Omega Engineering DPG280 Series User Manual Download Page 3

UNRESTRICTED 

Please check the packaging and appearance after you received the product.

Please check the mode and specification of the product.

 

Keep correct electrical connection and

mounting method.

Please installation WITHOUT power.

During using, please notice the technical and operation conditions: the temperature of medium,
burst pressure, power supply.

This product is a precision device, DO NOT use hard objects to touch the diaphragm or
disassemble.

During installation, do not install or disassemble strongly, especially the installation of thread.

Please install or disassemble with a suitable wrench,

 

otherwise, the damage is not in the scope

 

of

warranty.

After starting the gauge, it is a normal phenomenon to take a few minutes to keep it stable and
work normally.

If the product is out of order, please contact our after-sale technical staff.

During installation, the gauge will be affected by installation stress. After installation, please zero
clearing.

(!!)The product damage caused by non-professional operation according to the operation
regulation is not

 

the scope by the warranty.

The DPG280 is shipped with 2 AAA batteries outside of the unit. To install or replace batteries, first 
remove the four screws. Then remove the lid using a flat head screwdriver and the two pry slots 
(shown above), as needed. 

CAUTION: Do not apply force to keypad area on the front of the unit when 
replacing the lid. Force should only be applied on the raised edges of the unit or 
areas that do not contain keypad buttons or the screen. 

NOTE: Battery operating and storage temperatures can vary by manufacturer. 
The temperature rating of the replacement batteries you choose may limit the temperature to a 
narrower range than specified for the DPG509. Please consult 
the battery manufacturer for temperature limitations. 

Battery life will vary based on the quality of batteries installed and combination of selected settings. 
Below are general guidelines to maximize battery life: 

Keep the backlight off or rarely use

Select a low sampling rate

Avoid prolonged exposure to extreme temperatures

1.1    Precautions

 

Section 1 

– Introduction

 

Summary of Contents for DPG280 Series

Page 1: ...e mail info omega com For latest product manuals omega com en us pdf manuals TM Shop online at omega com User sGuide Digital Pressure Gauge DPG280 SERIES ...

Page 2: ... Setup 2 1 General Dimensions 3 Section 3 Menu and Configuration 3 1 LCD and Code Description 3 3 2 Button Functionality 4 3 3 Adjust of Filter Constant 4 3 4 Power 4 3 5 Data Record 4 3 6 Peak Value 5 3 7 Troubleshooting 5 Section 4 Software Instructions 4 1 Software Instructions 6 ...

Page 3: ...g The product damage caused by non professional operation according to the operation regulation is not the scope by the warranty The DPG280 is shipped with 2 AAA batteries outside of the unit To install or replace batteries first remove the four screws Then remove the lid using a flat head screwdriver and the two pry slots shown above as needed CAUTION Do not apply force to keypad area on the fron...

Page 4: ... MAX MIN Max Min Pressure Battery Level Percent Communication Sign E E Abnormal sensor communication or sensor damage E H Current Pressure Over Range Use or Sensor Damage E P Enter pressure calibration procedure please power off and exit P C Enter Temperature Compensation Procedure Please Turn Off and Exit r 03 Filter constant setting Section 2 Setup ...

Page 5: ... Power BATTERY Two AAA battery 3 5 Data Record 1 On off data record function After power short press back light button then the pressure unit sign begin to flicker it means the data record function is open Press back light button again then the pressure unit sign stop flickering it means the data record function is closed 2 Adjustment the record interval time Long press back light button for 3 sec...

Page 6: ...uestion Pressure no change Answer Reason Analysis 1 Pressure port is block 2 Zero clearing with pressure applied 3 Pressure sensor damage Solutions 1 Clear pressure connector 2 Zero clearing without pressure 3 Return factory for repair 4 Question Showing E H Answer Reason Analysis 1 Over pressure 2 Pressure sensor is damaged Solutions 1 Decrease pressure 2 Return factory for repair 5 Question Pres...

Page 7: ...art the application dot net Framework 4 8 should be install if the software cannot start This installation has been placed in the drivers folder 2 Click the search button to list the connected pressure gauge See the Driver install section if no device found Section 4 Software Instructions 4 1 Software Instructions ⅰQuick start ...

Page 8: ...RESTRICTED 4 Drag the data chart to zoom in the curve right click to zoom out 5 Click the Export button to export the history data 3 Select the unit and click download button to start the download process ...

Page 9: ...d select update driver Click Browse this computer to find the driver Select the Drivers CH341SER folder and click OK to install the driver 6 Click the Clear button to clear the history data in gauge ⅱ Diver install 1 Right click the This computer and select manager ...

Page 10: ...f its products in accordance with information provided by OMEGA either verbal or written OMEGA warrants only that the parts manufactured by the company will be as specified and free of defects OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER EXPRESSED OR IMPLIED EXCEPT THAT OF TITLE AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PART...

Page 11: ...elative to the product OMEGA s policy is to make running changes not model changes whenever an improvement is possible This affords our customers the latest in technology and engineering OMEGA is a trademark of OMEGA ENGINEERING INC Copyright 2018 OMEGA ENGINEERING INC All rights reserved This document may not be copied photocopied reproduced translated or reduced to any electronic medium or machi...

Reviews: