background image

4

WARNING: Disconnect all power to the unit before

installing Plug-in cards.

Adding Option Cards

The LDP63100 series meters can be fitted with up to three optional plug-in

cards. The details for each plug-in card can be reviewed in the specification
section of the included manual. Only one card from each function type can be
installed at one time. The function types include Setpoint Alarms (LDP6-CDS),
Communications (LDP6-CDC), and Analog Output (LDP6-CDL). The plug-in
cards can be installed initially or at a later date. 

SETPOINT ALARMS PLUG-IN CARDS (LDP6-CDS)

The LDP63100 series has 4 available setpoint alarm output plug-in cards.

Only one of these cards can be installed at a time. (Logic state of the outputs can
be reversed in the programming.) These plug-in cards include:

LDP6-CDS10 - Dual Relay, FORM-C, Normally open & closed
LDP6-CDS20 - Quad Relay, FORM-A, Normally open only
LDP6-CDS30 - Isolated quad sinking NPN open collector
LDP6-CDS40 - Isolated quad sourcing PNP open collector

ANALOG OUTPUT PLUG-IN CARD (LDP6-CDL)

Either a 0(4)-20 mA or 0-10 V retransmitted linear DC output is available

from the analog output plug-in card. The programmable output low and high
scaling can be based on various display values. Reverse slopes output is possible
by reversing the scaling point positions.

LDP6-CDL10 - Retransmitted Analog Output Card

COMMUNICATION PLUG-IN CARDS (LDP6-CDC)

A variety of communication protocols are available for the LDP63100 series.

Only one of these cards can be installed at a time. When programming the unit
via Crimson, the RS232 or RS485 Cards must be used.

PROGRAMMING SOFTWARE

DP6-SOFT is a Windows

®

based program that allows configuration of the

LDP63100 meter from a PC. This software offers standard drop-down menu
commands, that make it easy to program the LDP63100 meter. The program can
then be saved in a PC file for future use. A serial plug-in card is required to
program the meter using the software.

5. 

CERTIFICATIONS AND COMPLIANCES

:

SAFETY

UL Recognized Component, File #E313607, UL61010A-1, CSA C22.2
No. 1010-1

Recognized to U.S. and Canadian requirements under the Component
Recognition Program of Underwriters Laboratories, Inc.

UL Listed, File #E313547, UL508, CSA C22.2 No. 14-M95

LISTED by Und. Lab. Inc. to U.S. and Canadian safety standards

Type 4X Indoor Enclosure rating (Face only), UL50

IEC 61010-1, EN 61010-1: Safety requirements for electrical equipment

for measurement, control, and laboratory use, Part 1.

IP65 Enclosure rating (Face only), IEC 529

ELECTROMAGNETIC COMPATIBILITY

EMC specifications determined by the model.

6. 

ENVIRONMENTAL CONDITIONS

:

Operating Temperature Range: Determined by the model
Storage Temperature Range: -40 to 60°C
Operating and Storage Humidity: 0 to 85% max. RH (non-condensing)
Altitude: Up to 2000 meters

7. 

MOUNTING REQUIREMENTS

:

Max. panel thickness is 0.375" (9.5 mm)
Min. panel thickness for NEMA 4/IP65 sealing is 0.060" (1.52 mm)

8. 

MODULE INSTALLATION

:

24-pin shrouded connector on LDP63100 engages connector on input module
upon installation. Shroud ensures proper alignment by providing a lead-in for
the module connector. 

9. 

CONNECTIONS

: Wiring connections are made to the LDP63100 terminal

block and input module via high compression cage-clamp terminal blocks.

Input Module Wiring

: Instructions are provided in the included bulletin. 

LDP63100 Terminal Block Wiring

:

Wire Strip Length: 0.3" (7.5 mm)
Wire Gage: 30-12 AWG copper wire
Maximum Torque: 5-7 inch-lbs (0.58-0.81 N-m)

CAUTION: DISCONNECT ALL POWER BEFORE
INSTALLING OR REMOVING MODULE

10. 

CONSTRUCTION

: Aluminum front panel, enclosure, and rear cover with

textured black polyurethane paint for scratch and corrosion resistance
protection. Sealed front panel meets NEMA 4X/IP65 specifications for
indoor use when properly installed. Installation Category II, Pollution Degree
2. Panel gasket and keps nuts included. 

11. 

WEIGHT

: 5 lbs (2.25 kg) (

less module

)

OPTIONAL PLUG-IN CARDS AND ACCESSORIES 

LDP6-CDC4C - Modbus (Connector)

LDP6-CDC40 - Modbus (Terminal)

LDP6-CDC1C - RS485 Serial (Connector)
LDP6-CDC2C - RS232 Serial (Connector)

LDP6-CDC10 - RS485 Serial (Terminal)
LDP6-CDC20 - RS232 Serial (Terminal)

Summary of Contents for LDP63100

Page 1: ...L LD DP P6 63 31 10 00 0 Extra L Large D Display omega com e mail info omega com For latest product manuals omegamanual info User sGuide Shop online at LP0689X...

Page 2: ...megashop cz Germany Austria Daimlerstrasse 26 D 75392 Deckenpfronn Germany TEL 49 0 7056 9398 0 FAX 49 0 7056 9398 29 Toll Free in Germany 0800 639 7678 e mail info omega de United Kingdom One Omega D...

Page 3: ...IFICATIONS Input specifications wiring and programming information is contained in the corresponding literature shipped with the ordered model 1 DISPLAY 4 101 mm Red LED 5 Digit 19999 to 99999 2 POWER...

Page 4: ...CATIONS AND COMPLIANCES SAFETY UL Recognized Component File E313607 UL61010A 1 CSA C22 2 No 1010 1 Recognized to U S and Canadian requirements under the Component Recognition Program of Underwriters L...

Page 5: ...ewdriver blade 3 16 or 1 4 into the narrow slot between the LDP63100 rear cover plate and the module s plastic cover as illustrated in Figure 1 Twist the screwdriver in the direction shown to disengag...

Page 6: ...nstall 14 10 32 keps nuts supplied and tighten evenly for uniform gasket compression Do not over tighten the nuts By using additional mounting accessories the LDP63100 can be surface wall mounted susp...

Page 7: ...via the terminal block to allow unit programming A minimum of 3 switches would be required Each external switch must be wired between the key and the common terminal Optional Programming Remote LDP6 P...

Page 8: ...them 90 degrees clockwise until the notches engage with the lips of the channel The bolts and washers provided allow mounting to surfaces to thick 6 4 to 12 7 mm Use longer bolts for mounting to thick...

Page 9: ...the instructions included with the personality board 7 Remove the center section of the rear panel gasket Apply the gasket to the rear panel of the enclosure by inserting the 8 32 screws through the p...

Page 10: ...C power LDP63100 DC True RMS AC Current and Volt Inputs 85 250 VAC power LDP63100 AC Process Input 85 250 VAC power LDP63100 E Strain Gage Input 85 250 VAC power LDP63100 S ACCESSORIES LDP631 SHR Shro...

Page 11: ...therwise shall not exceed the purchase price of the component upon which liability is based In no event shall OMEGA be liable for consequential incidental or special damages CONDITIONS Equipment sold...

Page 12: ...rs Turbine Paddlewheel Systems Totalizers Batch Controllers pH CONDUCTIVITY pH Electrodes Testers Accessories Benchtop Laboratory Meters Controllers Calibrators Simulators Pumps Industrial pH Conducti...

Reviews: