3
SET UP
(Refer to Figure 1 & 2)
1. Remove the plug on oil port, connect 3/8" NPTF
hydraulic connection to oil port, i.e. coupler, hydraulic
hose, fitting etc. Ensure the oil ports and thread
connections are clean before connecting to the
hydraulic system.
NOTICE
Always secure threaded connections with
non-hardening pipe thread compound. Take care not to
introduce compound into port orifices. Tighten securely
to prevent accidental removal of components while in
use.
2. Connect the hydraulic connection to hydraulic
pump.
3. Install a pressure gauge to monitor the system
pressure.
DO NOT
exceed rated pressure of 10,000 psi.
Figure 2 - Typical Installation Illustration
Bead Breaker
*Hydraulic Connections
i.e. Couplers and fitting
(3/8"-18 NPTF)
*Air Actuated
Hydraulic Pump
*Hydraulic Hose
Air Supply Inlet
(*) Items not included with unit
BEFORE USE
1. Verify that the product and the application are
compatible, if in doubt call Omega Technical Service
(888) 332-6419.
2. Before using this product, read the operator's manual
completely and familiarize yourself thoroughly with
the product, its components and recognize the
potential hazards associated with its use.
3. Replace worn or damaged parts and assemblies with
factory authorized replacement parts only. Lubricate
as instructed in Maintenance Section.
4. Use adequate eye protection when operating or near
this equipment.
!