3
Technical data
FILTER
SET
PIPE SIZE
[inch]
FILTER
ELEMENT
FLOW CAPACITY
DIMENSIONS [mm]
VOLUME
[l]
WEIGHT
[kg]
[Nm
3
/h] [scfm]
A
B
C
D
B-AIR 0076
/ ”
07050 (XS+H
2
+A
2
)
78
46
190
88
21
60
3x0,45
2,8
B-AIR 0106
/ ”
14050 (XS+H
2
+A
2
)
120
70
260
88
21
130
3x0,64
2,9
B-AIR 0186
”
12075 (XS+H
2
+A
2
)
198
116
262 125 37
130
3x1,4
7,5
B-AIR 0306
”
22075 (XS+H
2
+A
2
)
335
197
362 125 37
220
3x 2,0
8,7
B-AIR 0476
½”
32075 (XS+H
2
+A
2
)
510
300
462 125 37
320
3x 2,6
9,6
B-AIR 0706
½”
50075 (XS+H
2
+A
2
)
780
459
642 125 37
500
3x 3,6
11,8
Flow capacity at bar(g), 0°C
MATERIALS
Housing material
Aluminum
Fittings, Screws
Brass, Brass-zinc plated, Steel
Cover
ABS
Sealing
NBR
Corrosion protection
Electrophoretic Coating (KTL)
Outside protection
Powder paint coated (Epoxi-polyester base)
Lubricant
Shell cassida grease RLS 2
Filter media
Borosilicate micro fibres
Support
Stainless Steel 1.4301
CORRECTION FACTORS
To calculate the correct capacity of a given filter based on actual operating
conditions, multiply the nominal flow capacity by the appropriate correction
factor(s).
CORRECTED CAPACITY = NOMINAL FLOW CAPACITY x C
OP
OPERATING PRESSURE
[bar]
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
[psi]
29
44
58
72
87
100
115
130
145
160
174
189
203
218
232
C
OP
0,38
0,5
0,63 0,75 0,88
1
1,13 1,25 1,38 1,50 1,63 1,75 1,88 2,00 2,13
Operating temperature
1,5 - 4
°C
35 - 113
°F
Operating pressure
0 - 16 bar(g)
0 - 232 psi