![Omcan VP-NL-3016-SN Instruction Manual Download Page 13](http://html1.mh-extra.com/html/omcan/vp-nl-3016-sn/vp-nl-3016-sn_instruction-manual_4171245013.webp)
13
Operation
while the cover stays closed and the machine will turn off automatically after about 15 minutes.
- These cycles are necessary to cool down the machine and to allow any moisture in the oil of the pump to
evaporate.
TEN-PROGRAM CONTROL SYSTEM
• The Ten-Program control system is standard time-based on the M20, M40-M80, L01-L60.
- Sensor-based operation is an option, which can be installed at a later date.
• The Ten-Program control system provides:
- 9 customizable programs (P1-P9).
- Program PA; this is an - Automatic Program – Pre-set at the factory at a vacuum time of 30-40 seconds
(or 5 mbar for a sensor-based program) and a sealing time of 2 seconds.
• Program P H2O for liquid products.
- When turning on the machine, the pump will start. After about 15 minutes of inactivity, the pump will stop
automatically.
PROGRAMMABLE FUNCTIONS
The following functions may be customized for each program P1-P9:
Vacuum time:
in seconds or mbar (only with sensor).
Sealing time:
in seconds.
Vacuum Plus:
on/off, in seconds.
Gassing:
on/off, in seconds or mbar (only with sensor).
Clean Cut Controlled (CCC) Seal:
on/off, in seconds.
Soft-Air:
on/off, in seconds or mbar (only with sensor).
Multi-cycle:
on/off, in number of cycles.
REVIEWING FUNCTION VALUES FOR P1-P9
1. Turn the machine on by pushing the button.
2. The most-recently used program will be indicated.
3. All selected functions for this program are indicated at the bottom of the display.
4. To review the values for these functions, push the button; use the button to display each
function value.
5. The values cannot be changed; this can only be done in the Settings menu.
6. Push the button to return to the Home menu.
PROGRAMMING AND ADJUSTING VALUES FOR P1-P9
1. Select the program to be set up or adjusted.
2. Push the menu button to access the Settings menu.
3. All functions for the selected program are indicated at the bottom of the display.
4. Push the button to select the blinking function to be adjusted.
5. Adjust the value of the selected function with the button.
6. Press the button to reset all functions to their original values.
7. Select the next function with the button.
Summary of Contents for VP-NL-3016-SN
Page 21: ...21 Parts Breakdown Model VP NL 3016 SN 59011 Model VP NL 3008 SN 59012 Overall ...
Page 22: ...22 Parts Breakdown Model VP NL 3016 SN 59011 Model VP NL 3008 SN 59012 Vacuum Chamber ...
Page 23: ...23 Parts Breakdown Model VP NL 3016 SN 59011 Model VP NL 3008 SN 59012 Lid ...
Page 24: ...24 Parts Breakdown Model VP NL 3016 SN 59011 Model VP NL 3008 SN 59012 Hinge ...
Page 25: ...25 Parts Breakdown Model VP NL 3016 SN 59011 Model VP NL 3008 SN 59012 Air Valve ...
Page 26: ...26 Parts Breakdown Model VP NL 3016 SN 59011 Model VP NL 3008 SN 59012 Transformer ...
Page 27: ...27 Parts Breakdown Model VP NL 3016 SN 59011 Model VP NL 3008 SN 59012 Control Panel ...
Page 31: ...31 Parts Breakdown Model VP NL 0040 SN 59013 Overall ...
Page 32: ...32 Parts Breakdown Model VP NL 0040 SN 59013 Vacuum Chamber ...
Page 33: ...33 Parts Breakdown Model VP NL 0040 SN 59013 Seal Lid ...
Page 34: ...34 Parts Breakdown Model VP NL 0040 SN 59013 Hinge ...
Page 35: ...35 Parts Breakdown Model VP NL 0040 SN 59013 Air Valve ...
Page 36: ...36 Parts Breakdown Model VP NL 0040 SN 59013 Transformer ...
Page 37: ...37 Parts Breakdown Model VP NL 0040 SN 59013 Control Panel ...
Page 41: ...41 Parts Breakdown Overall Model VP NL 0050 SN 59014 ...
Page 42: ...42 Parts Breakdown Model VP NL 0050 SN 59014 Vacuum Chamber ...
Page 43: ...43 Parts Breakdown Seal Lid Model VP NL 0050 SN 59014 ...
Page 44: ...44 Parts Breakdown Model VP NL 0050 SN 59014 Hinge ...
Page 45: ...45 Parts Breakdown Model VP NL 0050 SN 59014 Air Valve ...
Page 46: ...46 Parts Breakdown Model VP NL 0050 SN 59014 Switch Box ...
Page 47: ...47 Parts Breakdown Model VP NL 0050 SN 59014 Control Panel ...
Page 51: ...51 Electrical Schematics Model VP NL 3016 SN 59011 Model VP NL 3008 SN 59012 ...
Page 52: ...52 Electrical Schematics Model VP NL 0040 SN 59013 ...
Page 53: ...53 Electrical Schematics Model VP NL 0050 SN 59014 ...