background image

 

 

OMEGA ALTISE 

 

 

IMPORTANT SAFETY INSTRUCTIONS 

 

 

IMPORTANT

:

 

Read the safety precautions of this booklet carefully before attempting to assemble, install, operate or 

maintain the product described.  Protect yourself and others by observing all safety information.  Failure 

to comply with instructions could result in personal injury and/or property damage.  If you are unsure 

about anything regarding your fan or these instructions, please contact Omega Altise on 1300 795 572 in 

Australia or (09) 415 6000 in New Zealand before operating your appliance

 

 

This unit is not intended for use by children or infirm person without supervision. 

 

WARNING: 

  

The Function Switch should not be used as the sole means of disconnecting 

power. Always unplug the power cord before servicing or moving the appliance.   

 

 

The A-weighted sound pressure level is below 51 db. 

 

The appliance shall be disconnected from its power source during service. 

 

Always operate the unit from a power source of equal voltage, frequency and rating as indicated on 

the product identification plate. 

 

Always use a power outlet that is grounded. 

 

Do not operate with wet hands. Prevent water from spilling onto the unit. 

 

Do not immerse or expose the unit to rain, moisture or any other liquid. 

 

Do not leave the unit running unattended. Do not tilt or turn over the unit. 

 

Do not unplug while the unit is operating. 

 

Do not use an extension cord or an adapter plug. 

 

Do not put objects on the unit. 

 

Do not climb or sit on the unit. 

 

Do not insert fingers or other objects into the air outlet. 

 

Do not touch the air inlet or the aluminum fins of the unit. 

 

Do not operate the unit if it is dropped, damaged or showing signs of product malfunction. 

 

Do not clean the appliance with any chemicals.  

 

Ensure the unit is far away from fire, inflammable, or explosive objects. 

 

The unit shall be installed in accordance with national wiring regulations. 

 

The appliance shall be stored in a room without continuously operation sources (for example: open 

flames, an operating gas appliance or an operating electric heater). 

 

The appliance shall be stored so as to prevent mechanical damage from occurring. 

 

Do not piece or burn, even after use. 

 

Be aware that refrigerants may not contain an odour. 

 

Pipework shall be protected from physical damage and shall not be installed in an unventilated space, if 

that space is smaller than 12 m². 

 

Keep any required ventilation openings clear of obstruction. 

 

Any person who is involved with working on or breaking into a refrigerant circuit should hold a current 

valid certificate from an industry-accredited assessment authority, which authorizes their competence 

to handle refrigerants safely in accordance with an industry, recognized assessment specification. 

 

Servicing shall only be performed as recommended by the equipment manufacturer. Maintenance and 

repair requiring the assistance of other skilled personnel shall be carried out under the supervision of 

the person competent in the use of flammable refrigerants. 

 

The appliance shall be stored in a well-ventilated area where the room size corresponds to the room 

area as specified for operation. 

 

 

 

WARINNG:   To avoid danger of electric shock, unplug from outlet when not in use and before 

cleaning. If the supply cord is damaged, it must be replaced by the manufacturer, its 

Service Agent or similarly qualified persons in order to avoid a hazard.  In order to avoid 

overheating, do not cover the appliance. Do not use the appliance in the immediate 

surrounding of a bath, shower or swimming pool. 

 

Summary of Contents for OAPC41W

Page 1: ...OMEGA ALTISE OPERATION MAINTENANCE AND SAFETY INSTRUCTIONS FOR OMEGA ALTISE AIR CONDITIONER Model OAPC41W...

Page 2: ...LTISE Contents IMPORTANT SAFETY INSTRUCTIONS 3 TECHNICAL DETAILS 8 FEATURES 9 PRODUCT OVERVIEW 9 INSTALLATION INSTRUCTIONS 10 OPERATING INSTRUCTIONS 14 CLEANING 18 SERVICING 20 TROUBLESHOOTING 22 WARR...

Page 3: ...gns of product malfunction Do not clean the appliance with any chemicals Ensure the unit is far away from fire inflammable or explosive objects The unit shall be installed in accordance with national...

