background image

16

17

En

gl

is

h

Quartz watch

Operating instructions

2

 

The crown has 3 positions:
1. 

Normal position (wearing position):

 when the crown is positioned 

against the case, the crown ensures that the watch is water-resistant.

2. 

Time zone and correcting the date:

 pull the crown out to posi-

tion 2. Turn the crown forwards or backwards, the hour hand moves 

forwards or backwards in one-hour jumps. The date can be moved 

forwards or backwards by moving the hour hand past midnight 

accordingly. Push the crown back to position 1.

3. 

Time setting:

 pull the crown out to position 3. The seconds hand 

will stop. Turn the crown forwards or backwards. Synchronise the 

seconds by pushing the crown back to position 1 to coincide with 

a given time signal.

For calibres 1424, 1426, 1530, 1532, 4561 and 4564, the end of bat-

tery life is indicated by the seconds hand making 4-second jumps. The 

watch will continue to function for several days, but the battery must 

be removed and replaced by an authorised 

OMEGA

 service agent 

as soon as possible. 

The hours, minutes, seconds and chronograph functions are driven  

by 4 motors using conventional quartz technology.

The crown has 3 positions:

Watch functions:

1. 

Normal position (wearing position):

 when the crown is posi-

tioned against the case, the crown guarantees the watch is water-

resistant. 

2. 

Time zone correction or 30 minutes totaliser hand initiali-

sation.

3. 

Time setting:

 pull the crown out to position 3. The seconds hand 

will  stop. Turn  the  crown  forwards  or  backwards.  Synchronise 

the  seconds  by  pushing  the  crown  into  position  1  to  coincide 

with a given time signal; resetting the 1/10th of a second and  

60 second totalisers.

Chronograph functions:

Allows the time to be read off to 

1/10th of a second up to 30 minutes  

in  the  simple,  addition  or  split 

modes  (reading  split  times,  inter-

mediate times).

Simple timing function

 (crown in position 1):

• 

Pusher A:

 start – stop (read time)

• 

Pusher b: 

reset

5200

Omega

 CALIbRE 5200

2 Operating instructions

Quartz chronograph

 CALIbRES 1424, 1538   

(fig. I)

01-OMEGA_V14-I_EN.indd   16-17

16/05/12   14:01:18

Summary of Contents for 1376

Page 1: ...E 14...

Page 2: ...rs 2403 8401 8421 A A A 2300 Omega Number of calibers 2300 2005 Omega Number of calibers 1376 1456 2005 2006 2007 8602 xxxx xxxx xxxx 8612 xxxx xxxx xxxx xxxx xxxx Omega MONDAY Number of calibers 8602...

Page 3: ...nter Minutenz hler Licznik minut Minutov s ta Po tadlo min t Percsz ml l Minutiloendur Hour counter Stundenz hler Licznik godzin Hodinov s ta Po tadlo hod n rasz ml l Tunniloendur Day counter Datumsan...

Page 4: ...403 8401 8421 23 Manual winding chronograph Calibres 1861 1863 1866 3200 3201 3203 3604 24 Self winding chronograph with or without date Calibres 3202 3220 3330 26 Self winding chronograph with date C...

Page 5: ...er states and in any countries with corresponding legislation 1 Introduction What must I do to ensure that my OMEGA watch provides me with excellent service for many years Magnetic fields avoid placin...

Page 6: ...atch This manufacturer s warranty does not cover the life of the battery normal wear and tear and ageing for example scratched crystal alteration of the colour and or material of non metallic straps a...

Page 7: ...and forty eight 48 months for watches with a co axial escapement and SI14 balance spring as well as for watches with the caliber 8500 or 8501 from the date of purchase under the terms and conditions...

Page 8: ...tained in the booklet provided with this watch and on the OMEGA website www omegawatches com does NOT apply to you and is replaced by this Australian New Zealand Warranty referred to below as the Warr...

Page 9: ...nty Introduction Please be aware that Goods presented for repair may be replaced by refurbished goods of the same type rather than being repaired Refurbished parts may be used to repair the goods Any...

Page 10: ...arranty HOW TO MAKE A CLAIM UNDER THIS WARRANTY To make a claim under this Warranty we recommend that you wrap your OMEGA watch carefully so as to avoid any damage and send it by registered mail or dr...

Page 11: ...tery must be removed and replaced by an authorised OMEGA service agent as soon as possible The hours minutes seconds and chronograph functions are driven by 4 motors using conventional quartz technolo...

Page 12: ...nsures that the watch is water resistant Occasional winding if the watch has not been worn for 60 hours or more wind it up with the crown in position 1 2 Time zone and correcting the date pull the cro...

Page 13: ...o not quit setting mode if the displays day and date are not properly centred in their windows calibreS 1120 2500 2507 2520 2610 8520 8521 fig I calibre 2627 fig V calibre 2300 fig X Manual self windi...

Page 14: ...f winding watch 2 Operating instructions 2627 Omega calibreS 2005 2006 2007 fig IV calibres 2403 8401 8421 fig VIII The crown has 2 positions 1 Normal position wearing position when the crown is posit...

Page 15: ...h functions Pusher A start stop start stop etc Timing to 1 6 of a second for up to 12 hours for the calibres 1861 1863 1866 3604 Timing to 1 8 of a second up to 30 minutes for the calibre 3200 3203 Ti...

Page 16: ...a neously calibre 3202 calibre 3220 fig XIII Self winding chronograph with date Operating instructions 2 calibreS 1151 3606 fig XI calibre 3304 fig XX The crown has 3 positions Watch functions 1 Norma...

Page 17: ...es 3301 3303 and 3313 Self winding chronograph with date Operating instructions 2 Self winding chronograph with date Operating instructions 2 The crown has 3 positions 1 Normal position wearing positi...

Page 18: ...sition 1 Chronograph functions Pusher A start stop start stop etc Timing to 1 8 of a second for up to 12 hours Self winding split seconds chronograph Operating instructions 2 Pusher B reset after a st...

Page 19: ...structions 2 2 Setting the time zone and correcting the date pull the crown out to position 2 Turn the crown forwards or backwards and the hour hand will move forwards or backwards by 1 hour intervals...

Page 20: ...depends on the individual habits of the wearer and can therefore vary A qualified OMEGA watchmaker can adjust the precision of a watch to within the OMEGA tolerances which are from 1 to 6 seconds per...

Page 21: ...ed with a valve specially developed by OMEGA 30 4 0 35 3 0 25 60 45 5 0 55 15 5 1 0 30 10 20 60 20 40 12 6 9 3 PROFESSIONAL CHRONOMETER 300m 1000ft 8 SWISS MADE fig 1 q Helium escape valve Specific se...

Page 22: ...mple calculating the number of heart beats per minute Start the chronograph count the heart beats and stop it at the beat correspon ding to the scale graduations of your chronograph here to the 30th b...

Page 23: ...2 put the watch on your wrist and close the clasp by pushing on it with your thumb until you hear a click fig 2 fig 3 Using the rotating bezel fig 4 keep the pusher A pressed down to turn the bezel U...

Page 24: ...e primary battery cell Russian customs Not water resistant d q j b V O xxxx l P U c a i S Z k m h o r t g N R Water resistant to a relative pressure of 3 bar 30 metres 100 feet Water resistant to a re...

Reviews: