background image

Servicing North America:

USA:

One Omega Drive, Box 4047

ISO 9001 Certified

Stamford, CT 06907-0047
Tel: (203) 359-1660

FAX: (203) 359-7700

e-mail: [email protected]

Canada:

976 Bergar
Laval (Quebec) H7L 5A1
Tel: (514) 856-6928

FAX: (514) 856-6886

e-mail: [email protected]

For immediate technical or application assistance:

USA and Canada:

Sales Service: 1-800-826-6342 / 1-800-TC-OMEGA

SM

Customer Service: 1-800-622-2378 / 1-800-622-BEST

SM

Engineering Service: 1-800-872-9436 / 1-800-USA-WHEN

SM

TELEX: 996404   EASYLINK: 62968934   CABLE: OMEGA

Mexico and
Latin America:

Tel: (95) 800-TC-OMEGA

SM

FAX: (95) 203-359-7807 

En Espan˜ol: (203) 359-1660 ext: 2203

e-mail: [email protected]

Servicing Europe:

Benelux:

Postbus 8034, 1180 LA Amstelveen, The Netherlands
Tel: (31) 20 6418405

FAX: (31) 20 6434643

Toll Free in Benelux: 06 0993344
e-mail: [email protected]

Czech Republic:

Ostravska 767, 733 01 Karvina
Tel: 42 (69) 6311899

FAX: 42 (69) 6311114

e-mail: [email protected]

France:

9, rue Denis Papin, 78190 Trappes
Tel: (33) 130-621-400

FAX: (33) 130-699-120

Toll Free in France: 0800-4-06342
e-mail: [email protected]

Germany/Austria:

Daimlerstrasse 26, D-75392 Deckenpfronn, Germany
Tel: 49 (07056) 3017

FAX: 49 (07056) 8540

Toll Free in Germany: 0130 11 21 66
e-mail: [email protected]

United Kingdom:

25 Swannington Road,

P.O. Box 7, Omega Drive,

ISO 9002 Certified

Broughton Astley, Leicestershire,

Irlam, Manchester,

LE9 6TU, England

M44 5EX, England 

Tel: 44 (1455) 285520

Tel: 44 (161) 777-6611

FAX: 44 (1455) 283912

FAX: 44 (161) 777-6622

Toll Free in England: 0800-488-488

e-mail: [email protected]

omega.com

TM

OMEGA

®

OMEGAnet

SM

On-Line Service 

Internet e-mail

http://www.omega.com [email protected]

It is the policy of OMEGA to comply with all worldwide safety and EMC/EMI regulations that 
apply. OMEGA is constantly pursuing certification of its products to the European New Approach
Directives. OMEGA will add the CE mark to every appropriate device upon certification.

The information contained in this document is believed to be correct but OMEGA Engineering, Inc. accepts 
no liability for any errors it contains, and reserves the right to alter specifications without notice.

WARNING: 

These products are not designed for use in, and should not be used for, patient connected applications.

Summary of Contents for LV-1101

Page 1: ...http www omega com e mail info omega com User sGuide LV 1 101 LV 1 102 Non Magnetic Liquid Level Switches...

Page 2: ...otherwise shall not exceed the purchase price of the component upon which liability is based In no event shall OMEGA be liable for consequential incidental or special damages CONDITIONS Equipment sold...

Page 3: ...ee in France 0800 4 06342 e mail france omega com Germany Austria Daimlerstrasse 26 D 75392 Deckenpfronn Germany Tel 49 07056 3017 FAX 49 07056 8540 Toll Free in Germany 0130 11 21 66 e mail germany o...

Page 4: ...OMEGA Customer Service Department When you receive the shipment inspect the container and equipment for signs of damage Note any evidence of rough handling in transit Immediately report any damage to...

Page 5: ...single float design the LV 1102 featurs a two float design Features Rugged Industrial Design Non Magnetic Design Suitable For Rusty Environments 15A SPDT Switch Directly Controls Pump Continuously Adj...

Page 6: ...lays nominal difference flow between the two relay actuation points is 5 Electrical Cable Fitting Water resistant strain relief for cable diameter 250 025 Wetted Parts Model LV 1101 red brass body pho...

Page 7: ...o adjust the buoyancy turn the leadscrew CLOCKWISE until the switch is actuated Lower the liquid level until the float is clear of the liquid and the switch is de actuated Raise the liquid level again...

Page 8: ...il the end of the jacket is flush with the inboard end of the cable fitting Grip the cable to prevent rotation and thread the gland nut onto the cable fitting to seal the grommet tightly to the cable...

Page 9: ...R than the set point power to the load is interrupted when the liquid level is ABOVE the set point Figure 2 Wiring Schematic for power applied to the load when the liquid level is HIGHER than the set...

Page 10: ...6...

Page 11: ...Notes 7...

Page 12: ...ccessories Benchtop Laboratory Meters Controllers Calibrators Simulators Pumps Industrial pH Conductivity Equipment DATA ACQUISITION Data Acquisition Engineering Software Communications Based Acquisit...

Reviews: