![Omcan VP-NL-0100-L Instruction Manual Download Page 19](http://html1.mh-extra.com/html/omcan/vp-nl-0100-l/vp-nl-0100-l_instruction-manual_4171051019.webp)
19
Troubleshooting
Fault/Symptom
Possible Cause
Remedy
Machine does not work.
The machine is not plugged in.
Plug the machine into the electrical
outlet.
The ground fault safety in the
electrical panel has tripped.
Check the electrical panel.
A fuse in the electrical panel is
faulty.
Check the electrical panel.
A fuse in the machine is faulty.
Consult your dealer.
The motor protection of the
machine is switched off.
Consult your dealer.
The vacuum pump does not run at
full speed.
The oil is too thick or
contaminated.
Change the oil.
The pump motor runs on two
phases.
Check the voltage; if correct,
consult your dealer.
The vacuum in the package is
insufficient.
The programmed vacuum value is
too high.
Lower the vacuum value in the
program.
The packaging material is of poor
quality.
Select a better-quality packaging
material.
The product damages the bag.
Program a higher value for Soft-
Air.
The machine gases the package.
Turn off the gassing function.
The seal is leaking.
The package seam is poorly
formed.
Increase the sealing time and/or
reduce the MAP gas pressure.
The package seam is burnt.
Decrease the sealing time.
The opening of the vacuum bag is
contaminated.
Try again and make sure that the
opening of the bag stays clean.
The sealing beam is dirty.
Clean the sealing beam.
The Teflon lining of the sealing
beam is damaged.
Replace the Teflon lining.
The silicon rubber seal in the
counter beam is damaged.
Replace the silicon rubber seal.
There is not enough gas in the
bag.
The bag is too small.
Select a bigger bag.
The programmed gas level is too
low.
Increase the gas level value.
The bag is not correctly positioned
over the gas outlets.
Adjust the bag position.
Summary of Contents for VP-NL-0100-L
Page 21: ...21 Parts Breakdown Model VP NL 0100 L 50000 Lid ...
Page 22: ...22 Parts Breakdown Model VP NL 0100 L 50000 Workplate ...
Page 23: ...23 Parts Breakdown Model VP NL 0100 L 50000 Standard Assembly ...
Page 24: ...24 Parts Breakdown Model VP NL 0100 L 50000 Switch Box ...
Page 25: ...25 Parts Breakdown Model VP NL 0100 L 50000 Vacuum Gas Pump ...
Page 29: ...29 Parts Breakdown Model VP NL 0300 L 50001 Lid ...
Page 30: ...30 Parts Breakdown Workplate Model VP NL 0300 L 50001 ...
Page 31: ...31 Parts Breakdown Standard Assembly Model VP NL 0300 L 50001 ...