User’s Manual DRF Series

GENERAL INFORMATION

The DRF series of Isolated Signal
Converters,  allow to convert process
signals, temperatures, electrical signals,
etc, to current loops or voltage signals for
further retransmision, while introducing
into the system galvanic isolation barriers
between the input, the output and the
power supply circuits.

The DRF series of Isolated Signal
Converters, offer an excellent relation
between signal conversion speed and
measurement accuracy. Offering up to a
0.2% accuracy and down to 70ms
response time, these units can process
information coming from probes or
transducers, in such a way that can be
quickly retransmitted in a fast and
accurate form to remote data acquisition
systems or PLC’s. The isolated signal
converters of the DRF series are ideal to
integrate into 12 bit data acquisition
systems.

Its powerful galvanic isolation of 3500 V
introduces high security to the measuring
systems, preventing the propagation of
those phenomenon which usually cause
damage, such as transient peaks or
energy shocks in any of the circuits of the
system. The galvanic isolation also acts
as a strong CE barrier. The decoupling
created between the circuits avoids
pernicious effects on the output, such as
ground loops or signal leaks, which distort
the acquired data and are extremely
difficult to isolate once introduced into the
signal.

The isolation offered by the DRF series
of Isolated Signal Converters is a 3 way
isolation. Thus, all the benefits exposed
above are applicable to any of the three
circuits composing the instrument : input,
output and power.

Recalibration of the instruments is realized
in a fast and easy way. Opening the front
cover grants access to the configuration
jumpers. Additional Span and Offset
potentiometers are directly accessible
from the frontal part. These potentiometers
are highly decoupled, minimizing the
iterations needed to obtain a correct
adjustment.

In order to obtain a higher and quickest
benefit of the DRF units, we recommend
you to read carefully the information
provided in this manual before proceeding
to the installation of the instrument. In this
manual you will find all technical data,
both electrical and mechanical, needed
for a correct instalation and utilization.

Note : The DRF Series Isolated Signal
Converters have a characteristics label
attached on the side of the instrument.
Check that this information matches
with your requirements for the specific
application, and especially check the
value and type of the Power Supply.

Summary of Contents for DRF-POT

Page 1: ...omega com e mail info omega com For latest product manuals omegamanual info Shop online at DRF POT FOR POTENTIOMETER INPUT DRF RES FOR RESISTANCE INPUT DRF Series Signal Conditioners User sGuide...

Page 2: ...cques Cartier 78280 Guyancourt France Tel 33 0 1 61 37 2900 FAX 33 0 1 30 57 5427 Toll Free in France 0800 466 342 e mail sales omega fr Servicing Europe U S A and Canada Sales Service 1 800 826 6342...

Page 3: ...mance To prevent electrical or fire hazard do not expose the unit to excessive moisture Do not operate the unit in the presence of flammable gases or fumes such an environment definetely constitutes a...

Page 4: ...The decoupling created between the circuits avoids pernicious effects on the output such as groundloopsorsignalleaks whichdistort the acquired data and are extremely difficulttoisolateonceintroducedin...

Page 5: ...euppersideof the instrument This terminal is placed in atransverseaxis differentfromtheother terminals Close to the power supply terminal there is a small yellow label with indicationsontheconnections...

Page 6: ...F RONT VIEW WITHOUT COVER SELECTIONJUMPERS OUTPUT SIGNAL SPANP OTENTIOMETER OFFSET POTENTIOMETER Selection Jumpers Input Signal Range See next page SELECTIONJUMPERS INPUT SIGNAL getting an output whic...

Page 7: ...NAL RANGE Range 100 FS Range 25 FS Range 50 FS Range 3 KOhms Range Min 1 5 KOhms Range 1 5 KOhms Range Min 750 Ohms Range 5 KOhms Range Min 3 KOhms Range 10 KOhms Range Min 5 KOhms DRF POT for POTENTI...

Page 8: ...DRF Series Input Connections POTENTIOMETER RESISTANCE 9mm 0 35 93mm 3 66 24 Vdc 0 Vdc 110 mm 4 33 DIMENSIONS AND CONNECTIONS Special Width for AC Power models AC Powered DC Powered Output Connections...

Page 9: ...Models DRF POT and DRF RES StandardDINrailmounting asspecified onDIN46277andDINEN50022 37 5 x 7 5 mm 1 38 x 0 3 GALVANICISOLATIONLEVELS DCUnits Input Output 3 5 KV 60 seconds Power Input 3 5 KV 60 se...

Page 10: ...l the unit far from elements generating electric noise or magnetic CAUTIONS WARNINGSANDNOTES fields such as power relays electrical engines speed regulators etc Do not use until installation is comple...

Page 11: ...per specification misapplication misuse or other operating conditions outside of OMEGA s control Components in which wear is not warranted include but are not limited to contact points fuses and triac...

Page 12: ...ty Indicators Turbine Paddlewheel Systems Totalizers Batch Controllers pH CONDUCTIVITY pH Electrodes Testers Accessories Benchtop Laboratory Meters Controllers Calibrators Simulators Pumps Industrial...

Reviews: