BF - Installation and operating manual
10
Filter elements are subject to wear. In order to maintain system efficiency, optimal
performance and best air quality, these rules of proper maintenance should be followed:
INSTRUCTION FOR REGULAR CHECKS
•
Once per year make a visual check of filter housing and make sure there is no visual
damage.
•
If installed, weekly check the pressure drop indicator to ensure the filter element is
not saturated, and pressure drop is within acceptable limits.
•
If installed, ensure a trouble-free operation of the condensate drain. Check at least
once a week if condensate drain operates regularly.
•
The filter has been primarily designed for a life of 10 years in a normal operating
environment. For safe operation and respect local law regularly checks the filter
according to local regulations.
MAINTENANCE
•
Never use unsuitable tools to open and close the filter housing
•
Replace filter elements, as stated in the filter element product data-sheet, which you
get attached to the filter elements.
•
B filter element can be cleaned with ultrasonic bath or with back flushing. Intervals of
cleaning depend on the application. If necessary replace filter element with new one.
•
The housing O-ring can be damaged during filter element change. To prevent air
leakage and malfunction replace housing O-ring if necessary.
•
Carry out a check for leaks once the maintenance work has been finished.
•
Damaged components are to be replaced by new ones. If a marked degree of
damage is found, the entire filter is to be replaced.
Disposing of filter elements:
The filter element or catridge might be contaminated by the filtered substances. Heed the
notes on hazardous substances for the filtered gas and appropriate disposal regulations
when disposing.