9. Use and maintenance manual
B01.10-B01.12
San Maurizio C.se - 11/07/2018
www.omcr.it
4. HANDLING AND STORAGE
OMCR CODE
WEIGHT (kg)
B01.10.016
0,2
B01.10.020
0,3
B01.10.025
0,7
B01.10.032
1,1
B01.10.040
1,9
B01.10.050
3,2
B01.10.063
7,5
B01.10.080
14,8
B01.10.100
25,6
OMCR CODE
WEIGHT (kg)
B01.12.016
0,2
B01.12.020
0,3
B01.12.025
0,8
B01.12.032
1,2
B01.12.040
2
B01.12.050
3,4
B01.12.063
7,8
B01.12.080
15,4
B01.12.100
26,5
4.2
If not used the lifting brackets must be stored far from wet and preserved from oxidation by appling
protective oil.
In the following table are written OMCR B01.10 - B01.12. lifting brackets weights;
the
lifting brackets must be handled in compliance with the current norms concerning
the movement by hand of the loads.
WARNING
4.1
At the moment of the assembling, carefully clean the contact surfaces between lifting
brackets and steel plates.
The presence of oil or dirt on the contact surface between the lifting bracket and the mold
holder plate may compromise the correct functioning of the lifting bracket
WARNING
4.2.1
5. MAINTENANCE
5.1
Each 6 months make visual tests to check the presence of visible anomalies or beginning of oxidation: in
case restore or replace the lifting brackets.
5.2
Each 6 months make tests for the correct clamp of the fixing screws following the table indicated in this
manual.
5.3
In case of unforeseen settlements of lifting ropes/chains with a following overload on the lifting brackets,
make visual tests on the lifting brackets to check eventual deformations and, in case of these last ones, substitute
them; substitute the fixing screws and check the correct clamp following the table indicated in this manual.
5.4
In case of accidental impacts in the sling-zone during the lifting and handling, make visual tests on the
lifting brackets to check eventual deformations and, in case of these last ones, substitute them; substitute the
fixing screws and check the correct clamp following the table indicated in this manual.