9 hours will reset the timer to zero Once set the misting will fan can be left to run with ...

Page 5: ...ops of sewing machine oil between the bearing and motor shaft Do not disassemble the fan in any other manner STORAGE Store the misting fan with these instructions in a cool dry place TROUBLESHOOTING Fault Possible Cause Solution Fan does not work when plugged in Main power off fuses blown Check power is on at meter Motor failed to start Select a higher fan speed Power rating too low Increase power...

Page 6: ...chase as well as other important documents about this product for future reference Due to continual product development Omega Altise reserves the right to alter specifications or appearances without notice Dispose of packaging responsibly recycle where facilities are available ...

Page 7: ...OMEGA ALTISE ...

Page 8: ...OMEGA ALTISE A division of Shriro Australia Pty Ltd 104 Vanessa St Kingsgrove NSW 2208 In Australia 1300 795 572 In New Zealand 09 415 6000 www omegaaltise com IM Ref AM360R 26 2014 05 ...