BF - Installation and operating manual
7
Eventual over-pressure and over-temperature could be dangerous and hazardous to the
operator and the equipment.
DANGER
due to the release of a critical gas!
The release of a critical (Fluid group 1) gas from the network can constitute a
considerable risk for man and environment.
INSTALATION INSTRUCTIONS
•
The permissible working temperatures and pressures for ad-on parts and filter
elements are given under Technical data for those ad-ons. The maximum
temperature and pressure for the assembled system are the lowest of any individual
part.
•
Install suitable safety devices, such as safety valves, rupture discs or safety related
measurement control and regulation devices, which ensure that the permissible
operating value limits are not exceeded.
•
It is necessary to ensure that the unit is equipped with the corresponding safety and
test devices to prevent the permissible operating parameters from being exceeded.
•
Ensure that the filter is not subject to vibrations that could cause fatigue fractures.
•
A filter is not to be subjected to mechanical stresses.
•
Depressurize the system before carrying out the installation work.
•
Connect inline and outline pipe to the filter, see instruction on picture 1 and 2 on
page 8. The filter housing and the system connections and accessory outlets must be
leak tight.
•
When connecting a pipe to the filter, take care that no dirt or foreign bodies or
liquids enter the filter, the direction of flow IN
–
OUT is adhered to.
•
Install the filter vertically and in such a way that the condensate exit is below.
•
The filter must be installed with a minimum distance to the ground in relation to the
height of the filter elements used and plus 50mm allowance, for easy replacement
the filter elements. (The height of the filter elements is specified in the data-sheet of
the filter elements).
•
A pressure gauge, which shows the operational pressure, must be installed in the
unit, respectively in the pipeline.
•
The unit must be installed vertically in the piping.
•
Install the pressure equipment in such a way that it is accessible for the possibly
inspections and can be viewed from all sides.
•
Install appropriate fittings (e.g.: non-
return valves, pressure maintaining valves, …) to
avoid that the filter is subjected to unauthorized alternating stress.
•
Wherever possible, installation of the filter housing should be made using an
appropriate mounting bracket to avoid excessive loads on the piping.
•
For install a drain condensate device see instructions and operating manual for
condensate, the manual are attached to the condensate drain device.