Page 4: ...e shall be stored in a well ventilated area where the room size corresponds to the room area as specified for operation WARNING Do not use means to accelerate the defrosting process or to clean other...

Page 5: ...om a leak Cabling Check that cabling will not be subject to wear corrosion excessive pressure vibration sharp edges or any other adverse environmental effects The check shall also take into account th...

Page 6: ...lowed Ensure that contamination of different refrigerants does not occur when using charging equipment Hoses or lines shall be as short as possible to minimize the amount of refrigerant contained in t...

Page 7: ...omplete with pressure relief valve and associated shut off valves in good working order Empty recovery cylinders are evacuated and if possible cooled before recovery occurs The recovery equipment shal...

Page 8: ...ion systems or contact the retailer where the product was purchased They can take this product for environmentally safe recycling TECHNICAL DETAILS Model OAPC41W Fan Speeds 3 settings Cooling Capacity...

Page 9: ...shut off when tank full Automatic restart in the event of power outage Auto defrosting function at low ambient temperatures Remote control 3 speed fan Casters for easy mobility PRODUCT OVERVIEW 1 Cont...

Page 10: ...S Unpacking Unpack the carton and take the appliance and accessories out Check the device after unpacking for any damage or scratches on it Accessories 1 Exhaust hose 2 Hose connector 3 Window kit ada...

Page 11: ...radiators heat registers stoves or other products that produce heat II Direct sunlight III Mechanical vibration or shock IV Excessive dust V Lack of ventilation such as cabinet or bookcase VI Uneven...

Page 12: ...kit the length of your window Connect the exhaust hose to the window kit Step 4 Close your window to secure the kit in place It needs to hold the windows kit firmly in place secure the window kit wit...

Page 13: ...the hose connector to the exhaust air outlet of unit Step 6 Adjusting the length of the flexible exhaust hose and avoid bends in the hose Then place AC near an electrical outlet Step 7 Adjust the lou...

Page 14: ...Increasing the desired temperature 16 32 or timer setting 5 SWING Adjust the air flow direction vertically 6 TIMER Sets a time for the unit to automatically start or stop 7 FAN Press to switch the fa...

Page 15: ...tional on the remote control COOLING MODE Select the cool mode to lower the temperature in your room Press MODE button repeatedly until the LED of COOL operation lights up Press ADD MINUS button to ad...

Page 16: ...e control the LED of DRY operation lights up The fan speed is unable to select User should connect the hose to the drain outlet at the bottom of the unit Note In this mode the fan speed switches over...

Page 17: ...e self evaporating system uses the collected water to cool the condenser coils for better efficient performance There is no need to empty the drainage tank in cooling operation except in drying operat...

Page 18: ...cleaning The air filter is removable for easy cleaning Do not operate the unit without an air filter or the evaporator may be contaminated 1 Press POWER button to switch off the unit and unplug the po...

Page 19: ...on equipment PPE 4 Evacuate unnecessary personnel isolate and ventilate area 5 Do not get in eyes on skin or on clothing Do not breathe vapours or gas 6 Prevent entry to sewers and public waters 7 Sto...

Page 20: ...n system which involves exposing any pipe work that contains or has contained flammable refrigerant shall use any sources of ignition in such a manner that it may lead to the risk of fire or explosion...

Page 21: ...e safety then no electrical supply shall be connected to the circuit until it is satisfactorily dealt with If the fault cannot be corrected immediately but it is necessary to continue operation an ade...

Page 22: ...re transport Check if the drain hose is kinked or bends Straighten the hose to avoid a trap existing Excessive Noise Check if the unit is securely positioned Place the unit on horizontal and firm grou...

Page 23: ...ed to a warranty of Twelve 12 months covering all parts with Three 3 months on any labour cost of service or repair WHAT IS COVERED By Our Warranty During the warranty period Omega Altise or its autho...

Page 24: ...OMEGA ALTISE A division of Shriro Australia Pty Ltd 2 34 Davidson Street Chullora NSW 2190 In Australia 1300 795 572 In New Zealand 09 415 6000 www omegaaltise com IM Ref OAPC41W 2021 09 02 24...

Reviews: