background image

9. Use and maintenance manual 

B01.10-B01.12

San Maurizio C.se - 11/07/2018

www.omcr.it

4. HANDLING AND STORAGE

OMCR CODE

WEIGHT (kg)

B01.10.016

0,2

B01.10.020

0,3

B01.10.025

0,7

B01.10.032

1,1

B01.10.040

1,9

B01.10.050

3,2

B01.10.063

7,5

B01.10.080

14,8

B01.10.100

25,6

OMCR CODE

WEIGHT (kg)

B01.12.016

0,2

B01.12.020

0,3

B01.12.025

0,8

B01.12.032

1,2

B01.12.040

2

B01.12.050

3,4

B01.12.063

7,8

B01.12.080

15,4

B01.12.100

26,5

4.2

  If not used the lifting brackets must be stored far from wet and preserved from oxidation by appling 

protective oil.

In the following table are written OMCR B01.10 - B01.12. lifting brackets weights; 

the 

lifting brackets must be handled in compliance with the current norms concerning 
the movement by hand of the loads.

WARNING

4.1

At the moment of the assembling, carefully clean the contact surfaces between lifting 
brackets and steel plates.

The presence of oil or dirt on the contact surface between the lifting bracket and the mold 
holder plate may compromise the correct functioning of the lifting bracket

WARNING

4.2.1

5. MAINTENANCE

5.1 

Each 6 months make visual tests to check the presence of visible anomalies or beginning of oxidation: in 

case restore or replace the lifting brackets.

5.2

 Each 6 months make tests for the correct clamp of the fixing screws following the table indicated in this 

manual.

5.3 

In case of unforeseen settlements of lifting ropes/chains with a following overload on the lifting brackets, 

make visual tests on the lifting brackets to check eventual deformations and, in case of these last ones, substitute 
them; substitute the fixing screws and check the correct clamp following the table indicated in this manual.

5.4

 In case of accidental impacts in the sling-zone during the lifting and handling, make visual tests on the 

lifting brackets to check eventual deformations and, in case of these last ones, substitute them; substitute the 
fixing screws and check the correct clamp following the table indicated in this manual.

Summary of Contents for B01 10 016

Page 1: ...conformity declaration LIFTING BRACKET VDI3366 Item code B01 10 B01 12 San Maurizio C se 11 07 2018 www omcr it Via Quarantelli 8 10077 S Maurizio C se Italy T 39 011 996 46 11 F 39 011 996 46 46 C F...

Page 2: ...l B01 10 B01 12 San Maurizio C se 11 07 2018 www omcr it 1 Risks valuation 2 Symbols and warnings classification 3 Use 4 Handling and storage 5 Maintenance 6 EC conformity declaration pag 3 pag 3 pag...

Page 3: ...materials have been subjected to tensile stress test according to UNI EN 10002 Calculations and risk assessments have been made according to VW AUDI BMW MERCEDES BENZ VDI3366 norms An improper or opp...

Page 4: ...executed by qualified and instructed worker the lifting handling or turnover officers must use individual guard equipment WARNING 3 1 Before each lifting handling overturning officers have to choose t...

Page 5: ...escriptions included in this manual may cause the accidental fall of the load 3 2 2 The die overturning is not allowed see Pic 1 WARNING Pic 1 G Die load center Minimum rope angle from vertical 1 Maxi...

Page 6: ...any defect or deformation to make it unsafe in case eliminate immediately the defective parts WARNING 3 4 At the moment of the use check the correct screws clamping and the use of screws with the requ...

Page 7: ...rried out see Pic 3 WARNING 3 6 The missing respect of the prescriptions included in this manual may cause the accidental fall of the load WARNING OMCR CODE H mm B01 10 016 B01 12 016 6 B01 10 020 B01...

Page 8: ...the ropes chains are not hooked to the die corners WARNING 3 9 Don t stand or transit nearby the load during lifting or handling operations see Pic 6 In case of accidental release of the load there ma...

Page 9: ...dirt on the contact surface between the lifting bracket and the mold holder plate may compromise the correct functioning of the lifting bracket WARNING 4 2 1 5 MAINTENANCE 5 1 Each 6 months make visu...

Page 10: ...ponsible of the technical file acting in OMCR Via Quarantelli 8 10077 San Maurizio C se These procedures have been exactly issued to allow OMCR mark with EC symbol to ensure that these products are in...

Reviews: