Omega Engineering DIN-RAIL DRN-PS-750 Operator'S Manual Download Page 2

Servicing North America:

USA:

One Omega Drive, P.O. Box 4047

ISO 9001 Certified

Stamford, CT 06907-0047
TEL: (203) 359-1660

FAX: (203) 359-7700

e-mail: [email protected]

Canada:

976 Bergar
Laval (Quebec) H7L 5A1
TEL: (514) 856-6928

FAX: (514) 856-6886

e-mail: [email protected]

For immediate technical or application assistance:

USA and Canada:

Sales Service: 1-800-826-6342 / 1-800-TC-OMEGA

¨

Customer Service: 1-800-622-2378 / 1-800-622-BEST

¨

Engineering Service: 1-800-872-9436 / 1-800-USA-WHEN

¨

TELEX: 996404   EASYLINK: 62968934   CABLE: OMEGA

Mexico

TEL: (001)800-TC-OMEGA

SM

FAX: (001) 203-359-7807 

En Espa–ol: (001) 203-359-7803

e-mail: [email protected]

Servicing Europe:

Benelux:

Postbus 8034, 1180 LA Amstelveen, The Netherlands
TEL: +31 (0)20 6418405

FAX: +31 (0)20 6434643

Toll Free in Benelux: 0800 0993344
e-mail: [email protected]

Czech Republic:

RudŽ arm‡dy 1868, 733 01 Karvin‡ 8
TEL: +420 (0)69 6311899

FAX: +420 (0)69 6311114

e-mail: [email protected]

France:

9, rue Denis Papin, 78190 Trappes
TEL: +33 (0)130 621 400

FAX: +33 (0)130 699 120

Toll Free in France: 0800406342
e-mail: [email protected]

Germany/Austria:

Daimlerstrasse 26, D-75392 Deckenpfronn, Germany
TEL: +49 (0)7056 9398-0

FAX: +49 (0)7056 9398-29

Toll Free in Germany: 0800 TC-OMEGA

SM

e-mail: [email protected]

United Kingdom:

One Omega Drive

ISO 9002 Certified

River Bend Technology Centre
Northbank, Irlam
Manchester M44 5EX United Kingdom
TEL: +44 (0)161 777 6611

FAX: +44 (0)161 777 6622

Toll Free in the UK: 0800 488 488
e-mail: [email protected]

OMEGAnet

SM

On-Line Service 

Internet e-mail

http://www.omega.com [email protected]

It is the policy of OMEGA to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly
pursuing certification of its products to the European New Approach Directives. OMEGA will add the CE mark to every
appropriate device upon certification.
The information contained in this document is believed to be correct but OMEGA Engineering, Inc. accepts no liability
for any errors it contains, and reserves the right to alter specifications without notice.

WARNING: 

These products are not designed for use in, and should not be used for, patient connected applications.

This device is marked with the international caution symbol.   It is important to read the Setup Guide before installing or
commissioning this device as it contains important information relating to safety and EMC.

Summary of Contents for DIN-RAIL DRN-PS-750

Page 1: ......

Page 2: ...sse 26 D 75392 Deckenpfronn Germany TEL 49 0 7056 9398 0 FAX 49 0 7056 9398 29 Toll Free in Germany 0800 TC OMEGASM e mail germany omega com United Kingdom One Omega Drive ISO 9002 Certified River Ben...

Page 3: ...ounting 5 4 Temperature Ranges 5 5 Input Range 5 6 Input Current Surge Protection 5 7 Output Voltage 5 8 Output Current 5 9 Output Ripple 5 10 Temperature Derating 5 11 Power on Indicator 5 12 Short c...

Page 4: ...ammability rating Glass filled polycarbonate case UL 94VO Recessed live parts and connector screws Either 32mm or 35mm DIN rail mounting Jumper select 230V 50Hz or 115V 60Hz input Wide input voltage t...

Page 5: ...C 348 Exceeds VDE551 IEC 742 separation spacing Exceeds VDE106 protective separation Exceeds VDE 160 clearance distances Exceeds VDE160 creepage distances 2 3 Protective Classes IEC 529 IP 20 VDE 106...

Page 6: ...is to be transported then disconnection dismounting and separate packing of the power supply is recommended For units that must be shipped installed on the rail additional bracing to resist transporta...

Page 7: ...it in front of you the same way as shown in Figure 3 1 on the following page 3 On the main board locate the transformer jumpers W1 W2 and W3 near the transformer T1 If your power requirement is 115Vac...

Page 8: ...Board Power Jumpers MAIN BOARD T1 115VAC WIRING SHOWN WITH W1 W3 TRANSFORMER MOUNTING PLATE W2 115VAC JUMPER WIRING W1 W3 W2 230VAC JUMPER WIRING W2 W3 W1 INSTALLATION AND REMOVAL 3 6 DRN PS DIN Rail...

Page 9: ...unting rail guide on the top edge of the mounting rail and lower it to lock it into position Removal Release the spring catch with a screwdriver while raising the module to disengage it installation r...

Page 10: ...4 1 Front Panel Connection Labels shown without regulator cover AC Line AC Neutral Ground RETURN NO CONNECTION 21 5V IN AC N PWR V N C OUT DC INPUT AND OUTPUT CONNECTIONS 4 8 DRN PS DIN Rail Power Su...

Page 11: ...ght Height 2 76 70mm Width 2 95 75mm Depth 5 95 151mm Weight 2 0 lbs 0 9 kg 5 3 Mounting 35mm top hat DIN EN 50022 5 4 Temperature Ranges Operating Temperature Ranges 20 to 60 degrees C Storage Temper...

Page 12: ...5 6 Input Current Surge Protection 6kA 275V Varistor 5 7 Output Voltage 21 5V 2 IR where I output current amperes and R 0 3 5 8 Output Current DRN PS 750 0 750mA 5 9 Output Ripple Less than 10mV pp S...

Page 13: ...Front Panel red LED lamp 5 12 Short circuit and overload protection DRN PS 750 foldback current limiting with automatic high temperature shutdown no fuses required 5 13 Wire Connections Screw down wi...

Page 14: ...5 230vac INPUT V Ground AC Line AC Neutral V A R I S T O R L C F I L T E R B R I D G E 21 5V R E G U L A T O R Return 75mA 50 DRN PS 750 C Ambient 0 1000 800 600 400 200 60 45 35 25 15 5 5 I max DERAT...

Page 15: ...Figure 8 1 Dimensions SPACED AS SHOWN POWER SUPPLY WITH 151 1 5 95 2 76 2 95 3 15 TWO SCREWS FASTEN RAIL UNDER MAX 70 0 75 0 80 0 DIMENSIONS DRAWING 8 13 DRN PS DIN Rail Power Supplies...

Page 16: ...inst excessive energy being drawn from the mains supply in case of a fault in the equipment an overcurrent protection device shall be installed The Protective Conductor must be connected for safety re...

Page 17: ...special damages CONDITIONS Equipment sold by OMEGA is not intended to be used nor shall it be used 1 as a Basic Component under 10 CFR 21 NRC used in or with any nuclear installation or activity or 2...

Page 18: ...M U Totalizers Batch Controllers pH CONDUCTIVITY M U pH Electrodes Testers Accessories M U Benchtop Laboratory Meters M U Controllers Calibrators Simulators Pumps M U Industrial pH Conductivity Equip...

Reviews: