Operation
When turning off the machine with the button, the symbol will start blinking on the
LCD display:
•
The pump will stop after about 4 seconds.
•
Press the button for a second time and the pump will stop immediately.
•
Close the lid; the machine will initiate the cool-down phase and perform a number of vacuum
cycles before turning off automatically.
•
These additional cycles allow any moisture in the oil of the pump to evaporate. This increases
the longevity of the machine and minimizes the need for oil changes and pump maintenance.
Service Symbol:
•
After reaching a certain number of operating hours or packing cycles, the service symbol will
briefly appear on the display when turning on the machine. In addition, the display indicates
how many hours or cycles remain before
• Except for regularly changing the oil in the pump, the machine requires little other routine
maintenance.
•
After reaching the service limit, the display will indicate the negative number of exceeded
operating hours or cycles.
• To reset the service interval counters after the oil change: Start machine and while the
display shows the hours or cycles, press and hold the button to reset.
PROGRAMMING THE MACHINE
TEN-PROGRAM CONTROL SYSTEM
•
The Ten-Program control system is standard time-based on the M20, M40-M80, L01-L60.
option, which can be installed at a later date.
• The Ten-Program control system provides:
- 9 customizable programs (P1-P9).
- Program PA; this is
- Automatic Program – Pre-set at the factory at a vacuum time of 30-40 seconds
(or 5 mbar for a sensor-based program) and a sealing time of 2 seconds.
• Program P H2O for liquid products.
- When turning on the machine, the pump will start. After about 15 minutes of inactivity, the pump will stop
automatically.
PROGRAMMABLE FUNCTIONS
The following functions may be customized for each program P1-P9:
Vacuum time:
in seconds or mbar (only with sensor).
Sealing time:
in seconds.
Vacuum Plus:
on/off, in seconds.
Gassing:
on/off, in seconds or mbar (only with sensor).
Clean Cut Controlled (CCC) Seal:
on/off, in seconds.
Soft-Air:
on/off, in seconds or mbar (only with sensor).
Multi-cycle:
on/off, in number of cycles.
Summary of Contents for VP-NL-0050-LS
Page 17: ...17 Parts Breakdown Model VP NL 0050 LS 45310 Vacuum Pump...
Page 18: ...18 Parts Breakdown Model VP NL 0050 LS 45310 Worktable...
Page 19: ...19 Lid Parts Breakdown Model VP NL 0050 LS 45310...
Page 20: ...20 Parts Breakdown Model VP NL 0050 LS 45310 Seal Bar...
Page 21: ...21 Parts Breakdown Model VP NL 0050 LS 45310 Vacuum Valve...
Page 22: ...22 Parts Breakdown Model VP NL 0050 LS 45310 Switch Box...
Page 23: ...23 Parts Breakdown Model VP NL 0050 LS 45310 Control Panel...
Page 28: ...28 Electrical Schematics Model VP NL 0050 LS 45310...